3-Line Filters
for Converters and Power Electronics
Power line filters for three-phase systems
Rated voltage 520/300 V~, 50/60 Hz
Rated current 8 bis 150 A
Construction
■
Three-line filter
■
Metal case
B84143A*R105
Features
■
■
■
■
■
Excellent price/performance ratio
Ultra-compact design, low weight
Low leakage current
Easy to install
Construction complies with
EN 133200, UL 1283, CSA 22.2 No. 8 1986
■
Optimized for long motor cables and operation
under full loads
■
UL and CSA approval
Applications
■
Frequency converters for motor drives, e.g.
– elevators
– pumps
– traction systems
– HVAC systems (heating, ventilation and air conditioning)
■
Power supplies
Terminals
Safe-to-touch terminal blocks
Marking
Marking on component:
Manufacturer‘s logo, ordering code,
rated voltage, rated current,
rated temperature, climatic category, date code
Minimum marking on packaging:
Manufacturer‘s logo, ordering code
1
08/03
3-Line Filters
for Converters and Power Electronics
Typical circuit diagram
LINE
L1
L2
L3
LOAD
L1’
L2’
L3’
B84143A*R105
SSB1965-K
Technical data
Rated voltage V
R
Rated current I
R
Test voltage V
test
Overload capability
Leakage current I
leak
Climatic category
520/300 VAC, 50/60 Hz
Referred to 40
°C
ambient temperature
2236 VDC, 2 s (line/line)
2720 VDC, 2 s (line/case)
1.5 · I
R
for 3 min per hour or
2.5 · I
R
for 30 s per hour
at 520 VAC, 50 Hz
25/085/21 (–25
°C/+85 °C/21
days damp heat test)
in accordance with EN 60068-1
2
08/03
3-Line Filters
for Converters and Power Electronics
Characteristics and ordering codes
I
R
A
8
16
25
36
50
66
90
120
150
Terminal
I
leak
cross section typ
1)
mm
2
4
4
4
10
10
16
35
35
50
mA
13
15
15
15
15
16
18
18
18
R
typ
mΩ
16
9
5
4
2
1.5
1.1
0.90
0.55
Approx
weight
kg
0.58
0.90
1.10
1.75
1.75
2.7
4.2
4.9
5.3
B84143A0008R105
B84143A0016R105
B84143A0025R105
B84143A0036R105
B84143A0050R105
B84143A0066R105
B84143A0090R105
B84143A0120R105
B84143A0150R105
Ordering code
B84143A*R105
Approvals
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Tightening torques for PE studs and terminal blocks
I
R
A
8
16
25
36
50
66
90
120
150
Terminals
mm
2
4
4
4
10
10
16
35
35
50
Tightening torque
0.5 to 0.6 Nm
0.5 to 0.6 Nm
0.5 to 0.6 Nm
1.2 to 1.5 Nm
1.2 to 1.5 Nm
1.5 to 1.8 Nm
3.2 to 3.7 Nm
3.2 to 3.7 Nm
6 to 8 Nm
PE stud
Size
M4
×
11
M5
×
15
M5
×
15
M6
×
24
M6
×
24
M6
×
24
M10
×
34
M10
×
34
M10
×
34
Tightening torque
1.4
±0.1
Nm
2.8
±0.1
Nm
2.8
±0.1
Nm
4.8
±0.2Nm
4.8
±0.2
Nm
4.8
±0.2
Nm
23.3
±1
Nm
23.3
±1
Nm
23.3
±1
Nm
1)
At rated operation
3
08/03