5145.A326F150U2.831

Description
Mains Power Connector, 15A, 125/250VAC, Male, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size967KB,5 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance  
Download Datasheet Parametric View All

5145.A326F150U2.831 Overview

Mains Power Connector, 15A, 125/250VAC, Male, ROHS COMPLIANT

5145.A326F150U2.831 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerSCHURTER
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC/EN 60320-1; UL 94V-0; CSA; VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings15A, 125/250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Total number of contacts3
Base Number Matches1
Power entry modules with line filter
www.schurter.com/pg06
Inlet filter, front side mounting, circuit breaker TA45 2-pole
 
545
Standard- or Medical-Filter
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6145
- We recommend for new applications type DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
References
Weblinks
General Product Information
Approvals: www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
CHINA-RoHS: www.schurter.com/china-rohs
Webstore: www.schurterinc.com/estore/search.ihtml
Approvals
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; Hz 50
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
condition) pin-temperature 70 °C, 10 A,
Protection class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
Connectors

Ask for advice on small current amplification
I want to amplify a tiny signal of about 1~100nA. How many stages of op amps should I use? Which is better for the first stage, instrumentation amplifier or differential amplifier? Please give me some...
Linasity Analog electronics
How to use RAPI?
The current problem is that I have installed VS2005 and Smartphone SDK of WM5.0, and connected to the simulator that comes with VS2005 using Activesync. The question is, can I use CeXXX and other func...
ivy198632 Embedded System
LPC1768 realizes USB to CAN card function
LPC1768 realizes the function of USB to CAN card. Dear seniors, please tell me, my 1768 now has two CANs, but after plugging it in, it can only recognize one CAN. The driver is fine. I have used the U...
walkersfaint NXP MCU
Microphone noise problem
[backcolor=rgb(222, 240, 251)]In a small closed environment, the microphone audio is fuzzy after passing through the op amp; in an open environment, the sound picked up by the microphone is normal and...
timberabc Analog electronics
Please tell me where is the problem with my code?
I used the winter vacation to learn Keil C51. When I learned about dynamic scanning, there was a question: Use the three digital tubes on the experimental board to display from 000 to 999, increase ev...
lalaone 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1931  362  674  626  1271  39  8  14  13  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号