EEWORLDEEWORLDEEWORLD

Part Number

Search

C9509RA

Description
Rotary Coded Switch, 5 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size111KB,2 Pages
ManufacturerArcolectric
Environmental Compliance  
Download Datasheet Parametric View All

C9509RA Overview

Rotary Coded Switch, 5 Positions, Decimal, Latched, 20A, 28VDC, Quick Connect Terminal, Spindle Actuator, Panel Mount, ROHS COMPLIANT

C9509RA Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerArcolectric
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeSPINDLE
body width18.5 mm
body height32 mm
Body length or diameter32.3 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)20 A
Contact (DC) maximum rated R load20A@28VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)28 V
Manufacturer's serial number9100
Installation featuresPANEL MOUNT
Number of positions5
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDECIMAL
Switch typeROTARY CODED SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
9100 Rotary Switches
16A 250Vac
2 to 6 way rotary switch
Ratings up to 16A,
250V ac; 20A, 28V dc
Pairs of single pole
change over contacts
In house test
16(4)A 250Vac T125
16A 400Vac T125
8(8)A 250Vac T125 5E4 (50,000 Operations)
UL CSA 20A Non Ind 277Vac, 250Vac 2hp, 125Vac 1hp
UL85°C, file no. E45221, CSA file no. LR10990
30A 12V dc
RoHS compliant
9100 switches are highly versatile with up to 6 positions at 30° intervals and
6 terminals per switch. For more complex switching (7 positions & over),
contact the factory. Two switches may be stacked to give up to 12 terminal
switching.
3mm contact gap.
Technical data on pages 4 & 5.
Wide choice of
switching circuits
Can be stacked together
RoHS
C 9 5 01 D A Stop at 120˚
ORDER FORMAT
TERMINAL
C
2
9.2
TERMINAL SERIES POSITIONS CIRCUIT SPINDLE BODY OPTIONS
CODE
CODE
CODE
CODE
CODE CODE
SERIES
POSITION
CIRCUIT
9100 switches offer almost infinite
switching options
For this reason it is impractical to show all the
options available.
SPINDLE
A
ø6.0
4.5
A/F
26.0
Switching
positions
B
The table below gives an example of a
5 position switching sequence:
6.3 x 0.8
ø6.0
4.5
A/F
22.0
OFF, 1, 1+2, 1+2+3, 1+2+3+4
C
3
Switching
positions
1
A
2
3
B
Off
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5
ø6.0
4.5
A/F
10.8
D
ø6.05
4.65
A/F 12.2
M
ø6.0
15˚
4
5 A.65
/F
4
9
H
Switching
positions
4
12.2
The code
for your chosen circuit will be
allocated by our technicians.
Please contact the factory for details.
N
ø6.0
4.5
A/F
20.0
9.2
Use the blank table to plan your switching
up to 6 positions.
P
4.5
A/F
ø6.0
23.0
5
4.8 x 0.8
For approval information on H terminals,
contact the factory.
1
A
2
Switching
positions
Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6
R
4.5
ø6.0
A/F 12.2 20.1
for 2 gang switching
S
5
4. /F
A
˚
45
ø6.0
10.8
6
Simple circuits may not use all terminals.
Unnecessary terminals may be omitted.
Switching
positions
3
B
4
L
supplied without spindle
64
ARCOLECTRIC CORPORATION
31-315 Plantation Drive, Thousand Palms, CA 92276 Tel: 760-343-3650 Fax: 760-343-3651 email: info@arcolectric.com
The GPS schematic diagram is out, please give your opinions
Question update: 1. It is best to add 4.7K pull-up resistors to the SDA and SCL pins of 24C02. I didn't see any resistors on the schematic diagram of the 51 experimental board. I'm looking for informa...
tonytong DIY/Open Source Hardware
Weekly plan + solar following system
It’s time to get started! I hope it can pass the review, thank you!...
victorlee1988 Energy Infrastructure?
Application of 4G solar energy monitoring
[align=left][font=宋体]With the development of [/font]4G[font=宋体]industrial modules, more and more devices use [/font][font=宋体]4G[/font][font=宋体]industrial modules to achieve remote control. [/font][/al...
南方安创 Energy Infrastructure?
When debugging ads1247 with spi simulation, the register value cannot be read
I recently tuned TI's ads1247 and used the analog SPI method. I checked the SPI signal level on an oscilloscope, but I couldn't read the register value. That's strange....
songzh1436 Microcontroller MCU
I heard there are gifts for watching videos?
Wow, it’s true! You just need to follow my process once, and there will really be gifts!Event time: From now until September 10 , 2020 Activity process:Click here to enter the event page, and find any...
EEWORLD社区 Integrated technical exchanges
GD32E231 analog IIC driver LPS22HH
Last week I tried the STTS7551 temperature sensor (portal: GD32E231 simulates IIC to drive STTS751 ), and then I started trying the LPS22HH sensor. From the schematic diagram, they are all connected t...
hehung MEMS sensors

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1567  2317  304  1658  53  32  47  7  34  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号