EEWORLDEEWORLDEEWORLD

Part Number

Search

D3V-016-2C23

Description
Snap Acting/Limit Switch, SPST, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,14 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

D3V-016-2C23 Online Shopping

Suppliers Part Number Price MOQ In stock  
D3V-016-2C23 - - View Buy Now

D3V-016-2C23 Overview

Snap Acting/Limit Switch, SPST, Momentary, 0.1A, 8VDC, 5.6mm, Quick Connect Terminal, Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

D3V-016-2C23 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke5.6 mm
Actuator typeHINGE ROLLER LEVER
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
Contact (AC) maximum rated R load.1A@125VAC
Maximum contact current (AC)0.1 A
Maximum contact current (DC)0.1 A
Contact (DC) maximum rated R load.1A@8VDC
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)8 V
Electrical life500000 Cycle(s)
Manufacturer's serial numberD3V
Installation featuresPANEL MOUNT
Maximum operating force0.29 N
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
Maximum pre-travel4 mm
sealIP00
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
Miniature Basic Switch
D3V
Reliable Basic Switch with External Lever
• Available by 0.1 A, 6 A, 11 A, 16 A and 21 A models, all with
self-cleaning contacts. 0.1 A utilizes gold alloy crossbar
contacts for high reliability at low loads.
• Available with internally or externally fitted levers, and 2 fix-
ing positions for external levers.
• Conforms to EN61058-1 UL1054.
• Right-angle plunger option available in some models.
• RoHS Compliant.
Ordering Information
Model Number Legend
D3V-@@@@-@@@-@-@
1 2 3 4
5 6 7
8
9
6. Terminals
A:
Solder/quick-connect terminal (#187)
C2: Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
(optional without surge creepage tab flush around
terminals.)
7. Maximum Operating Force
5:
1.96 N {200 gf}
4A: 1.23 N {125 gf}
4:
0.98 N {100 gf}
3:
0.49 N {50 gf}
2:
0.25 N {25 gf}
Note:
These values are for the plunger models.
8. Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
9. Special Code
None: Standard
H:
High temperature (125° C)
E:
Special rating: 21 (8) A
T:
High temperature (200
°
C)
1. Ratings
21: 20 (4) A at 250 VAC
16: 16 (3) A at 250 VAC
11: 11 (3) A at 250 VAC
6:
6 (2) A at 250 VAC
01: 0.1 A at 125 VAC
2. Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
3. Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
4. Hinge Position
None: Internal/Far from plunger
M:
External/Far from plunger
K:
External/Near plunger
5. Contact Form
1:
SPDT
2:
SPST-NC
3:
SPST-NO
Miniature Basic Switch
D3V
1
【RT-Thread Reading Notes】Virtual File System
[i=s] This post was last edited by jj1989 on 2019-4-27 18:47 [/i] [size=4] [md]# 【RT-Thread Reading Notes】Virtual File System## Preface I have been paying attention to the RT-Thread embedded real-time...
jj1989 Embedded System
meaning
[color=red]@What is the function[/color]const uchar EnAAReg[2] @ 0x1046 = {0x21, //Auto-response register address 0x00 //Disable auto-response for all channels};...
ljk926 Microcontroller MCU
How to set the cycle time of the ST7920 parallel enable signal of LCD12864 (ST7920 with font library)
Dear experts, could you please tell me how to set the cycle time of the ST7920 parallel enable signal of LCD12864 (ST7920 with font library)?...
cjs520 Microcontroller MCU
I need help with I2C read and write programs for DSP28027.
[align=left][color=rgb(0,0,0)][backcolor=rgb(255,255,255)]The following is a program I wrote based on LMP9100 and the routines provided by TI. The routines provided by TI use interrupts, but mine do n...
重新开始 Microcontroller MCU
My ideal
My ideal is to be healthy, have enough money to spend, have no worries, have novels to read, not get fat, not get old, have two or three good friends, not get dizzy, not get stomachaches, not be distu...
wanghlady Talking
Why are the results of the circuits in the simulation book different? It's so annoying.
Can you please help me, this is all from the book, but why is it different? ? I used the same transistor and it still doesn't work!...
零下12度半 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2006  689  399  2426  2059  41  14  9  49  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号