87190602000

Description
Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT
CategoryThe connector    Connector bracket   
File Size95KB,3 Pages
ManufacturerBELDEN
Environmental Compliance
Download Datasheet Parametric Compare View All

87190602000 Overview

Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT

87190602000 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerBELDEN
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Is SamacsysN
CertificationCE; CEC; CUL; NEC; UL
conductor materialTINNED COPPER
Connector bracket typeWIRE AND CABLE
structureSTRANDED
diameter7.95 mm
insulator materialPE
Jacket materialPOLYVINYL CHLORIDE
length609.6 mm
Number of conductors2
Maximum operating temperature80 °C
Minimum operating temperature-20 °C
Rated current7 A
Rated voltage600 V
resistance0.015 Ω
shieldYES
stay19X29
Wire gauge16 AWG
Wire and Cable NamesCOMMUNICATION CABLE
Base Number Matches1
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
8719 Multi-Conductor - Single-Pair Cable
For more Information
please call
1-800-Belden1
General Description:
16 AWG stranded (19x29) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil® shield
(100% coverage), 18 AWG stranded TC drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
1
16
19x29
TC - Tinned Copper
2
Total Number of Conductors:
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PE - Polyethylene
.032
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
18
Stranded
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride .032
Overall Cable
Overall Nominal Diameter:
0.313 in.
Pair
Pair Color Code Chart:
Number Color
1
Black & Clear
Pair Lay Length & Direction:
Lay Length (in.) Twists (twist/ft) Direction
2.750
4.400
Left Hand
Mechanical Characteristics (Overall)
Operating Temperature Range:
UL Temperature Rating:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius/Minor Axis:
-20°C To +80°C
80°C (UL AWM Style 20253)
44 lbs/1000 ft.
102 lbs.
3.250 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
NEC Articles:
CEC/C(UL) Specification:
AWM Specification:
EU Directive 2011/65/EU (ROHS II):
EU CE Mark:
CL2, CM
800, 725
CM
UL Style 20253 (600 V 80°C)
Yes
Yes
Page 1 of 3
01-09-2015

87190602000 Related Products

87190602000 87190601000 871906010000 8719060U500 8719060500 8719060U1000 87190605000
Description Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT Wire And Cable, 2 Conductor(s), 16AWG, 600V, Communication Cable, ROHS COMPLIANT
Is it Rohs certified? conform to conform to conform to conform to conform to conform to conform to
package instruction ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT ROHS COMPLIANT
Reach Compliance Code compliant compliant compliant compliant compliant compliant compliant
Certification CE; CEC; CUL; NEC; UL CE; CEC; CUL; NEC; UL CE; CEC; CUL; NEC; UL CE; CEC; CUL; NEC; UL CE; CEC; CUL; NEC; UL CE; CEC; CUL; NEC; UL CE; CEC; CUL; NEC; UL
conductor material TINNED COPPER TINNED COPPER TINNED COPPER TINNED COPPER TINNED COPPER TINNED COPPER TINNED COPPER
Connector bracket type WIRE AND CABLE WIRE AND CABLE WIRE AND CABLE WIRE AND CABLE WIRE AND CABLE WIRE AND CABLE WIRE AND CABLE
structure STRANDED STRANDED STRANDED STRANDED STRANDED STRANDED STRANDED
diameter 7.95 mm 7.95 mm 7.95 mm 7.95 mm 7.95 mm 7.95 mm 7.95 mm
insulator material PE PE PE PE PE PE PE
Jacket material POLYVINYL CHLORIDE POLYVINYL CHLORIDE POLYVINYL CHLORIDE POLYVINYL CHLORIDE POLYVINYL CHLORIDE POLYVINYL CHLORIDE POLYVINYL CHLORIDE
length 609.6 mm 304.8 mm 3048 mm 152.4 mm 152.4 mm 304.8 mm 1524 mm
Number of conductors 2 2 2 2 2 2 2
Maximum operating temperature 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C 80 °C
Minimum operating temperature -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
Rated current 7 A 7 A 7 A 7 A 7 A 7 A 7 A
Rated voltage 600 V 600 V 600 V 600 V 600 V 600 V 600 V
resistance 0.015 Ω 0.015 Ω 0.015 Ω 0.015 Ω 0.015 Ω 0.015 Ω 0.015 Ω
shield YES YES YES YES YES YES YES
stay 19X29 19X29 19X29 19X29 19X29 19X29 19X29
Wire gauge 16 AWG 16 AWG 16 AWG 16 AWG 16 AWG 16 AWG 16 AWG
Wire and Cable Names COMMUNICATION CABLE COMMUNICATION CABLE COMMUNICATION CABLE COMMUNICATION CABLE COMMUNICATION CABLE COMMUNICATION CABLE COMMUNICATION CABLE
Base Number Matches 1 1 1 1 1 1 1
Maker BELDEN - - BELDEN BELDEN BELDEN BELDEN
Is Samacsys N - - N N N N
Mobile Terminal Antenna Design Techniques
The performance of antennas, including those for mobile terminals, is closely related to their size. When discussing antennas, the standardized electrical length, which is based on the frequency wavel...
JasonYoo RF/Wirelessly
The menu and playback interface are covered under evc
There is a realplay player under evc. When you click the view menu, its menu will be covered by the video being played. Now I want to know if I can pause the video when clicking this menu, because whe...
8573420 Embedded System
UV sensor
I would like to ask, I want to detect ultraviolet rays with a wavelength of 180nm-260nm, but now all the ones I have found are for 220V voltage. I want a UV sensor with DC power supply. I wonder which...
旻彧 Sensor
Intelligent home weak current wiring standard specification (must read for decoration)
1. General AV wiring issues that need to be noted: 1. Component lines can be made of three ordinary video cables plus an audio cable. Generally, the signal transmission is attenuated within 5 meters; ...
xyh_521 Industrial Control Electronics
eDMA advanced skills: Introduction to scatter/gather usage
[align=center] [align=left]Official information: [/align] [/align][align=left]This time I would like to share with you an experience sharing from abroad. The author uses KDS and FRDM-K64F development ...
wingard NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1131  275  2323  1161  2627  23  6  47  24  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号