C O A X I A L
C A B L E S
6.23
Broadband Coax
CATV Cables
Series 6
Standard
Nominal
Conductor
UL NEC/ Standard Lengths Unit Weight
Core OD
(stranding)
C(UL) CEC
Diameter
Type
Ft.
m
Lbs.
kg Nom. DCR Inch mm
Shielding Nominal OD
Materials
Nom. DCR Inch mm
Nominal
Nom. Nom. Capacitance
Vel.
Imp.
of
(Ω) Prop. pF/Ft. pF/m
Nominal
Attenuation
dB/
dB/
MHz 100 Ft. 100m
Description
Part
No.
Series 6 • 18 AWG
Solid .040″ Bare Copper-covered Steel • Duobond Plus
®
+ 80% Aluminum Braid Shield
Gas-injected Foam Polyethylene Insulation • Black PVC Jacket
80°C
9058
NEC:
CATV
CM
CEC:
CM
U-1000
x
U-304.8
304.8
1000
v
33.0 15.0
33.0 15.0
18 AWG .180
(solid)
.040″
BCCS
28.0Ω/M′
91.9Ω/km
4.57 Duobond Plus .275 6.99
75
83% 16.2 53.1
+ 80%
Aluminum
Braid
Sweep tested 5 MHz to 1 GHz.
4.6Ω/M′
15.1Ω/km
See Chart
on page 6.88
Shorting Fold
v
x
1000 ft. put-up also available in White.
U-1000 ft. put-up also available in White or Beige.
80°C
9072
u
NEC:
CATV
CM
CEC:
CM
1000
304.8
70.0 31.8
18 AWG .180
(solid)
.040″
BCCS
28.0Ω/M′
91.9Ω/km
4.57 Duobond Plus .280 7.11
75
83% 16.2 53.1
x
x
+ 80%
Aluminum .605 15.37
Braid
4.6Ω/M′
Sweep tested 5 MHz to 1 GHz.
15.1Ω/km
See Chart
on page 6.88
Shorting Fold
80°C
9059AM
1000
304.8
47.0 21.4
Shorting Fold
.051″ (1.3mm) galvanized steel messenger.
18 AWG .180
(solid)
.040″
BCCS
28.0Ω/M′
91.9Ω/km
4.57 Duobond Plus .275 6.99
75
83% 16.2 53.1
x
x
+ 80%
Aluminum .416 10.57
Braid
4.6Ω/M′
Sweep tested 5 MHz to 1 GHz.
15.1Ω/km
See Chart
on page 6.88
80°C
1260AM
1000
304.8
47.0 21.4
Shorting Fold
CoreGuard
®
18 AWG .180
(solid)
.040″
BCCS
28.0Ω/M′
91.9Ω/km
4.57 Duobond Plus .275 6.99
75
83% 16.2 53.1
x
x
+ 80%
Aluminum .416 10.57
Braid
4.6Ω/M′
Sweep tested 5 MHz to 1 GHz.
15.1Ω/km
See Chart
on page 6.88
.051″ (1.3mm) galvanized steel messenger.
Gas-injected Foam Polyethylene Insulation • Polyethylene Jacket
(Black or Orange)
Burial
80°C
9062
1000
304.8
29.0 13.2
18 AWG .180
(solid)
.040″
BCCS
28.0Ω/M′
91.9Ω/km
4.57 Duobond Plus .275 6.99
75
83% 16.2 53.1
+ 80%
Aluminum
Braid
Sweep tested 5 MHz to 1 GHz.
4.6Ω/M′
15.1Ω/km
See Chart
on page 6.88
Shorting Fold
CoreGuard
®
BC = Bare Copper • BCCS = Bare Copper-covered Steel • DCR = DC Resistance
Contact the Belden Customer Service Department for a Comprehensive Connector Cross Reference.
1-800-BELDEN-1.
B e l d e n E l e c t r o n i c s D i v i s i o n
Te c h n i c a l S u p p o r t :
1 - 8 0 0 - B E L D E N - 1
o r
1 - 8 0 0 - B E L D E N - 3
w w w . b e l d e n . c o m
6
Coaxial Cables

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2771  2912  1320  2453  2437  56  59  27  50  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号