EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-J0X-MX

Description
1-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE
CategoryPower/power management    The power supply circuit   
File Size177KB,5 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-J0X-MX Overview

1-OUTPUT 50 W DC-DC REG PWR SUPPLY MODULE

VI-J0X-MX Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerVICOR
package instruction,
Reach Compliance Codenot_compliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage20 V
Minimum input voltage10 V
Nominal input voltage12 V
JESD-30 codeR-XDMA-P9
JESD-609 codee0
Maximum load regulation0.2%
Number of functions1
Output times1
Number of terminals9
Maximum operating temperature100 °C
Minimum operating temperature-55 °C
Maximum output voltage5.72 V
Minimum output voltage2.6 V
Nominal output voltage5.2 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD OVER COPPER
Terminal formPIN/PEG
Terminal locationDUAL
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output75 W
Fine-tuning/adjustable outputYES
Data Sheet
VI-J00, VE-J00
Features
RoHS compliant (VE versions)
Up to 50 Watts per cubic inch
cULus, cTÜVus
CE Marked
Up to 90% efficiency
Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
Remote sense and current limit
Logic disable
Wide range output adjust
ZCS power architecture
Low noise FM control
Isolated output
Half Brick
DC-DC Converters
25 to 100 Watts
Product Highlights
The VI-J00 MiniMod family established a new standard in component-level DC-DC converters.
This “junior” size complement to the higher power VI-200 family offers up to 100 W of isolated
and regulated power in a board mounted package. With thousands of input/output/power
combinations, and with a maximum operating temperature rating of 100˚C, the MiniMod
provides nearly unlimited flexibiliy for power system designers to meet demanding time to
market requirements.
Utilizing Vicor’s “zero-current-switching” forward converter technology, proven by an installed
base of over 8 million units, the MiniMod family combines state of the art power density with
the efficiency, low noise and reliability required by next generation power systems.
Part Numbering
VI
J
6
1
C
W
Family
VI
= Non-RoHS
VE
= RoHS
Series
J
= J00
V
= 24 V
1
= 24 V
W
= 24 V
2
= 36 V
3
= 48 V
Input
0
= 12 V
N
= 48 V
4
= 72 V
T
= 110 V
5
= 150 V
6
= 300 V
7
= 150/300 V
Z
= 2V
Y
= 3.3 V
0
= 5V
X
= 5.2 V
W
= 5.5 V
V
= 5.8 V
T
= 6.5 V
R
= 7.5 V
Output
M
= 10 V
1
= 12 V
P
= 13.8 V
2
= 15 V
N
= 18.5 V
3
= 24 V
L
= 28 V
J
= 36 V
K
= 40 V
4
= 48 V
H
= 52 V
F
= 72 V
D
= 85 V
B
= 95 V
Grade
E
= –10 to 100°C
C
= –25 to 100°C
I
= – 40 to 100°C
M
= –55 to 100°C
5V
Power
<5
W
= 20 A
X
= 15 A
Y
= 10 A
Z
=5A
W
= 100 W
X
= 75 W
Y
= 50 W
Z
= 25 W
Note: For
additional
packaging options,
please see page 4.
Maximum Power Available for VI-Jxx-xx
Input
Voltage
Nom. (Range)
12 (10-20)
24 (10-36)
24 (21-32)
24 (18-36)
36 (21-56)
48 (42-60)
48 (36-76)
72 (55-100)
110 (66-160)
150 (100-200)
150 (100-375)
300 (200-400)
[a]
Output
Vin
Transient
[a]
Designators
2
Z
22
n/a
36
n/a
60
72
n/a
110
n/a
215
n/a
425
0
V
1
W
2
3
N
4
T
5
7
6
X
--
W
W
Y
W
W
W
W
W
Y
W
3.3
Y
X
Y
W
W
Y
W
W
W
W
W
Y
W
5
0
Y
Y
W
W
Y
W
X
W
X
W
Y
W
5.2 5.5 5.8 6.5 7.5 10
X W V T
R M
Y
Y
W
W
Y
W
X
W
X
W
Y
W
Y
Y
W
W
Y
W
X
W
X
W
Y
W
Y
Y
W
W
Y
W
X
W
X
W
Y
W
Y
Y
X
X
Y
X
X
X
X
X
Y
X
Y
Y
X
X
Y
X
X
X
X
X
Y
X
X
Y
W
W
X
W
W
W
W
W
X
W
Vout Designators
12 13.8 15 18.5 24 28
1
P
2 N
3 L
X
Y
W
W
X
W
W
W
W
W
X
W
X
Y
W
W
X
W
W
W
W
W
X
W
X
Y
W
W
X
W
W
W
W
W
X
W
X
Y
W
W
X
W
W
W
W
W
X
W
X
Y
W
W
X
W
W
W
W
W
X
W
X
Y
W
W
X
W
W
W
W
W
X
W
36 40
J K
X
Y
W
W
X
W
W
W
W
W
X
W
X
Y
W
W
X
W
W
W
W
W
X
W
48
4
X
Y
W
W
X
W
W
W
W
W
X
W
52
H
X
--
W
W
X
W
W
W
W
W
X
W
72 85
F D
X
--
W
W
--
W
W
W
W
W
--
W
X
--
W
W
--
W
W
W
--
W
--
W
95
B
X
--
W
W
--
W
W
W
--
W
--
W
Low Line
75%
Max Power
n/a
n/a
18
n/a
18
36
n/a
45
n/a
85
90
170
Transient voltage for 1 second.
Vicor Corp.
Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
VI-J00 MiniMod DC-DC Converters 25 to 100 Watts
Rev. 2.3
Page 1 of 5
Set your site on VICOR at vicorpower.com
Where can I download English papers?
Embedded technology, preferably about bootloader, about 5,000 words, thank you....
tigeracl Embedded System
Does anyone have the source code for impedance tracking of TI MSP430?
Does anyone have the source code for impedance tracking of TI MSP430?...
Study_Stellaris Analogue and Mixed Signal
Please help me find the program of this module. I can't compile it. I'm sorry.
Please help me find the program of this module. I can't compile it....
ylf175300 51mcu
A few pictures help you easily understand DDR crosstalk
Original article by Mr. High Speed | Huang GangIf you are asked to evaluate the crosstalk of high-speed serial signals, you will say that their crosstalk is below -40db and has no effect. But if you a...
yvonneGan PCB Design
Some notes on MSP430 VLO
VLO is an ultra-low power low-frequency oscillator inside the MSP430. This clock source is not available in the 1xx series of the MSP430, but has already appeared in the 2 series. Currently, the G2 se...
wstt Microcontroller MCU
How to change the minimum time recognition in the protocol stack
I need to recognize the time as 0.5ms, that is, the maximum time increment should be 0.5ms, but now it can only recognize the integer multiple of 1ms. How can I change it?...
空空小道人 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 786  1266  1925  405  255  16  26  39  9  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号