EEWORLDEEWORLDEEWORLD

Part Number

Search

5962-8959201YX

Description
Line Transceiver, 1 Func, 1 Driver, 1 Rcvr, 1.270 X 1.270 INCH, 0.200 INCH HEIGHT, FP-24
CategoryAnalog mixed-signal IC    Drivers and interfaces   
File Size166KB,18 Pages
ManufacturerCobham PLC
Download Datasheet Parametric View All

5962-8959201YX Overview

Line Transceiver, 1 Func, 1 Driver, 1 Rcvr, 1.270 X 1.270 INCH, 0.200 INCH HEIGHT, FP-24

5962-8959201YX Parametric

Parameter NameAttribute value
MakerCobham PLC
package instruction1.270 X 1.270 INCH, 0.200 INCH HEIGHT, FP-24
Reach Compliance Codeunknown
ECCN codeEAR99
Differential outputYES
Number of drives1
Input propertiesDIFFERENTIAL
Interface integrated circuit typeLINE TRANSCEIVER
JESD-30 codeS-XDFP-F24
Number of functions1
Number of terminals24
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package body materialUNSPECIFIED
encapsulated codeDFP
Package shapeSQUARE
Package formFLATPACK
Certification statusNot Qualified
Maximum receive delay450 ns
Number of receiver bits1
Maximum seat height5.08 mm
Maximum supply voltage5.5 V
Minimum supply voltage4.5 V
Nominal supply voltage5 V
Supply voltage 1-max15.75 V
Mains voltage 1-minute11.4 V
surface mountYES
Temperature levelMILITARY
Terminal formFLAT
Terminal pitch2.54 mm
Terminal locationDUAL
maximum transmission delay550 ns
Base Number Matches1
NOTICE OF REVISION (NOR)
(See MIL-STD-480 for instructions)
This revision described below has been authorized for the document listed.
DATE (YYMMDD)
91-11-06
Form Approved
OMB No. 0704-0188
Public reporting burden for this collection is estimated to average 1 hour per response, including the time for reviewing instructions, searching
existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments
regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to
Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington,
VA 22202-4302, and to the Office of Information and Regulatory Affairs, Office of Management and Budget, Washington, DC 20503.
1. ORIGINATOR NAME AND ADDRESS
Defense Electronics Supply Center
Dayton, Ohio 45444-5277
2. CAGE CODE
67268
4. CAGE CODE
67268
6. TITLE OF DOCUMENT
MICROCIRCUIT, DIGITAL, LOW POWER, SINGLE CHANNEL, DRIVER-RECEIVER,
HYBRID
7. REVISION LETTER
(Current) A
8. ECP NO.
(New) B
3. NOR NO.
5962-R034-92
5. DOCUMENT NO.
5962-89592
9. CONFIGURATION ITEM (OR SYSTEM) TO WHICH ECP APPLIES
ALL
10. DESCRIPTION OF REVISION
Sheet 1: Revisions ltr column; add "B"
Revisions description column; add "Changes in accordance with
NOR 5962-R034-92".
Revisions date column; add "91-11-06".
Sheet 7: Table I, Add subgroup 5 to the I
CC
-100 and I
EE
-100 tests and remove the temperature reference in the
conditions block for these tests.
11. THIS SECTION FOR GOVERNMENT USE ONLY
a. CHECK ONE
A
X
B
EXISTING DOCUMENT SUPPLEMENTED
BY THIS NOR MAY BE USED IN
MANUFACTURE.
b. ACTIVITY AUTHORIZED TO APPROVE
CHANGE FOR GOVERNMENT
DESC-ECT
12. ACTIVITY ACCOMPLISHING REVISION
DESC-ECT
DD Form 1695, JUL 88
A B
REVISED DOCUMENT MUST BE
RECEIVED BEFORE MANUFACTURER
MAY INCORPORATE THIS CHANGE.
A B
CUSTODIAN OF MASTER DOCUMENT
SHALL MAKE ABOVE REVISION AND
FURNISH REVISED DOCUMENT TO:
SIGNATURE AND TITLE
Greg Lude
Branch Chief
DATE (YYMMDD)
91-11-06
REVISION COMPLETED (Signature)
DATE (YYMMDD)
Shelly M. Jenkins
91-11-06
Previous editions are obsolete.
Complete signal analysis
A book about signal integrity analysis, I hope it will be helpful to colleagues who do circuit analysis...
xingnuolgsx Analog electronics
Analog Front End AFE
Analog Front End AFEThe analog front end AFE has always been monopolized by TI, ADI, MICROCHIP, and Cirrus Logic. Electrochemistry, electrochemical gas sensors, potentiostat/amperometry/voltammetry/cy...
QWE4562009 Test/Measurement
Is there any special way to route the wiring of this type of seat?
[i=s]This post was last edited by btty038 on 2018-11-23 08:41[/i] Is there any special way to route the wiring of this type of seat?...
btty038 PCB Design
Today, did you say I love you?
Today is a romantic day, May 20th, which sounds like "I love you". On such a day, has there ever been someone in your heart that you always miss and pursue, but she has never found you? Youth sometime...
maylove Talking
How to learn embedded system? What is its development prospect?
Hello everyone, I am a college student. Facing the fierce competition in today's society, we college students are really at a loss. I want to make a career plan and learn more about embedded systems. ...
shenlanshanshan Embedded System
It's hard to get a sample...
I need some samples to test. I need a few MSP430FR5870s. I've tried so hard but still can't get them. I searched on Taobao before and found all kinds of films. This film has been discontinued, but the...
yl20084784 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 819  2  1792  300  2377  17  1  37  7  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号