DISCRETE SEMICONDUCTORS
DATA SHEET
BGY82
CATV amplifier module
Product specification
Supersedes data of 1997 Apr 15
File under Discrete Semiconductors, SC16
1998 Mar 02
Philips Semiconductors
Product specification
CATV amplifier module
FEATURES
•
Excellent linearity
•
Extremely low noise
•
Silicon nitride passivation
•
Rugged construction
•
Optimal reliability ensured by TiPtAu metallized crystals.
APPLICATIONS
•
CATV systems operating in the 40 to 450 MHz
frequency range.
DESCRIPTION
Hybrid amplifier module in a SOT115J package operating
with a voltage supply of 24 V (DC).
PINNING - SOT115J
PIN
1
2
3
5
7
8
9
input
common
common
+V
B
common
common
output
BGY82
DESCRIPTION
handbook, halfpage
1
2
3
5
7
8
9
Side view
MSA319
Fig.1 Simplified outline.
QUICK REFERENCE DATA
SYMBOL
G
p
I
tot
power gain
total current consumption (DC)
PARAMETER
CONDITIONS
f = 50 MHz
f = 450 MHz
V
B
= 24 V
MIN.
13.5
14.5
−
−
−
180
MIN.
MAX.
14.5
−
200
UNIT
dB
dB
mA
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
SYMBOL
V
i
T
stg
T
mb
RF input voltage
storage temperature
operating mounting base temperature
PARAMETER
−
−40
−20
MIN.
65
+100
+100
MAX.
°C
°C
UNIT
dBmV
1998 Mar 02
2
Philips Semiconductors
Product specification
CATV amplifier module
CHARACTERISTICS
Bandwidth 40 to 450 MHz; T
mb
= 30
°C;
Z
S
= Z
L
= 75
Ω.
SYMBOL
G
p
SL
FL
S
11
PARAMETER
power gain
slope cable equivalent
input return losses
CONDITIONS
f = 50 MHz
f = 450 MHz
f = 40 to 450 MHz
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 450 MHz
S
22
output return losses
f = 40 to 80 MHz
f = 80 to 160 MHz
f = 160 to 450 MHz
CTB
X
mod
CSO
d
2
V
o
F
I
tot
Notes
1. f
p
= 55.25 MHz; V
p
= 46 dBmV;
f
q
= 391.25 MHz; V
q
= 46 dBmV;
measured at f
p
+ f
q
= 446.5 MHz.
2. Measured according to DIN45004B:
f
p
= 440.25 MHz; V
p
= V
o
;
f
q
= 447.25 MHz; V
q
= V
o
−6
dB;
f
r
= 449.25 MHz; V
r
= V
o
−6
dB;
measured at f
p
+ f
q
−
f
r
= 438.25 MHz.
3. The module normally operates at V
B
= 24 V, but is able to withstand supply transients up to 30 V.
composite triple beat
cross modulation
composite second order
distortion
second order distortion
output voltage
noise figure
60 channels flat; V
o
= 46 dBmV;
measured at 445.25 MHz
60 channels flat; V
o
= 46 dBmV;
measured at 55.25 MHz
60 channels flat; V
o
= 46 dBmV;
measured at 446.25 MHz
note 1
d
im
=
−60
dB; note 2
f = 450 MHz
flatness of frequency response f = 40 to 450 MHz
MIN.
13.5
14.5
0.2
−
20
19
18
20
19
18
−
−
−
−
61.5
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
−
180
TYP.
BGY82
MAX.
14.5
−
1.5
±0.2
−
−
−
−
−
−
−55
−56
−55
−72
−
7
200
UNIT
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dBmV
dB
mA
total current consumption (DC) note 3
1998 Mar 02
3
Philips Semiconductors
Product specification
CATV amplifier module
PACKAGE OUTLINE
Rectangular single-ended package; aluminium flange; 2 vertical mounting holes;
2 x 6-32 UNC and 2 extra horizontal mounting holes; 7 gold-plated in-line leads
BGY82
SOT115J
D
E
Z
P
A2
1
A
L
F
S
W
d
U2
B
Q
e
e1
q2
q1
y
M
B
y
M
B
b
w
M
2
3
5
7
8
9
c
P
U1
q
0
5
scale
10 mm
DIMENSIONS (mm are the original dimensions)
UNIT
A2
A
max. max.
9.1
b
c
d
D
E
max. max. max.
e
e1
F
L
Q
∅
P
min.
max.
8.8
4.15
3.85
2.4
q
q1
q2
S
U1
U2
max.
8
W
w
y
0.1
Z
max.
3.8
mm 20.8
0.51
0.25 27.2 2.54 13.75 2.54 5.08 12.7
0.38
38.1 25.4 10.2
4.2 44.75
6-32 0.25
UNC
OUTLINE
VERSION
SOT115J
REFERENCES
IEC
JEDEC
EIAJ
EUROPEAN
PROJECTION
ISSUE DATE
97-04-10
1998 Mar 02
4
Philips Semiconductors
Product specification
CATV amplifier module
DEFINITIONS
Data Sheet Status
Objective specification
Preliminary specification
Product specification
Limiting values
BGY82
This data sheet contains target or goal specifications for product development.
This data sheet contains preliminary data; supplementary data may be published later.
This data sheet contains final product specifications.
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or
more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation
of the device at these or at any other conditions above those given in the Characteristics sections of the specification
is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
LIFE SUPPORT APPLICATIONS
These products are not designed for use in life support appliances, devices, or systems where malfunction of these
products can reasonably be expected to result in personal injury. Philips customers using or selling these products for
use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such
improper use or sale.
1998 Mar 02
5