I500RU
4:1 Input, 5W
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Series
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
5W Output Power
•
4:1 Input Range
•
Miniature Case
•
Single & Dual Outputs
•
1,500 VDC Isolation
•
>1 MHour MTBF
•
16 Standard Models
•
LOWEST COST!!
Input
Parameter
Input Voltage Range
Input Filter
Reverse Polarity Input Current
Conditions
24 VDC Input
48 VDC Input
Min.
9.0
18.0
Typ.
24.0
48.0
Max.
36.0
72.0
1.0
Conditions
Positive
Negative
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 10% to 100%
±0.2
±0.5
30
75
120
±0.02
Continuous (Autorecovery)
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
100
300
Conditions
Ambient
Min.
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Typ.
+25
Max.
+85
+125
Typ.
Max.
Units
VDC
MΩ
pF
kHz
Units
ºC
ºC
±0.03
Min.
Typ.
±1.0
±3.0
Max.
±3.0
±5.0
±1.0
±0.5
±1.0
50
150
mV P - P
mV P - P
%
%/ºC
Units
VDC
LC Filter
A
Units
%
%
%
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple (20 MHz) (Note 1)
Noise (20 MHz) (Note 1)
Output Power Protection
Temperature Coefficient
Output Short Circuit
RoHS Compliant
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Physical
Case Size
Case Material
Weight
1.08 x 1.08 x 0.38 Inches (25.4 x 25.4 x 9.6 mm)
Metal With Non-Conductive Base (UL94-V0)
0.52 Oz (15g)
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Conditions
24 VDC Input
48 VDC Input
Lead Temperature
Internal Power Dissipation
1.5 mm From Case For 10 Sec
All Models
Min.
1.0
Min.
-0.7
-0.7
Typ.
Max.
40.0
80.0
300
450
ºC
mW
Typ.
Max.
Units
MHours
Units
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
I501RU
I502RU
I503RU
I504RU
I505RU
I506RU
I507RU
I508RU
I511RU
I512RU
I513RU
I514RU
I515RU
I516RU
I517RU
I518RU
Input
Output
Efficiency
Voltage (VDC)
Current (mA)
Voltage Current
Current
(%, Typ)
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min)
24
9.0 - 36.0
270
25
5.0
1,000
100
77
24
9.0 - 36.0
260
25
12.0
420
42
80
24
9.0 - 36.0
257
25
15.0
333
33
81
24
9.0 - 36.0
285
25
24.0
200
20
73
24
9.0 - 36.0
278
25
±5.0
±500
±50
75
24
9.0 - 36.0
270
25
±12.0
±200
±20
77
24
9.0 - 36.0
264
25
±15.0
±166
±16
79
24
9.0 - 36.0
257
25
±24.0
±104
±10
81
48
18.0 - 72.0
131
20
5.0
1,000
100
79
48
18.0 - 72.0
127
20
12.0
420
42
82
48
18.0 - 72.0
122
20
15.0
333
33
85
48
18.0 - 72.0
121
20
24.0
200
20
86
48
18.0 - 72.0
139
20
±5.0
±500
±50
75
48
18.0 - 72.0
133
20
±12.0
±200
±20
78
48
18.0 - 72.0
127
20
±15.0
±166
±16
82
48
18.0 - 72.0
122
20
±24.0
±104
±10
85
Fuse Rating
Slow-Blow
(mA)
700
700
700
700
700
700
700
700
350
350
350
350
350
350
350
350
Notes:
1. When measuring output ripple, it is recommended that an external ceramic
capacitor (approx approx 1 µF to 10 µF) be placed from the +Vout pin to the
-Vout pin for single output units and from each output to common for dual
output units.
2. These units should not be operated with a load under 10% of full load. Opera-
tion at no-load
may cause damage to the unit.
3. These converters are specified for operation without external components.
However, in some applications the addition of input/ouput capacitors will
enhance stability and reduce output ripple. Recommended capacitor values
are:
Derating Curve
Vin
24 VDC
48 VDC
Input
Capacitor
100 µF
100 µF
Vout
5 VDC
12 VDC
15 VDC
24 VDC
Output
Capacitor
100 µF
100 µF
100 µF
100 µF
For applications requiring very low output noise levels, a simple LC filter should
be effective.
4. Dual output units may be connected to provide
a 10V, 24V, 30V or 48 VDC output. To do this,
connect the load across the positive (+Vout) and
negative (-Vout) outputs and float the output common.
5. It is recommended that a fuse be used on the input
of a power supply for protection. See the Model
Selection table above for the correct rating.
Mechanical Dimensions
Pin Connections
Pin
1
2
3
Single
+Vin
-Vin
+Vout
Dual
+Vin
-Vin
+Vout
Pin
4
5
Single
No Pin
-Vout
Dual
Common
-Vout
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.01 (
±
0.25)
•
Pin 1 is marked by a “dot” on the top of the unit
MicroPower Direct
www.micropowerdirect.com
•
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com