EEWORLDEEWORLDEEWORLD

Part Number

Search

D38999/20KG41PB-LC

Description
MIL Series Connector, 41 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size131KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

D38999/20KG41PB-LC Overview

MIL Series Connector, 41 Contact(s), Stainless Steel, Male, Crimp Terminal, Receptacle

D38999/20KG41PB-LC Parametric

Parameter NameAttribute value
MakerAmphenol
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSTANDARD: MIL-DTL-38999, POLARIZED, EMI SHIELDED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationGOLD (50)
Contact completed and terminatedGOLD (50)
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
empty shellYES
Environmental characteristicsCORROSION/ENVIRONMENT/FIRE/MOISTURE RESISTANT
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceYES
Manufacturer's serial numberD38999/20
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing sizeG
Termination typeCRIMP
Total number of contacts41
Base Number Matches1
TVP00R (D38999/20) - Crimp, Metal
CTVP00R (D38999/20) - Crimp, Composite
Wall Mounting Receptacle
PART #
To complete,
see how to order
pages 25-27.
Connector
Type
Shell
Style
Amphenol
Aerospace
Service
Shell Size
Class
& Insert Arrg
Contact Alternate
Special
Type
Position
Variations
38999
TVP
TVPS
TVPS
TVPS
CTVP
CTVPS
D38999/
00
RW
00
RK
00
RF
00
RS
00
RW
METAL
00
RF
20
X
9-35
X-X
X-X
X-X
X-X
X-X
X-X
P
X
X
X
X
X
X
B
X
X
X
X
X
X
(453)
(XXX)
(XXX)
(XXX)
(XXX)
(XXX)
NA
S
2 PLACES
R
1
2 PLACES
R
2
2 PLACES
B
THREAD
LL (TV)
LL
1
(CTV)
M (TV)
M
1
(CTV)
AA
L (TV)
L
1
(CTV)
V THREAD
VIEW D
FOR SIZE 8 COAXIAL ONLY,
RELATIVE TO –A–
.861 MAX
21.87 MAX
(TV)
PANEL HOLE
DIMENSIONS
III
HD
Dualok
II
I
SJT
A
ccessories
A
quacon
H
erm/Seal
PCB
HIgH
SPEED
.909 MAX
23.09 MAX
(CTV)
VIEW D
FOR SIZE 8 TWINAX ONLY,
RELATIVE TO –A–
D
A
1
BACK PANEL
MOUNTING
Fiber
Optics
Contacts
Cables
Connectors
TT
4 PLACES
.005 M
.13 M
T
4 PLACES
RED
BAND†
BLUE
BAND††
Z (TV)
Z
1
(CTV)
–A–
EMI Filter
Transient
1.037 MAX
26.34 MAX
(TV)
1.240 MAX
31.50 MAX
A
2
1.084 MAX
27.53 MAX
(CTV)
FRONT PANEL
MOUNTING
Matrix 2
26482
† Red band indicates fully mated
†† Blue band indicates rear release contact retention system
Inches
MS
B Thread
Shell Class 2A
L
1
Shell Size 0.1P=0.3L- L Max. Max.
Size Code TS (Plated) (TV) (CTV)
9
A
.6250
.469 .514
11
13
15
17
19
21
23
25
B
C
D
E
F
G
H
J
.7500
.8750
1.0000
1.1875
1.2500
1.3750
1.5000
1.6250
.469
.469
.469
.469
.469
.500
.500
.500
.514
.514
.514
.514
.514
.545
.545
.545
1
M
M
1
+.000 +.000
–.005 –.005
(TV) (CTV)
.820 .773
.820
.820
.820
.820
.820
.790
.790
.790
.773
.773
.773
.773
.773
.741
.741
.741
R
1
.719
.812
.906
.969
1.062
R
2
.594
.719
.812
.906
.969
A
1
A
2
AA Max.
LL
1
Z.
Z
Back Front
Panel
+.006 LL1
T
Max. Max. Panel Panel
Thick- –.000 ±.005 TT
S Max. ±.008 (TV) (CTV) Mount Mount
ness
(TV) (CTV) ±.008
.948 .128 .153 .198 .650
.510
.234
.905 .908 .216
1.043
1.137
1.232
1.323
1.449
1.575
1.701
1.823
.128
.128
.128
.128
.128
.128
.154
.154
.153
.153
.153
.153
.153
.183
.183
.183
.198
.198
.198
.198
.198
.228
.228
.228
.800
.910
1.040
1.210
1.280
1.410
1.530
1.660
1
83723 III
Matrix|Pyle
.620
.740
.900
1.010
1.130
1.250
1.360
1.470
2
.234
.234
.234
.234
.234
.204
.204
.204
.905
.905
.905
.905
.905
.905
.905
.905
.908
.908
.908
.908
.908
.904
.904
.904
.194
.194
.173
.194
.194
.194
.242
.242
26500
Pyle
1.156 1.062
1.250 1.156
1.375 1.250
1.500 1.375
Crimp Rear
Release
Matrix
Class L
5015
Millimeters
22992
MS
M
Shell
L
1
M +.00 +.00
Shell Size L Max. Max.
–.13
–.13
Size Code (TV) (CTV) (TV) (CTV)
9
A
11.91 13.06 20.83 19.63
11
13
15
17
19
21
23
25
B
C
D
E
F
G
H
J
11.91
11.91
11.91
11.91
11.91
12.70
12.70
12.70
13.06
13.06
13.06
13.06
13.06
13.84
13.84
13.84
20.83
20.83
20.83
20.83
20.83
20.07
20.07
20.07
19.63
19.63
19.63
19.63
19.63
18.82
18.82
18.82
R
1
18.26
20.62
23.01
24.61
26.97
29.36
31.75
34.93
38.10
Z.
R
2
S
T
V Thread Max. Z
1
Max.
Max. ±.20
Metric
(TV) (CTV)
15.09 24.1 3.25 M12X1-6g 3.89
5.03
18.26
20.62
23.01
24.61
26.97
29.36
31.75
34.93
26.5
28.9
31.3
33.7
36.9
40.1
43.3
46.4
3.25
3.25
3.25
3.25
3.25
3.25
3.91
3.91
M15X1-6g 3.89
M18X1-6g 3.89
M22X1-6g 3.89
M25X1-6g 3.89
M28X1-6g 3.89
M31X1-6g 4.65
M34X1-6g 4.65
M37X1-6g 4.65
5.03
5.03
5.03
5.03
5.03
5.79
5.79
5.79
A
A
LL
Back Front
+.15
LL1
Panel Panel
AA
–.00
±.13
Mount Mount Max. (TV) (CTV)
16.66 13.11 5.94 22.99 23.06
20.22
23.42
26.59
30.96
32.94
36.12
39.29
42.47
15.88
19.05
23.01
25.81
28.98
32.16
34.93
37.69
5.94
5.94
5.94
5.94
5.94
5.18
5.18
5.18
22.99 23.06
22.99 23.06
22.99 23.06
22.99 23.06
22.99 23.06
22.99 22.96
22.99 22.96
22.99 22.96
TT
±.20
5.49
4.93
4.93
4.39
4.93
4.93
4.93
6.15
6.15
Back-
Shells
Options
Others
All dimensions for reference only
Designates true position dimensioning
Contact Amphenol Aerospace for more information at 800-678-0141 • www.amphenol-aerospace.com
29
Design and implementation of a controller for a real vehicle collision speed control system
Abstract: In the real vehicle magnetic collision test, the vehicle speed directly affects the test results. In order to fundamentally solve the difficulties in speed control caused by the aging and ti...
frozenviolet Automotive Electronics
Please tell me about protues keil 8086?
The graduation project assigned by the teacher is to simulate 8086 in protues. In other words, the processor in protues is 8086. When the ".hex" target file needs to be loaded, it needs to be generate...
jiemei6617 Embedded System
Consultation Post
[font=宋体]The separation of electron and hole wave functions in LED quantum wells will inhibit recombination efficiency. How can we achieve the suppression of non-radiative recombination without affect...
大先森Mr.kai LED Zone
How to design traffic lights with FPGA to achieve emergency situations
It would be best if there is code, the more detailed the better. Thank you...
华克钊 FPGA/CPLD
Danfoss inverter fault alarm?
Danfoss inverter VLT2800 11KW fan load, I see terminals 1-2 NO, 1-3 NC, after 1-3 is connected to Mitsubishi FX series PLC, the inverter has input signal when it is not powered, but it does not after ...
eeleader Industrial Control Electronics
Solution to MSP430 ADC10 multi-channel multiple sampling problem
Three channels are sampled, and each channel needs to sample 3 different voltage values. First, channel 2 samples 3 different voltages, then channel 3, and channel 4. However, every time channel 2 sam...
xxdong Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1035  2159  2265  447  2843  21  44  46  9  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号