EEWORLDEEWORLDEEWORLD

Part Number

Search

GXM2S.F10A104

Description
Absolute encoders - SSI
File Size627KB,4 Pages
ManufacturerIVO ( Baumer )
Websitehttp://www.ivo.de/
Download Datasheet View All

GXM2S.F10A104 Overview

Absolute encoders - SSI

Absolute encoders - SSI
End shaft max. ø14 mm
Optical multiturn encoders 14 bit ST / 12 bit MT
GXM2S - SSI
Features
– Encoder multiturn / SSI
– Optical sensing
– Resolution: singleturn 14 bit, multiturn 12 bit
– End shaft ø12 mm / ø14 mm
– Electronic setting of zero point
– Permanent check of code continuity
– Counting direction input
– Suitable for high positive and negative accelerations
– Available with additional incremental output
GXM2S with end shaft
Technical data - electrical ratings
Voltage supply
Consumption w/o load
Initializing time (typ.)
Interfaces
Steps per turn
Number of turns
Incremental output
Absolute accuracy
Sensing method
Code
Code sequence
Inputs
10...30 VDC
≤50 mA (24 VDC)
20 ms after power on
SSI, Incremental A 90° B
(optional)
16384 / 14 bit
4096 / 12 bit
2048 pulses A90°B
+ inverted
±0.025°
Optical
Gray or binary
CW/CCW coded by connection
SSI clock
Control signals UP/DOWN and
zero
SSI data linedriver RS485
Diagnostic and incremental
outputs
DIN EN 61000-6-2
DIN EN 61000-6-4
Self-diagnosis
Code continuity check
Multiturn sensing
UL approval / E63076
Reverse polarity protection Yes
Technical data - mechanical design
Housing
Shaft
Protection DIN EN 60529
Operating speed
Starting torque
Rotor moment of inertia
Materials
Operating temperature
Relative humidity
Resistance
ø58 mm
ø12 mm end shaft
ø14 mm end shaft
IP 54
≤6000 rpm (mechanical)
≤6000 rpm (electric)
≤0.015 Nm IP 54
20 gcm²
Housing: steel
Flange: steel
-25...+85 °C
-40...+85 °C (optional)
95 % non-condensing
Subject to modification in technic and design. Errors and omissions excepted.
29/10/2008
DIN EN 60068-2-6
Vibration 10 g, 16-2000 Hz
DIN EN 60068-2-27
Shock 100 g, 6 ms
600 g
Connector, 12-pin
Output circuit
Weight approx.
E-connection
Interference immunity
Emitted interference
Diagnostic functions
Approval
1
www.baumerivo.com
Functions with parameters and no return value
The function printfline will display the same line each time it is called. The same is true for the value function. We could also have the calling function read the data from the terminal and pass it ...
sunplusedu2012a Linux and Android
Has anyone used a dual-channel single-pole double-throw analog switch?
I want to choose a D-SPDT. I don't have any requirements for the switching speed. The signal response speed after the channel switching is required to be about 10K~100K. The size should not be too lar...
zorro1978 Microcontroller MCU
Ultra-low power quad 2-input NOR gate
Can you recommend any ultra-low power quad 2-input NOR gate models?...
yyhhgg Test/Measurement
FilterSolutions User's Guide The simulated filter that has been practiced is pretty good
FilterSolutions User's Guide This is the original English version to help you read it....
btty038 RF/Wirelessly
May I ask what is the adc_app_volt_measure tool in the starterware of TI's sysbios_ind_sdk_02.01.00.01 package?
I burned the compiled adc_app_volt_measure project into the board and found that the data read out showed 1.8v and 0v. The values displayed did not change when the voltages on adc0 channels 0 and 1 we...
LCZ DSP and ARM Processors
How to use 485 communication with MicroPython
Is there any useful one? Please give me some advice....
zhaoqx MicroPython Open Source section

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 222  2843  1140  685  1062  5  58  23  14  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号