EEWORLDEEWORLDEEWORLD

Part Number

Search

B84312-C100-H4

Description
Data Line Filter, 20 Function(s), 250V, 1A,
CategoryAnalog mixed-signal IC    filter   
File Size39KB,1 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance
Download Datasheet Parametric View All

B84312-C100-H4 Overview

Data Line Filter, 20 Function(s), 250V, 1A,

B84312-C100-H4 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTDK Corporation
Reach Compliance Codecompliant
ECCN codeEAR99
Maximum DC resistance0.6 Ω
filter typeDATA LINE FILTER
high160 mm
length370 mm
Manufacturer's serial numberB84312
Installation typePANEL MOUNT
Number of functions20
physical sizeL370XB84XH160 (mm)
Rated current1 A
Rated voltage250 V
Base Number Matches1
Filter für geschirmte Räume
Filters for Shielded Rooms
Für Kommunikationsleitungen
analog
s
Filter für analoge Systeme und
Steuerleitungen
s
Sperrdämpfung bis 40 GHz
Bemessungs-
spannung U
R
:
Klimakategorie:
80 V – /42 V~
250 V – /100 V~
25/085/56
For communication lines
analog
s
Filters for analog systems and
control lines
s
Stop band attenuation
up to 40 GHz
Rated voltage V
R
: 80 V – /42 V~
250 V – /100 V~
Climatic category: 25/085/56
Durchlass-
band
Pass band
kHz
0…3,4
0…3,4
Leitungs-
Anwendung
impedanz Application
Line
impedance
600
600
Standard-Telefonsysteme
Standard telephone systems
Telefonsysteme für erhöhte
Anforderungen (Sperrdämpfung
von 100 dB ab 10 kHz
Telephone systems for enhanced
requirements (stop band attenua-
tion of 100 dB above 10 kHz)
Telefonsysteme und Modem-
leitungen sowie bedingt geeignet
für Steuerleitungen mit kritischer
Flankensteilheit
Telephone systems and modem
cables, conditionally for control
lines with critical signal rise times
Datensignale mit symmetrischer
Übertragungsart wie bei Modems
oder Übertragungsschnittstelle
RS 485 bis 9600 Baud bzw.
RS 422 bis 19200 Baud
Data signals with balanced signal
transmission mode as used by
modems or interfaces
RS 485 up to 9600 Baud /
RS 422 up to 19200 Baud
Universalfilter für Steuer-
und Schaltleitungen bis 1 A
Universal filters for signal
and control lines with up to 1 A
Steuerleitungen bis 1 A
bei erhöhten Dämpfungs-
anforderungen
Control lines with up to 1 A
and enhanced attenuation
requirements
I
R
R
max
je Leitung
per line
11
17
Leiter
Lines
Bestellnummer
1)
Ordering code
1)
A
0,1
0,1
2
20
2
20
B84312 - *20-B3
B84312-C20-H3
B84312 - *90-B4
B84312-C90-H4
0…50
600
0,1
1,1
2
20
B84312 - *40-B1
B84312-C40-H1
0…120
0…300
150
150
0,1
0,1
4,4
1,6
2
20
2
B84312 - *50-B1
B84312-C50-H1
B84312 - *60-B1
1
0,4
2
20
2
20
B84312 - *30-B3
B84312-C30-H3
B84312- *100-B4
B84312-C100-H4
1
0,6
Gehäusemaße ohne Anschlüsse (mm) / Case dimensions without fittings (mm)
Leitungen / Lines
2
20
Länge / Length (mm)
262
370
Breite / Width (mm)
25
84
Höhe / Height (mm)
56
160
1) *: „C“: stehende Montageart; „F“: flache Montageart
*: “C”: upright mounting mode; “F”: flat mounting mode
EPCOS AG
49
The power consumption of PIC16F1933 is more than 30 microamperes. I need to reduce it to the minimum. Please help!
The system is powered by 3V. Because it is battery powered, the power consumption is very strict. The general working process is as follows: detect the sensor signal every 2 seconds, respond if action...
myjack Microchip MCU
Debugging problem, I don't know how to change the C debugger
Ask for help...
snowflyxyz stm32/stm8
Where can I download the S1P and S2P files of SAW devices?
After reading this article: [url]http://www.spectrum-soft.com/news/winter2012/nport.shtm[/url], I decided to simulate a SAW oscillator, but unfortunately there is no S1P file. Some people may say that...
huayuliang RF/Wirelessly
Why can't the butterfly valve be opened and closed by direct ventilation of the cylinder?
Do you know what transistors, relays, and contactors are used for? If the output power of the transistor is large enough, there is no need to add a relay or a contactor behind the transistor, and the ...
eeleader Industrial Control Electronics
Build F7 GCC development environment + RadioYúN
[size=3][font=微软雅黑]This topic is not very related to the project, but it's time to share, so I have to post something, otherwise it's not good to drink nmg. After a few days of discussion, IAR7405 ver...
lyzhangxiang stm32/stm8
What are the high frequency crossovers?
I would like to ask you a question, what are the high-frequency crossovers?...
chenmo Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 813  1875  854  1452  913  17  38  18  30  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号