EEWORLDEEWORLDEEWORLD

Part Number

Search

SP00P-10-98PW(025)

Description
MIL Series Connector
CategoryThe connector    The connector   
File Size225KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

SP00P-10-98PW(025) Overview

MIL Series Connector

SP00P-10-98PW(025) Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
Connector typeMIL SERIES CONNECTOR
Manufacturer's serial numberSP00P
Base Number Matches1
PT00 (MS3110)
SP00
wall mounting receptacle
(TP)
S
R
PT
.120 ± .005 Dia.
(.147 ± .005 Dia., size 24)
SP
.150 ± .005 Dia.
(TP)
M
L
Q
R S
4 Holes
A
“PG” Cable Gland Seal
K
“A” General Duty/
“C” Pressurized“
“A” (SR), “E” (SR), “P” (SR),
MS / “F” Strain Relief
Z
“P” Potting Boot
L
TERMINATION ASSEMBLIES
“E” Open Wire Seal
L
V
L
L
L
N
D
PT00PG-XX-XXX
N
D
N
GDH
N
N
D
“J” Cable Seal
.375 MIN
PT00A-XX-XXX
SP00A-XX-XXX
PT00C-XX-XXX
C
PT00E-XX-XXX
SP00E-XX-XXX
MS3110E-XX-XXX
PT00P-XX-XXX
SP00P-XX-XXX
MS3110P-XX-XXX
RELEASED / Dec . 21 2015, 2:09:12 PM
XL
PT00A-XX-XXX (SR)
SP00A-XX-XXX (SR)
PT00E-XX-XXX (SR)
SP00E-XX-XXX (SR)
PT00P-XX-XXX (SR)
SP00P-XX-XXX (SR)
MS3110F-XX-XXX
To complete part number see how to order on page 25.
n
(MMC) located within .0025 of (TP)
Receptacle Front View
R
S
(TP)
Max.
PT
SP
PT
SP
A
+.001
–.005
K +.020
–.010
PT
SP
P
N
D
MS3110J-XX-XXX
Receptacle Side View
M +.010
Q
–.000
L
Thread
Max.
PT
SP
Class 2A
Class “A”, “C”
D
Min.
L
Max.
N
Max.
V
Thread
Class A
Shell
Size
6
8
10
12
14
16
18
20
22
24
.469
.594
.719
.812
.906
.969
1.062
1.156
1.250
1.375
.641
.734
.812
.938
1.031
1.125
1.203
1.297
1.375
1.500
.688
.812
.938
1.031
1.125
1.219
1.312
1.438
1.562
1.688
.953
1.047
1.125
1.250
1.344
1.438
1.516
1.672
1.750
1.875
H
Max.
.348
.473
.590
.750
.875
1.000
1.125
1.250
1.375
1.500
L
Max.
.493
.493
.493
.493
.493
.493
.493
.650
.650
.683
.524 .906
.524 .906
.524 .906
.524 .906
.524 .906
.524 .906
.524 .906
.650 1.125
.650 1.125
.683 1.188
L
Max.
.431
.431
.431
.431
.431
.431
.431
.556
.556
.589
.462
.462
.462
.462
.462
.462
.462
.556
.556
.589
.3125-32 NEF
.4375-28 UNEF
.5625-24 NEF
.6875-24 NEF
.8125-20 UNEF
.9375-20 UNEF
1.0625-18 NEF
1.1875-18 NEF
1.3125-18 NEF
1.4375-18 NEF
L
Max.
N
Max.
.468
.468
.468
.468
.468
.468
.531
.531
.531
.498
Z
Max.
PT
SP
.438 .175 1.553 .462
.438 .297 1.553 .590
.438 .421 1.553 .717
.438 .546 1.553 .834
.438 .663 1.553 .970
.438 .787 1.553 1.088
.438 .879 1.553 1.216
.531 1.014 1.703 1.332
.531 1.134 1.703 1.460
.498 1.259 1.765 1.585
XL
Max.
.3750-32 NEF
.5000-28 UNEF
.6250-24 NEF
.7500-20 UNEF
.8750-20 UNEF
1.0000-20 UNEF
1.1875-18 NEF
1.1875-18 NEF
1.4375-18 NEF
1.4375-18 NEF
Class “PG”
L
Max.
Class “A” (SR), “E” (SR), “P” (SR), MS / “F”
Shell
C
Size Thread
Class “E”, MS / “E”
Class “P”, MS / “P”
6
8
10
12
14
16
18
20
22
24
6-32
6-32
6-32
6-32
