Description
Reset Sequence Pushbutton
CategoryPower/power management    The power supply circuit   
File Size274KB,7 Pages
ManufacturerDALLAS
Websitehttp://www.dalsemi.com
Download Datasheet Parametric Compare View All

DS1830S Online Shopping

Suppliers Part Number Price MOQ In stock  
DS1830S - - View Buy Now

DS1830S Overview

Reset Sequence Pushbutton

DS1830S Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
Is SamacsysN
Other featuresPUSHBUTTON RESET INPUT
Adjustable thresholdYES
Analog Integrated Circuits - Other TypesPOWER SUPPLY SUPPORT CIRCUIT
JESD-30 codeR-PDSO-G8
Number of channels1
Number of functions1
Number of terminals8
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Package body materialPLASTIC/EPOXY
encapsulated codeSOP
Package shapeRECTANGULAR
Package formSMALL OUTLINE
Certification statusNot Qualified
surface mountYES
Temperature levelINDUSTRIAL
Terminal formGULL WING
Terminal locationDUAL
Base Number Matches1
DS1830/A DS183
DS1830/A
Reset Sequence Pushbutton
www.maxim-ic.com
FEATURES
§
§
§
§
§
§
§
§
§
§
5V (DS1830) or 3.3V (DS1830A) power-on
reset
Excellent for systems that need power-on
resets in a consistent sequence
Asserts resets during power transients
Pushbutton reset input for system override
Selectable reset timing
Reduces need for discrete components
Precision temperature-compensated voltage
reference
8-pin DIP, 8-pin SO, or space saving 8-pin
µSOP
Operating temperature of -40°C to +85°C
Open-drain, active-low inputs
PIN ASSIGNMENT
PIN DESCRIPTION
1
PBRST
2 TD
3 TOL
4 GND
8 V
CC
7
RST1
6
RST2
5
RST3
- Pushbutton Reset Input
- Time Delay Select Input
- V
CC
Tolerance Select Input
- Ground
- Power Supply
- Reset 1 Output
- Reset 2 Output
- Reset 3 Output
DESCRIPTION
The DS1830 Reset Sequencer monitors the power supply for an in-tolerance condition and the pushbutton
reset input for a manual reset. First a precision temperature-compensated reference and comparator circuit
monitors the status of the power supply and when an out-of-tolerance condition is detected, an internal
power fail signal is generated that forces the reset lines to go to an active state. If the power supply
returns to an in-tolerance condition,
RST1
will release followed by
RST2
and finally
RST3
. Sequencing of
resets allows for systems to power-up in an orderly manner providing superior reliability.
Note:
Some revisions of this device may incorporate deviations from published specifications known as errata. Multiple revisions of any
device may be simultaneously available through various sales channels. For information about device errata, click here:
http://dbserv.maxim-
ic.com/errata.cfm.
1 of 7
060303

DS1830S Related Products

DS1830S DS1830 DS1830A DS1830AS DS1830AU DS1830U
Description Reset Sequence Pushbutton Reset Sequence Pushbutton Reset Sequence Pushbutton Reset Sequence Pushbutton Reset Sequence Pushbutton Reset Sequence Pushbutton
Reach Compliance Code unknow unknow unknow unknow unknow unknow
Base Number Matches 1 1 - 1 1 -

Recommended Resources

Popular Articles

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 450  2320  937  2413  2123  10  47  19  49  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号