EEWORLDEEWORLDEEWORLD

Part Number

Search

88953-N116LF

Description
Board Connector, 96 Contact(s), 4 Row(s), Male, Straight, 0.079 inch Pitch, Solder Terminal, Locking, Natural Insulator, LEAD FREE
CategoryThe connector    The connector   
File Size1MB,8 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

88953-N116LF Overview

Board Connector, 96 Contact(s), 4 Row(s), Male, Straight, 0.079 inch Pitch, Solder Terminal, Locking, Natural Insulator, LEAD FREE

88953-N116LF Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAmphenol
package instructionLEAD FREE
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Board mount optionsPEG
body width0.622 inch
subject depth0.669 inch
body length1.887 inch
Connector typeBOARD CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedTin (Sn)
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact resistance10 mΩ
Contact styleSQ PIN-SKT
DIN complianceNO
Durability250 Cycles
Filter functionNO
IEC complianceNO
maximum insertion force.4448 N
Insulation resistance1000000000 Ω
Insulator colorNATURAL
insulator materialGLASS FILLED LIQUID CRYSTAL POLYMER
JESD-609 codee3
MIL complianceNO
Manufacturer's serial number88953
Plug contact pitch0.079 inch
Match contact row spacing0.079 inch
Mixed contactsNO
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number4
Number of rows loaded4
Maximum operating temperature105 °C
Minimum operating temperature-55 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
PCB contact row spacing2.0066 mm
polarization keyPOLARIZED HOUSING
Rated current (signal)1 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal pitch2 mm
Termination typeSOLDER
Total number of contacts96
UL Flammability Code94V-0
Evacuation force-minimum value.1946 N
Base Number Matches1
1
2
3
4
PRODUCT NUMBER
88953-XYY
88953-XYYLF
2.00 REF
1.40 REF
POS.1
24
46.00 REF
2.30 REF
0.50 REF
D
17.00 REF
3.45 REF
6.00 REF
C
B
A
15.80 REF
11.50 REF
2.00 RF
CONTACT AREA
2.00 REF
47.93 REF
DIM A 0.1
DIM B REF
PLATING IN CONTACT AREA
A
DASH NUMBER
-N1YY
-1YY
-2YY
-3YY
-5YY
-N1YYLF
-1YYLF
-2YYLF
-5YYLF
PERFORMANCE LEVEL
TELCORDIA CO (NXT)
TELCORDIA CO
TELECOM CLASS
IEC CLASS 1
TELCORDIA UE
TELCORDIA CO (NXT)
IEC CLASS 1
TELCORDIA CO
IEC CLASS 1
TELECOM CLASS
TELCORDIA UE
NOTES
A
-
-
-
-
-
SEE NOTE 9
SEE NOTE 9
SEE NOTE 9
SEE NOTE 9
CONFIDENTIAL and PROPRIETARY information of FCI.
This document is the property of and embodies
to others without the written consent of FCI.
document may be used in any way or disclosed
No part of the information shown on this
mat'l code
--
ecn no.
dr
date
tolerances unless
otherwise specified
CUSTOMER
COPY
projection
title
www.fciconnect.com
ltr
0.X
0.XX
.XXX
angles
dr
engr
chr
appd
0.3
0.13
.051
2
linear
U V06-0569 DCH2006-06-13
V
-
Copyright FCI.
DG09-0256
-
TER 2009-08-19
-
-
0
METRAL SIGNAL HEADER
4 MOD, 4 ROW STB
METRAL
code
dwg no
P
R
S
T
V03-1059 DAI
V05-0385 DAI
V05-0796 DAI
V06-0123 DAI
revision
sheet
09/24/03
04/22/05
08/19/05
02/09/06
V
1
V
2
Pro/E
T.BRUNGARD
M.STRAWSER
M.STRAWSER
M.STRAWSER
11/19/99
11/19/99
11/19/99
02/29/00
scale
MM
product family
size
2:1
V
8
3
A
88953
cage code
213
sheet
1 of 8
B
4
sheet
V
3
V
4
V
5
V
6
V
7
B
1
REV E - 2006-04-18
index
2
22526
PDM: Rev:V
STATUS:
Released
Printed: Nov 30, 2009
.
Uncover the mystery of MOS tube damage! What other reasons do you know?
Mos switch principle (brief): MOS is a voltage-driven device. As long as an appropriate voltage is applied between the gate and the source, a path between the source and the drain is formed. The resis...
eric_wang Power technology
Lumen Study Notes Part 2: A Thorough Study of the Lumen Library
Originally I wanted to get some hardware this time, but my CD kept going back and forth between my workplace and home, and I couldn’t find it at home. I put it in the CD-ROM drive at work. I’ll talk a...
ddllxxrr Microcontroller MCU
How to put a folder (with several files in it) on the desktop?
Under platform.bib, add a file, and it will be found by default under Windows after the system starts. If I want to put a folder on the desktop with several files in it, after the system starts, the a...
040434 Embedded System
Embedded Problems
Hello everyone, I am a college student and I have to choose a major this semester. I would like to ask, if I just started to learn embedded system, do I need a lot of hardware knowledge? Thank you....
fall1979 Embedded System
Note: Create a professional image before the interview!
1. How to be a well-dressed man When applying for a job, it is best for boys to wear a suit and leather shoes, a stiff collar shirt, and a crisp tie to look chic and handsome. To be a successful man, ...
ESD技术咨询 Talking about work
Analysis of Long Tail Differential Amplifier Circuit
Long-tail differential amplifier circuit differential mode input circuit diagramDifferential mode input and output waveforms of long-tail differential amplifier circuitLong-tail differential amplifier...
eeboyok Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1589  1854  1277  2124  2680  32  38  26  43  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号