Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3015A Multi-Conductor - 300V Power-Limited Tray Cable
For more Information
please call
1-800-Belden1
General Description:
22 AWG pairs stranded (7x30) bare copper conductors, twisted pairs, PVC insulation, individually shielded
plus an overall Beldfoil® shield (100% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors # Pairs AWG Stranding Conductor Material
50
1
22
22
7x30
7x30
BC - Bare Copper
BC - Bare Copper
Total Number of Conductors:
101
Insulation
Insulation Material:
Insulation Material
PVC - Polyvinyl Chloride
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Inner Shield Drain Wire AWG:
AWG
22
Inner Shield Drain Wire Stranding:
Inner Shield Drain Wire Conductor Material:
7x30
TC - Tinned Copper
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
22
7x30
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .075
Outer Jacket Ripcord:
Yes
Overall Cable
Overall Nominal Diameter:
1.050 in.
Pair
Pair Color Code Chart:
Number
1
2
Color
Black & White and Numbered 1
Black & White and Numbered 2
Page 1 of 4
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3015A Multi-Conductor - 300V Power-Limited Tray Cable
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
Black & White and Numbered 3
Black & White and Numbered 4
Black & White and Numbered 5
Black & White and Numbered 6
Black & White and Numbered 7
Black & White and Numbered 8
Black & White and Numbered 9
Black & White and Numbered 10
Black & White and Numbered 11
Black & White and Numbered 12
Black & White and Numbered 13
Black & White and Numbered 14
Black & White and Numbered 15
Black & White and Numbered 16
Black & White and Numbered 17
Black & White and Numbered 28
Black & White and Numbered 19
Black & White and Numbered 20
Black & White and Numbered 21
Black & White and Numbered 22
Black & White and Numbered 23
Black & White and Numbered 24
Black & White and Numbered 25
Black & White and Numbered 26
Black & White and Numbered 27
Black & White and Numbered 28
Black & White and Numbered 29
Black & White and Numbered 30
Black & White and Numbered 31
Black & White and Numbered 32
Black & White and Numbered 33
Black & White and Numbered 34
Black & White and Numbered 35
Black & White and Numbered 36
Black & White and Numbered 37
Black & White and Numbered 38
Black & White and Numbered 39
Black & White and Numbered 40
Black & White and Numbered 41
Black & White and Numbered 42
Black & White and Numbered 43
Black & White and Numbered 44
Black & White and Numbered 45
Black & White and Numbered 46
Black & White and Numbered 47
Black & White and Numbered 48
Black & White and Numbered 49
Black & White and Numbered 50
Communication Wire Orange
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-30°C To +105°C
105°C
1330 lbs.
10.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
PLTC, ITC, CMG
Page 2 of 4
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3015A Multi-Conductor - 300V Power-Limited Tray Cable
NEC/(UL) Specification:
CEC/C(UL) Specification:
EU Directive 2011/65/EU (ROHS II):
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
PLTC, ITC, CMG
CMG
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
UL Flame Test:
C(UL) Flame Test:
IEEE Flame Test:
ICEA Flame Test:
UL1685 FT4 Loading
FT4
1202
T-29-520
Suitability
Suitability - Indoor:
Suitability - Outdoor:
Suitability - Burial:
Sunlight Resistance:
Yes
Yes
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/ft)
.21
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
15
Max. Operating Voltage - UL:
Voltage
300 V RMS (PLTC
CMG)
150 V RMS (ITC)
Max. Recommended Current:
Current
2.4 Amps per conductor @ 25°C
Put Ups and Colors:
Item #
Putup
Ship Weight
Color
Notes
Item Desc
Revision Number: 1
© 2013 Belden, Inc
All Rights Reserved.
Revision Date: 06-09-2010
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
Page 3 of 4
10-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
3015A Multi-Conductor - 300V Power-Limited Tray Cable
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Page 4 of 4
10-30-2013