EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-814-33-1500RLF

Description
Board Connector, 66 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-814-33-1500RLF Overview

Board Connector, 66 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle

54122-814-33-1500RLF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerAmphenol
Reach Compliance Codecompliant
body width0.19 inch
subject depth0.591 inch
body length3.3 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee3
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness15u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER KINKED LEADS
Total number of contacts66
Base Number Matches1
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
How to choose the correct charging method for electric vehicles
[i=s]This post was last edited by qwqwqw2088 on 2016-6-6 08:47[/i] Although more and more people choose to buy electric cars, it is still a new thing for most electric car owners, and they don’t know ...
qwqwqw2088 Energy Infrastructure?
How to read PANID and channel parameters in ZigBee application layer? Urgent! ! ! ! !
As the title says, how can I read the network's PANID and channel parameters at the application layer, which are the attributes in _NIB?...
weiruiqi120 RF/Wirelessly
MFC ActiveX control cannot respond to WM_DEVICECHANGE message
As the title says, I made a control some time ago, and it could respond to it yesterday, but... There is no WM_DEVICECHANGE in vc6.0 classwizard, so I added the code manually as follows: 1. Add afx_ms...
allanfy Embedded System
ucos information
:victory:...
huzx189 Microchip MCU
AD0832 driver, please help!
In the program, data is output from D0 starting from the falling edge of the fourth pulse, and the lowest bit of data is sent out at the eleventh pulse. The output of one byte of data is completed. So...
北北 MCU
Encoder output signal problem
There are two types of rotary encoder output: NPN and PNP. As an application user, I only know that the output signals are A, B, and Z. By connecting the three signals to the microcontroller and calcu...
shirle 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1515  437  509  1806  1417  31  9  11  37  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号