SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
90-264Vac typical.
Input Connector:
Wallmount Format.
WM1/ WM2 (USA/Japan), WM3(Euro-Stecker).
WM5 (UK) / WM6 (Australia).
Input Frequency:
47-63Hz.
Inrush Current:
28A @230Vac typical.
Input Current:
0.6A @115Vac/0.3A @230Vac.
Dielectric Withstand:
Meet IEC60950.
EMI:
Meet EN55022/ FCC Class B.
Hold-up Time:
8mS @115Vac typical.
35mS @230Vac typical.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
20-36 Watts typical.
Output Connector & Cord:
Optional.
Line Regulation:
0.1% typical.
Load Regulation:
±1.5-3% typical.
Noise & Ripple:
1.0% typical peak to peak.
OVP:
Built-in, Zener diode clamping.
Adjustability:
Factory set.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
Operating Temperature:
0 °C to room temperature.
Storage Temperature:
-20 to +85°C.
Temperature Coefficient:
0.04% /°C.
Cooling:
Free air convection.
Construction:
Impact resistant thermo-plastic
enclosure case.
Wallmount Format.
GENERAL SPECIFICATION
Efficiency:
71-85% typical.
Switching Frequency:
Approximate 70K Hz.
Circuit Topology:
Fixed Frequency Flyback circuit.
Transient Response:
Output voltage returns in less than
3mS following a 25% load change.
Safety Standard:
Meet UL60950/ EN60950 Class I & II.
Power Density:
2.67 Watts / Cubic inch.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
(4) Due to requests in market and advances in technology, specifications subject to change without notice
For the details of safety approval, please consult the factory.
-25-

HES25-150200-6 Related Products

HES25-150200-6 HES25-360100-6 HES25-240150-3 HES25-180166-1 HES25-300120-5 HES25-050400-2 HES25-033500-1 HES25-090270-3 HES25
Description AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 20-36 WATTS SWITCHING POWER SUPPLIES
Understanding of MSP430G2553
Looking back on the period before school started, it seems that I didn’t do anything except learning MSP430G2553.The software used is CCS. Installing the software is really a headache. I installed it ...
fish001 Microcontroller MCU
Pathfinding.
Does anyone know the standard textbooks for the self-study examination of linear electronic circuits in Shandong Province for the electronic technology major (junior college)? Previous years’ test que...
lzhzhz Analog electronics
What type of sensors are used in combustible gas alarms?
I need help. I want to ask what type of sensors are normally used in flammable and toxic gas alarms?...
njshunsheng01 Sensor
Power Management Solutions for Multimedia Mobile Phones
I saw a good article about IC design, which gave some new ideas to students studying electronics.Multimedia applications such as mobile TV, mobile gaming, and audio playback present a huge challenge t...
soff Power technology
SUNPLUS launches 8-bit industrial-grade MCU learning board
Sunplus Technology (SUNPLUS) recently announced: Sunplus Technology (sunplus) launched the 8-bit industrial-grade MCU series - SPMC65 series learning board. The SPMC65 series MCU is an industrial-grad...
rain MCU
MSP430 UART bit error problem
Now I use the UART (full duplex, baud rate 9600) of MSP430F437, and found that there is a bit error phenomenon. For example, when the program sends "AA", the actual monitored data is "AC".The relevant...
cai5143 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2591  2640  525  22  1318  53  54  11  1  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号