MKS3P110VDC

Description
Power/Signal Relay, 3PDT, Momentary, 0.012A (Coil), 110VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    relay   
File Size2MB,9 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

MKS3P110VDC Overview

Power/Signal Relay, 3PDT, Momentary, 0.012A (Coil), 110VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT

MKS3P110VDC Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
body width34.5 mm
body height52.5 mm
Body length or diameter34.5 mm
Maximum coil current (DC)0.012 A
Coil operating voltage (DC)88 V
Coil power1400 mW
Coil release voltage (DC)16.5 V
Coil resistance8960 Ω
Maximum coil voltage (DC)110 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@30VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)30 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Installation featuresSOCKET MOUNT
operating hours30 ms
Maximum operating temperature60 °C
Minimum operating temperature-40 °C
physical size34.5mm x 34.5mm x 52.5mm
GuidelineCE; IEC; TUV; UL
Relay actionMOMENTARY
Relay function3PDT
Relay typePOWER/SIGNAL RELAY
release time20 ms
surface mountNO
Termination typeSNAP-ON
General-purpose Relays
MK-S
(New Models)
CSM_MK-S_DS_E_6_1
New Super MK Relays.
Models with Latching Lever Added to
the Series.
• Same mounting and internal wiring as the previous Super
MK Relays
• Built-in mechanical indicator enables checking contact
operation.
• Two modes can be used to check circuits for models with
latching lever.
• Nameplate provided on models with latching lever.
• All materials are RoHS compliant.
• UL and IEC (TÜV) certification.
Features
Models with Latching Lever
Operation indicator
*
Nameplate
Mechanical indicator
Latching lever
DC: Blue
AC: Red
Yellow
button
Operating Method for Latching Lever
Relay in
Normal Operation
For Momentary
Operation
For Lock
Operation
*
The operation indicator is built in only on specified models.
Example of Applications of Models with Latching
Levers
Operation checks in relay sequence circuits
Model Number Structure
Model Number Legend
MKS@@@@@-@-@
1 2 3 4 5
1. Contact Form
2: DPDT
3: 3PDT
2. Terminals
P: Plug-in
3. Mechanical Indicator/Test Button
Blank: Mechanical indicator
I:
Mechanical indicator and lockable test button
4. LED Indicator
Blank: Standard
N:
LED indicator
Slide the latching lever
to the first position,
then press the yellow
button with
an
insulated tool to
operate the contact.
Slide the latching
lever to the second
position.
(The contact is now in
the locked position.)
6
7
5. Coil Polarity
Blank: Standard
1:
Reverse polarity (DC coil only)
6. Surge Absorption
Blank: Standard
D:
Surge absorber diode (DC coil only)
V:
Surge absorber varistor (AC coil only)
7. Internal Connections
Blank: Standard
2 or 5: Non-standard connections (Refer to
“Terminal
Arrangement and Internal Connection (Bottom View)”.)
8. Rated Voltage
(Refer to
“Coil Ratings”.)
1
Migrating Software Projects from StellarisWare to TivaWare
Migrating Software Projects from StellarisWare to TivaWare...
蓝雨夜 Microcontroller MCU
【bk7231N】Exploration of Tuya products in SPI and other communication aspects
After doing a lot of embedded systems, I instinctively consider the richness of a chip's peripherals, so I want to investigate the peripheral performance of the Tuya chip in my hand. So I proposed a t...
javnson RF/Wirelessly
RTDX Application Debugging
RTDX tests DSP Target to transfer data to PC: a) Create a project, edit the source code (.c/.asm), add header files (.h), library files (.lib) and link command files (.cmd) b) Add and modify the RTDX ...
Aguilera DSP and ARM Processors
TI adds four new automotive-qualified 32-bit digital signal controllers
Recently, Texas Instruments (TI) announced that its TMS320F280xx digital signal controller family for motor control, digital power conversion and intelligent sensor control applications has added four...
frozenviolet Energy Infrastructure?
A simple version of Snake written in Python
[code]__author__ = 'ChenYan'from tkinter import * import threading import queue import time import randomclass GUI(Tk):'''class GUI use to create the gui'''def __init__(self, queue):Tk.__init__(self)s...
chenyan2010521 Programming Basics
choride 20kva UPS serial port problem
I am currently working on a remote monitoring of a CHORIDE 20KVA UPS, which is a 1997 model. I send commands to the UPS according to the manufacturer's agreement, but it does not respond. The interfac...
zhzhiqiang Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1391  1093  547  91  69  29  23  11  2  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号