NOTE: Printed circuit board mount: 57mm x 57mm minimum area x
1.6mm thick G10 epoxy glass, or equivalent.
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
1.
θ
JA
is measured with the component mounted on an evaluation PC board in free air.
Static Electrical Specifications
at T
A
= -40
o
C to +85
o
C, Unless Otherwise Noted
CONDITIONS
CDP1854A
LIMITS
CDP1854AC
(NOTE 1)
TYP
0.02
-
2
-
PARAMETER
Quiescent Device
Current
I
DD
V
O
(V)
-
-
V
IN
(V)
0, 5
0, 10
0, 5
0, 10
V
DD
(V)
5
10
5
10
MIN
-
-
1
2
(NOTE 1)
TYP
0.01
1
2
4
MAX
50
200
-
-
MIN
-
-
1
-
MAX
200
-
-
-
UNITS
µA
µA
mA
mA
Output Low Drive
(Sink) Current
(Except pins 24 and
25)
Output High Drive
(Source) Current
I
OL
0.4
0.5
I
OH
4.6
9.5
0, 5
0, 10
0, 5
0, 10
0, 5
0, 10
0, 5
0, 10
-
-
-
-
0, 5
0, 10
5
10
5
10
5
10
5
10
5
10
5
10
5
10
-0.55
-1.3
1.6
3.2
-
-
4.9
9.9
-
-
3.5
7
-
-
-1.1
-2.6
3.5
7
0
0
5
10
-
-
-
-
-
-
-
-
-
-
0.1
0.1
-
-
1.5
3
-
-
±1
±2
-0.55
-
1.6
-
-
-
4.9
-
-
-
3.5
-
-
-
-1.1
-
3.5
-
0
-
5
-
-
-
-
-
-
-
-
-
-
-
0.1
-
-
-
1.5
-
-
-
±1
-
mA
mA
mA
mA
V
V
V
V
V
V
V
V
µA
µA
Output Low Drive
(Sink) Current
(Pins 24 and 25)
Output Voltage
Low-Level (Note 2)
I
OL
0.4
0.5
V
OL
-
-
Output Voltage
High-Level (Note 2)
V
OH
-
-
Input Low Voltage
V
IL
0.5, 4.5
0.5, 9.5
Input High Voltage
V
IH
0.5, 4.5
0.5, 9.5
Input Current
I
IN
-
-
4
CDP1854A, CDP1854AC
Static Electrical Specifications
at T
A
= -40
o
C to +85
o
C, Unless Otherwise Noted
(Continued)
CONDITIONS
CDP1854A
V
O
(V)
I
OUT
0, 5
0, 10
Operating Current
(Note 3)
I
DD1
-
-
Input Capacitance
Output Capacitance
NOTES:
1. Typical values are for T
A
= 25
o
C.
2. I
OL
= I
OH
= 1µA.
3. Operating current is measured at 200kHz or V
DD
= 5V and 400kHz for V
DD
= 10V in a CDP1800-series microprocessor system, with
open outputs.
C
IN
C
OUT
-
-
V
IN
(V)
0, 5
0, 10
0, 5
0, 10
-
-
V
DD
(V)
5
10
5
10
-
-
(NOTE 1)
TYP
-
-
1.5
6
5
10
LIMITS
CDP1854AC
(NOTE 1)
TYP
-
-
1.5
-
5
10
PARAMETER
Three-State Output
Leakage Current
MIN
-
-
-
-
-
-
MAX
±1
±10
-
-
7.5
15
MIN
-
-
-
-
-
-
MAX
±1
-
-
-
7.5
15
UNITS
µA
µA
mA
mA
pF
pF
Operating Conditions
At T
A
= Full Package-Temperature Range. For maximum reliability, operating conditions should be selected
so that operation is always within the following ranges: