EEWORLDEEWORLDEEWORLD

Part Number

Search

5962-9308901HZC

Description
DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid,
CategoryPower/power management    The power supply circuit   
File Size335KB,15 Pages
ManufacturerCrane Co.
Download Datasheet Parametric View All

5962-9308901HZC Overview

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid,

5962-9308901HZC Parametric

Parameter NameAttribute value
MakerCrane Co.
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresADDITIONAL -12V OUTPUT AVAILABLE
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage40 V
Minimum input voltage16 V
Nominal input voltage28 V
JESD-30 codeR-MDMA-G20
JESD-609 codee4
Number of functions1
Output times2
Number of terminals20
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Maximum output voltage12.12 V
Minimum output voltage11.88 V
Nominal output voltage12 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Certification statusNot Qualified
Filter levelMIL-PRF-38534 Class H
surface mountYES
technologyHYBRID
Temperature levelMILITARY
Terminal surfaceGOLD
Terminal formGULL WING
Terminal locationDUAL
Maximum total power output5 W
Fine-tuning/adjustable outputNO
Base Number Matches1
Crane Aerospace & Electronics Power Solutions
MSA/MGA Single and Dual DC-DC Converters
28 Volt input – 5 Watt
Features
small size, 1.16 in
2
(7.46 cm
2
) - Msa
surface mount package - MGa
• –55° to +125°C operation
• 16 to 40 VDC input
• Fully isolated
• 50 V for 50 ms transient protection
• Fixed high frequency switching
• Inhibit function
• Indefinite short circuit protection
VDC O
utput
MoDels
SINGLE
5
5.2 (MSA only)
12
15
DUAL
±5
±12
±15
• Up to 76% efficiency
Description
The Interpoint™ MSA Series™ and MGA Series™ of dc-dc
converters provide up to 5 watts of output power over the full
military temperature range with up to 76% efficiency. Thick-film
hybrid techniques provide military/aerospace reliability levels and
optimum miniaturization.
The converters are offered with standard screening, “ES”
screening, or fully compliant to “883” MIL-PRF-38534 Class H
screening. Standard microcircuit drawings (SMD) are available.
See “Table 12: Element Evaluation” on page 14 and “Table 13:
Environmental Screening” on page 15 for screening options
and descriptions.
The converters are switching regulators that use a flyback
converter design with a constant switching frequency of 550 kHz
typical. They are regulated, isolated units using a pulse width
modulated topology and are built as high reliability thick-film
hybrids. Isolation between input and output circuits is provided
with a transformer in the forward power path and an optical
link in the feedback control loop. Excellent input line transient
response and audio rejection is achieved by an advanced feed-
forward compensation technique. Negative output regulation is
maintained by tightly coupled magnetics. Up to 4 watts, 80% of
the total output power, is available from either output, provided
that the opposite output is simultaneously carrying 20% of the
total power in order to maintain the specified regulation on the
negative output. A predictable current limit is accomplished by
direct monitoring of the output load current, which results in a
constant current output. Internal input and output filters eliminate
the need for external capacitors for stable operation. Output filter
examples in “Figure 3: Low Noise Output Filter MSA and MGA
Single Output Models” on page 3 and “Figure 4: Low Noise
Output Filter MSA and MGA Dual Output Models” on page 3
provide suggested solutions for systems where very low output
ripple is required.
W
iDe
v
oltage
r
ange
C
onverter
D
esign
The MSA converters are designed to provide full power operation
over a full 16 to 40 VDC voltage range. Operation below 16 volts,
including MIL-STD-704E emergency power conditions is possible
with derated power. Low-line drop out graphs, “Figure 17” on
page 10 and “Figure 23” on page 11, graphs provide more
information.
The feed-forward compensation system rovides excellent
p
dynamic response and noise rejection. Audio rejection is typically
50 dB. The minimum to maximum step line transient response is
typically less than 1%.
i
mproveD
D
ynamiC
r
esponse
Crane Aerospace & Electronics
Power Solutions – Interpoint Products
10301 Willows Rd. NE, Redmond, WA 98052
+1.425.882.3100 • power@crane-eg.com
www.craneae.com/interpoint
Page 1 of 15
MSA_MGA Rev AC - 2013.06.13
The filter capacitor in the picture, 4.7uF/400V electrolytic capacitor, will bulge when it is old, causing the device to explode?
[font=宋体][size=3]Question: Will the filter capacitor 4.7uF/400V electrolytic capacitor in the picture swell and explode when it is old? [/size][/font]...
pengdaiyun Analog electronics
zuanfentie
...
wanglicha Embedded System
A portrait of the life of a Taiwanese IC engineer
Taiwan's IC design industry is already the world's second largest, second only to the United States. In 2001, Taiwan's IC design industry was estimated to have created a production value of NT$139 bil...
绿茶 Talking about work
[Xin version TALK] Are you still eagerly waiting for red envelopes and year-end bonuses?
I just saw a post about Renjianbucha, which was posted by an old forum friend RF Haishijun. Asking about the year-end of 2019, naturally few people answered this sad question. Most people answered tha...
辛昕 Talking
Power supply circuit design, please give me some advice
I need to convert 220V AC voltage into 5V and 3.3V DC voltage output for the power supply voltage of the microcontroller. How should I achieve this? Please give me some advice. It's urgent....
秋枫叶落时 Power technology
I'm using STM32F103RCT6 recently. I used software to simulate 10 IIC 24C02s. Is it necessary for the clock line and data line to be of equal length?
I'm using STM32F103RCT6 recently. I used software to simulate 10 IIC 24C02s. Do the clock and data lines need to be the same length? Do the impedances need to be equal? How fast is the transmission ra...
QWE4562009 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1998  2076  861  1303  373  41  42  18  27  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号