EEWORLDEEWORLDEEWORLD

Part Number

Search

LMZ1601-7PV0AHF

Description
AC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid
CategoryPower/power management    The power supply circuit   
File Size150KB,4 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LMZ1601-7PV0AHF Overview

AC-DC Regulated Power Supply Module, 1 Output, 50W, Hybrid

LMZ1601-7PV0AHF Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-XXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage24.144 V
Minimum output voltage23.856 V
Nominal output voltage24 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output50 W
Fine-tuning/adjustable outputNO
Base Number Matches1
M Series
50 Watt AC-DC Converters
Input voltage range 85...264 V AC
1, 2 or 3 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
LGA
• Rugged electrical and mechanical design
• Outputs individually controlled with excellent
dynamic properties
• Operating ambient temperature range
–40...71°C with convection cooling
Selection chart
Output 1
U
o nom
I
o nom
[V DC] [A]
5.1
8
5.1
8
12
4
12
4
15
3.4
15
3.4
24
2
24
2
48
1
48
1
12
2
12
2
15
1.7
15
1.7
5.1
5
5.1
5
5.1
5
5.1
5
Output 2
U
o nom
I
o nom
[V DC] [A]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12
2
12
2
15
1.7
15
1.7
12
0.7
12
0.7
15
0.6
15
0.6
Output 3
U
o nom
I
o nom
[V DC] [A]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12
0.7
12
0.7
15
0.6
15
0.6
Input
voltage
U
i
[V AC]
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
85...264
Type
Options
LM 1001-7R
LMZ 1001-7R
LM 1301-7R
LMZ 1301-7R
LM 1501-7R
LMZ 1501-7R
LM 1601-7R
LMZ 1601-7R
LM 1901-7R
LMZ 1901-7R
LM 2320-7
LMZ 2320-7
LM 2540-7
LMZ 2540-7
LM 3020-7
LMZ 3020-7
LM 3040-7
LMZ 3040-7
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
www.power-one.com
1
How to implement boot animation
As the title says: Because WinCE takes too long to start up, I want to change the startup logo to an animation so that users don't feel that it takes too long. Is there any good way to implement the s...
zhaihw520 Embedded System
How to use a network cable to connect the development board and the computer?
How do I use a network cable to connect the development board to the computer? Do I need to set anything? Can any expert help me? Thank you very much...
冰冰忍者 Embedded System
Design of MSP430 reversing radar
[font=宋体][size=4][color=#000000]With the increasing demand for intelligent vehicle assisted driving systems and the development of automotive electronic systems, new reversing radars should be able to...
fish001 Microcontroller MCU
Has anyone used PIML's GPRS module? This question is too weird.
I found a very frustrating problem. When sending data using TCP, if there is 0x0D 0x0A in the data, the module will do some processing for you, and after receiving it, it will become 0x0D, 0x0D, 0x0A....
方案公司 Embedded System
How do I convert the differential signal from the fiber optic transceiver into a video signal (CVBS)?
How can I convert the differential signal from the fiber optic transceiver into a video signal (CVBS)? Does anyone have a recommended solution? Thanks!...
elec32156 Analog electronics
Crosstar Embedded Academy "Using /proc to implement kernel-user space communication"
The communication between Linux kernel space and user space can be realized by reading and writing files in the "/proc" directory. If you only control the parameters in the kernel instead of transmitt...
oyxian Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2634  540  2276  2889  2629  54  11  46  59  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号