The Agilent 8560 EC Series spectrum analyzers have a color display,
offer standard digitized fast time domain sweeps (Option 856xE-007
on the 8560 E Series), and are Class 3 MIL-rugged. The 8560 EC
Series is identical to the 8560E Series in all other respects.
Frequency Specifications, Agilent 8560 EC Series
Unless noted, all specifications describe the instrument’s warranted performance under the following conditions: 5-minute warm-up from ambient conditions,
autocoupled controls, digital display, IF ADJ ON, REF LVL CAL adjusted, SECOND IF OUTPUT and 1ST LO OUTPUT terminated in 50 Ω. After a 30-minute warm-up,
and over a temperature range of 20 °C to 30 °C, the preselector does not have to be peaked at each signal of interest; under these conditions factory preselector
peak values are sufficient to meet all specifications. Typical performance is non-warranted. Supplemental characteristics are denoted by “nominal” and
“approximately”; these constitute non-warranted functional performance information derived during the design process and are not tested on a continuing basis.
Frequency range
Internal
mixing
External
mixing
8560EC
30 Hz
2
to
2.9 GHz
18 GHz to
325 GHz
8561EC
30 Hz
2
to
6.5 GHz
18 GHz to
325 GHz
8562EC
30 Hz
2
to
13.2 GHz
18 GHz to
325 GHz
8563EC
30 Hz
1
to
26.5 GHz
18 GHz to
325 GHz
8564EC
30 Hz
1
to
40 GHz
18 GHz to
325 GHz
8565EC
30 Hz
1
to
50 GHz
18 GHz to
325 GHz
Frequency band
30 Hz to 2.9 GHz
2.75 GHz to 6.46 GHz
5.86 GHz to 13.2 GHz
12.4 GHz to 26.8 GHz
26.4 GHz to 31.15 GHz
31.0 GHz to 50 GHz
Harmonic mixing mode (N)
1
1
2
4
4
8
Option 856xEC-103
±1x10
–6
±2x10
–6
±1 x 10
–6
Frequency reference
Temperature stability 3
Aging
(per year)
(per day nom.)
Initial achievable accuracy
Short-term warmup accuracy factors (nominal)
5 minute
15 minute
±1 x
±1 x 10
–7
±5 x 10
–10 (4)
±2.2 x 10
–8
±1 x 10
–7
±1 x 10
–8
10
–8
Frequency readout accuracy
(Start, stop, center and marker frequency functions)
Span > 2 MHz x N
5
±(freq readout x freq ref accuracy 6 +5% x span +15% x RBW +10 Hz)
Span ≤ 2 MHz x N
5
±(freq readout x freq ref accuracy 6 +1% x span +15% x RBW +10 Hz)
1. How to create your own component library? [/size][/font][/backcolor][/color] [color=rgb(153, 51, 0)][backcolor=rgb(245, 250, 255)][font=Tahoma, Helvetica, Arial, sans-serif][size=14px] After creati...
With the market demand for increasingly portable and miniaturized medical imaging systems, Texas Instruments (TI) has launched a complete analog signal chain solution designed for portable ultrasound ...
My CCS is version 5.4. Today, I clicked the update button and it stopped opening. The following image appears: [img]data:image/png;base64,iVBORw0KGgoAAAANSUhEUgAAAjEAAAH9CAIAAABkz7rxAAAgAElEQVR4nO29eZ...
Switching power supplies are widely used in communication, control, computer and other fields due to their small size and high power factor. However, due to the electromagnetic interference, their fur...