LK4501-9ERD0T

Description
AC-DC Power Factor Correction Module, 1 Output, 150W, Hybrid, HEAT SINK, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size606KB,28 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LK4501-9ERD0T Overview

AC-DC Power Factor Correction Module, 1 Output, 150W, Hybrid, HEAT SINK, METAL, CASE K02, MODULE

LK4501-9ERD0T Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage85 V
Nominal input voltage230 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage16.5 V
Minimum output voltage
Nominal output voltage15 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputYES
Base Number Matches1
Cassette Style
150 Watt AC-DC Converters
K Series PFC
150 Watt AC-DC Converters with PFC
Input voltage range from 85...255 V AC
1or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
K-Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K 4000/5000-series of AC-DC converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified ranges. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected with pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19 inch rack sys-
tems according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the
LK 1000 and LK 2000 in order to comply with IEC/EN
61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 16
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 28
1/28
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 12
Edition 01/01.2001
Mitsubishi PLC full range of Chinese simulation software
It can be downloaded from http://download.gongkong.com/file/2006/12/14/simulator.rar , a total of 14.6M....
totopper Industrial Control Electronics
Why can't I open the photos taken by the camera? Please help me.
I encountered a problem today. The photos taken by the camera can be opened with the tools provided by Windows, and they are very clear. However, when opened with ACDSEE and PHOTOSHOP, they are all bl...
mingjin27 Embedded System
Simple MCU and multi-axis SPI communication TSSOP20 package motion control chip mpc02t communication program
[align=left][color=black][font=宋体][size=12.0pt]#include [/size][/font][/color][/align][align=left][color=black][font=宋体][size=12.0pt]//-----STC89C2051-------[/size][/font][/color][/align][align=left][...
w75815895 MCU
Using all his strength, he took apart a big, glittering golden thing. Guess what treasure this is?
It was my first time disassembling something like this. It took me more than an hour to open the shell. I was so tired that I took some time to sort it out after the Chinese New Year. I guess there ar...
littleshrimp RF/Wirelessly
Problems encountered in software simulation
When doing software simulation of Example_281xGpioLoopback.pjt, the gpio is set as a general-purpose input and output port, GPIO Test #1: Configure Upper 8 bits of Port A as outputs and lower 8 bits a...
qlb Microcontroller MCU
Are there any companies in China that develop operating systems or embedded operating systems?
I am interested in embedded operating system development, but my current company does not have such conditions. . . ....
faiou Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 381  1119  1610  373  1077  8  23  33  22  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号