EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MR.2A5.25.25

Description
Mains Power Connector, 2.5A, 250V, Male, Solder Terminal, Plug
CategoryThe connector    The connector   
File Size704KB,2 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.MR.2A5.25.25 Overview

Mains Power Connector, 2.5A, 250V, Male, Solder Terminal, Plug

F.MR.2A5.25.25 Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
Reach Compliance Codeunknown
ECCN codeEAR99
Is SamacsysN
Other featuresSTANDARD: IEC/EN 60320; VDE, CSA, FASTON
Body/casing typePLUG
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2.5A, 250V
Manufacturer's serial numberF.MR
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialMETAL
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
IEC Inlet Filters
F.MH-F.MK-F.ML-F.MM-F.MP-F.MQ-F.MR-F.MS
series
With fuse holder, bipolar switch and voltage selector
This series gives a high level of suppression within a compact
enclosure. The IEC 60320 inlet power entry module combines 1 or 2
fuse holders for US and IEC fuses, with a bipolar rocker switch, earth
choke and input voltage selector.
Designed for use in business, consumer, test and medical equipment
for international markets.
Current ratings from 1A to 6A
Comprehensive range of filter performance options
Integral single or twin fuse holder
Optional voltage selector
Optional earth line choke
Horizontal or vertical mounting
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
fuse holder for 1 fuse (F.MH. - F.ML. - F.MP. - F.MR)
or 2 fuses (F.MK. - F.MM. - F.MQ. - F.MS)
5 x 20mm (IEC) or 6.3 x 32mm (US),
bipolar rocker switch,
voltage selector 110/220Vac (F.MH - F.MK - F.ML
- F.MM only); internal components sealed with
self-extinguishing resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.8mm (OUTPUT);
ground terminal connected to case.
Mounting:
F.MH, F.MK, FML, FMM versions now available in
vertical mounting version - (F.**.***.**.**.010) with
no approvals.
Filter Range
(example pt no. - F.MH.01A.20.25)
Code
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
20.- -
01A 24.- -
30.- -
34.- -
21.- -
2A5 25.- -
31.- -
35.- -
22.- -
04A 26.- -
32.- -
36.- -
23.- -
06A 27.- -
33.- -
37.- -
I
R
L
1
(A) (mH)
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
2 x 10
1
2 x 10
2 x 22
2 x 22
2x2
2.5 2 x 2
2x8
2x8
2x1
4
2x1
2x8
2x8
2x1
6
2x1
2 x 2.5
2 x 2.5
L
2
Cx
1
(mH) (µF)
0.22
Cx
2
(µF)
0.1
Cy
(pF)
2 x 4700
2 x 4700
2 x 4700
F.MH.
F.MK.
F.MQ.
F.MS.
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.22
0.1
2 x 4700
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
Climatic category:
Bipolar rocker
Switches:
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
HPF (25/085/21);
Temperature range: -25°C to +85°C
10(4)A / 250Vac (Rated current),
50000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Voltage selector:
110-220Vac (F.MH - F.MK - F.ML - F.MM only).
Leakage current (I
L
):
at 220V, 50Hz, max value
F.ML.
F.MM.
F.MP.
F.MR.
0.65 0.22
2 x 4700
0.1
2 x 4700
0.65 0.22
2 x 4700
0.1
2 x 4700
2 x 0.003
0.65 0.22
l
L
(mA)
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
2 x 0.003
2 x 0.43
R
(M
Ω
)
0.33
0.33
0.33
0.33
0.33
0.33
0.33
0.33
No approvals, Circuit Diagram D
No approvals, Circuit Diagram C
Not applicable to FMP,FMR
Approvals
32
.010 = Vertical mounting option (addition to standard pt no.)
25 = Rocker switch
26 = Illuminated rocker switch
Circuit Diagram:
H = 1 fuse
A
K = 2 fuses
L = 1 fuse + earth choke
B
M = 2 fuses + earth choke
P = 1 fuse, single pole switch (no voltage selector)
D
Q = 2 fuses, single pole switch (no voltage selector)
R = 1 fuse, double pole switch (no voltage selector)
C
S = 2 fuses, double pole switch (no voltage selector)
I customized a new platform in pb5.0. In "New Connection", "Direct Connection" is grayed out and cannot be selected. Which component is missing?
I searched online for a while and someone said to add Feature: Communication Services and Networking -> Networking - Wide Area Network[WAN](Select all). After adding it, other options in "New Connecti...
dai_weis Embedded System
2009 Jiangxi Province Electronics Competition Jinggangshan University Award-winning Paper
[i=s] This post was last edited by paulhyde on 2014-9-15 09:05 [/i] 2009 Jiangxi Province Electronics Competition Jinggangshan University Award-winning Paper...
aonier Electronics Design Contest
Shengbangwei's lithium battery management chip and high current op amp
I was just chatting casually with Yanyan, and she said, "I saw a lot of tears under a post you posted. Hahahaha, hahaha, it makes me sad to see you like that." Then we chatted for a while. Actually, f...
辛昕 Domestic Chip Exchange
Question about inductor
In a circuit, when a DC power supply is charging an inductor, can the inductor also be understood as a reservoir? As shown in the figure below. Does this reservoir store all the electrons? And does it...
secondlife110 Analog electronics
Altium Designer 20 released
I haven’t used AD19 yet, but today I found out that AD20 is also out....
dcexpert PCB Design
Interface technology question, please answer
As shown in the figure below[[i]This post was last edited by yukilovelove on 2011-4-26 15:39[/i]]...
yukilovelove Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1637  2877  272  1803  1395  33  58  6  37  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号