HDU45-C-20

Description
DC-DC CONVERTER 19" COMPATIBLE EUROCARD MULTI-OUTPUT DC-DC CONVERTER 19" COMPATIBLE EUROCARD MULTI-OUTPUT
File Size294KB,4 Pages
ManufacturerHitron
Websitehttp://www.hitron-e.com/
Download Datasheet View All

HDU45-C-20 Overview

DC-DC CONVERTER 19" COMPATIBLE EUROCARD MULTI-OUTPUT DC-DC CONVERTER 19" COMPATIBLE EUROCARD MULTI-OUTPUT

H HiTRON
DC-DC CONVERTER 19" COMPATIBLE EUROCARD MULTI-OUTPUT
45-100 WATTS SWITCHING MODE POWER SUPPLIES
HDU45, HDU60 & HDU100 SERIES
FEATURES:
12/24/48VDC INPUT RANGE
19" COMPATIBLE EUROCARD FORMAT
EMI MEET CISPR PUB. 22 & FCC CLASS B
MEET THE SAFETY STANDARDS
CE MARKING COMPLIANCE
HDU45 3UX6HPX160MM VMEbus STANDARD
HDU60 3UX8HPX160MM VMEbus STANDARD
HDU100 3UX10HPX160MM VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Three ranges option.
A Range: 9-18Vdc nominal 12Vdc.
B Range: 18-36Vdc nominal 24Vdc.
C Range: 36-72Vdc nominal 48Vdc.
Input Connector:
DIN 41612 at rear.
Input Current:
HDU45-A: 8.0A,HDU45-B: 4.0A,HDU45-C: 2.5A.
HDU60-A: 10.0A,HDU60-B: 5.0A,HDU60-C: 3.15A.
HDU100-A: 15.0A,HDU100-B: 6.3A,HDU100-C: 4.0A.
Dielectric Withstand:
Meet IEC 60950-1.
EMI:
Meet CISPR PUB. 22 & FCC Class B.
Power Fail Signal:
Installed.
Remote (Logic) Inhibit:
Installed.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
Typ. 45 Watts for HDU45.
Typ. 60 Watts for HDU60.
Typ. 100 Watts for HDU100.
Output Connector:
DIN 41612 at rear.
Line Regulation:
Typ. 0.4%.
Load Regulation:
Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±2-3.0%(PR).
± 2.0%(Mag. Amp.)
Aux. VO3 typ. ±2-3.0% (PR).
Aux. VO4 typ. ±2-3.0%(PR).
Noise & Ripple:
Typ. 1% peak to peak.
OVP:
Built-in at main VO1 (latch).
Adjustability:
Available at main output VO1 and
Aux. Output VO2 (Mag. Amp.).
Remote Sense:
Available at HDU60 & 100 single O/P.
Overload Protection (OLP):
Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency:
Typ. 70.0-75.0%.
Switching Frequency:
Typ. 100K Hz.
Circuit Topology:
Forward circuit.
Transient Response:
Typ. 3mS following a 25%
load change.
Power Density:
1.4 Watts / Cubic Inch for HDU45, HDU60.
1.9 Watts /Cubic Inch for HDU100.
Operating Temperature:
0 to +50°C at full load.
Derates linearly to +70°C at half load.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
Typ. 0.04% /°C.
Cooling:
Free air convection.
Construction:
6,8,10 HP(TE)x3Ux160mm 19" compatible
Eurocard VMEbus standard.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
-63-
Design Considerations for Intermittent and Continuous Duty Motor Circuit Protection
During normal operation, motors and actuators may experience overcurrent and overheating damage due to electrical shorts or circuit overloads. Both intermittent and continuous operation motors can ben...
jek9528 Industrial Control Electronics
Comparison of AC and DC measurement methods for low-power nanotechnology and other sensitive devices - DC reversal monitoring method 1
The DC reversal method [1] uses a DC source with reversible polarity and the response of the test object is measured using a nanovoltmeter.In the past, DC reversal monitoring required manual operation...
Jack_ma Test/Measurement
Verilog code, what is the problem, newbie help, waiting online
[i=s]This post was last edited by zhaironghui on 2015-10-22 11:26[/i] Hi everyone, I have just started to use Verilog and I have encountered a problem. I would like to ask for your advice. Thank you. ...
zhaironghui FPGA/CPLD
My progress on two small projects based on TI M3
Recently, I have built two TI M3-based devices in the school laboratory, one is an LC meter and the other is a CNC constant current source. The control part is first completed using the 8962 evaluatio...
熊猫 Microcontroller MCU
Could you please give me some advice, can the following circuit be established? What is the reason why it cannot be established?
[img]http://images22.51.com/6000/tf_digital/87d285dd879de62385f561622f9df420.jpg[/img] [img] The circuit is drawn by myself, and my personal analysis is as follows. I hope you can correct me if there ...
xiong8707 Embedded System
Comment to win a 50-yuan Jingdong card! Watch the video to learn how to use a mixed signal oscilloscope to explore bus and protocol analysis
The excellent design of the MSO6B series is oriented towards higher-speed embedded designs, meeting users' needs for mixed-signal design debugging and the ever-increasing serial bus speed. Provide cut...
EEWORLD社区 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2193  1840  2608  2626  2373  45  38  53  48  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号