51726-11211400A0LF

Description
Board Connector, Right Angle, Solder Terminal, Locking
CategoryThe connector    The connector   
File Size232KB,3 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

51726-11211400A0LF Overview

Board Connector, Right Angle, Solder Terminal, Locking

51726-11211400A0LF Parametric

Parameter NameAttribute value
MakerAmphenol
Reach Compliance Codecompliant
body width0.574 inch
subject depth0.93 inch
Connector typeBOARD CONNECTOR
Contact completed and terminatedTIN
Contact materialPHOSPHOR BRONZE
Contact resistance20 mΩ
Contact styleHYBRID
Dielectric withstand voltage2500VDC V
Durability200 Cycles
maximum insertion force.973 N
Insulation resistance500000000 Ω
insulator materialGLASS FILLED THERMOPLASTIC
Manufacturer's serial number51746
Mixed contactsYES
Installation option 1LOCKING
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of connectorsONE
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
reliabilityCOMMERCIAL
Terminal length0.135 inch
Termination typeSOLDER
Evacuation force-minimum value.17792 N
Base Number Matches1
PDM: Rev:L
STATUS:
Released
Printed: Dec 20, 2010
.
Hardware Engineer's Handbook - Complete
...
无关风月007 Analog electronics
New book arrived, show it to me
I was lucky enough to get the new book by [url=https://home.eeworld.com.cn/space.php?uid=66265&op=bbs]zhaojun_xf[/url]. First of all, I would like to express my gratitude for the award: Thank you EEwo...
季夏木槿 NXP MCU
ADI Motor Control Solutions—Servo Control
...
gaoyang9992006 Analog electronics
How to start the design of adjustable voltage regulated power supply application
The control chip of the DC regulated power supply adopts the relatively mature imported components, and the power components adopt the latest high-power devices developed internationally. The adjustab...
fish001 Analogue and Mixed Signal
How far can the analog input signal line be from the PLC?
How far can the analog input signal line be from the PLC?...
STORMc 51mcu
PADS9.1 was fully installed in less than a minute with few problems
PADS9.1 was fully installed in less than a minute. I have used this software for several months with few problems. It is OK. I would like to share it with you....
毛承玲 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1415  54  1468  2534  1447  29  2  30  52  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号