6-32
8-32
8-32
8-32
8-32
.240
.302
.428
.552
.615
.740
.740
.928
.990
D
Min.
.125
.188
.312
.375
.500
.625
.625
.750
.800
G
Max.
.812
.875
1.000
1.125
1.188
1.438
1.438
1.625
1.719
1.922
1.922
1.922
1.922
2.047
2.078
2.344
2.344
2.406
.550
.675
.803
.920
1.047
1.165
1.290
1.418
1.543
N
Max.
1.266
1.266
1.266
1.266
1.266
1.266
1.266
1.516
1.516
1.578
.440
.560
.685
.813
.930
1.057
1.175
1.301
1.430
1.555
N
Max.
.192
.317
.434
.548
.673
.798
.899
1.024
1.149
1.274
D
Min.
1.438
1.438
1.438
1.438
1.438
1.438
1.438
1.656
1.656
1.717
.484
.608
.734
.858
.984
1.110
1.234
1.360
1.484
1.610
Class “J”
D
N
Closed Free Max.
.168
.205
.338
.416
.550
.600
.635
.670
.740
.230
.312
.442
.539
.616
.672
.747
.846
.894
.547
.675
.812
.940
1.067
1.194
1.322
1.449
1.576
2.271
2.271
2.411
2.599
2.943
3.172
3.610
3.766
3.985
M12x1.5-6H
M16x1.5-6H
M16x1.5-6H
M18x1.5-6H
M22x1.5-6H
M25x1.5-6H
M25x1.5-6H
M32x1.5-6H
M32x1.5-6H
B
Thread
.936
.936
.936
.936
.936
.936
1.180
1.180
1.180
All dimensions for reference only.
13
Recently read about MPPT information
希望对大家有用...
navigat Power technology
I want to call a function or variable in a BC file in an AC file, but BC does not have a bh file. How do I handle this?
I want to call a function D() and variable E in the BC file in the AC file, but BC does not have a bh file. How to deal with it?...
深圳小花 MCU
Circuit Diagram Recognition 9- Methods of Recognizing Integrated Circuit Diagrams
[align=left][color=rgb(34, 34, 34)][font="]With the continuous development of microelectronics technology, various radio electronic devices are increasingly using integrated circuits, and integrated c...
tiankai001 Integrated technical exchanges
[NUCLEO-L452RE review] + STM32CUBEMX generated program plus printf
Anyone who works with microcontrollers knows that to add printf, you need to redefine fputc. I will write down the steps below, and use them as a mark for similar problems in the future: First, genera...
ddllxxrr stm32/stm8
Multifunctional Handheld Digital Multimeter Disassembly Part 2
[i=s]This post was last edited by Digital Leaf on 2021-10-15 16:57[/i]In the previous article, I have tried the basic functions of this multimeter, and now I can officially disassemble it.This disasse...
数码小叶 Making friends through disassembly
Shenzhen: Support individual consumers to purchase new energy vehicles with a subsidy of up to RMB 10,000 per vehicle
I don’t quite understand why the various online promotions don’t just reduce the fees, but require consumers to apply for them themselves. . .According to online news, Shenzhen has issued several meas...
led2015 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1559  1073  1955  2632  2711  32  22  40  53  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号