EEWORLDEEWORLDEEWORLD

Part Number

Search

BJ457PP

Description
CONNECTOR, PANEL MOUNT, MALE, BNC, TWINAXIAL CONNECTOR, SOLDER, JACK
CategoryThe connector    The connector   
File Size63KB,2 Pages
ManufacturerArtysen Embedded Technologies
Download Datasheet Parametric View All

BJ457PP Overview

CONNECTOR, PANEL MOUNT, MALE, BNC, TWINAXIAL CONNECTOR, SOLDER, JACK

BJ457PP Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
Other featuresSTANDARD: MIL-C-49142, POLARIZED
Body/casing typeJACK
Connector typeRF TWINAXIAL-BNC CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Coupling typeBAYONET
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number450
Installation methodSTRAIGHT
OptionsGENERAL PURPOSE
Panel mountingYES
Termination typeSOLDER
Base Number Matches1
19
Concentric twinax 450 series
Concentric Twinax 450 Series
125°
.080"110°
110°
.080"
125°
125°
.080"
125°
3-lug & 4-lug Keyings
90°
TYP
P
125°
.067"
.062"
TYP
R
125°
.067"
.062"
TYP
W
110°
.067"
.062"
TYP
FL
.067"
.062"
TYP
The 450 Series was designed for airborne digital data bus applications
utilizing the MIL-STD-1553B data bus. The 450 Series will fit most
twinax cables.
Refer to page 20 for photo of intermediate contacts.
Bulkhead Jack
Rear mount, Solder pot
.438 HEX NUT
.438 HEX NUT
.3125-32UNEF-2A
.750
MAX
SOLDER POT ACCEPTS
.026 DIA CONDUCTOR
.240
DIA
Connectors are available in five different coupling configurations
which include 3-lug versions with three (3) separate keyings, a 4-lug,
and a threaded version with safety wire holes.
Diagrams shown above are for plugs.
Key
Code
Intermediate Contact
Pin
Socket
Coupling
Type
3-lug
3-lug
3-lug
4-lug
Mounting
.047 DIA SAFETY
WIRE HOLES
Holes:
2 PLACES
DD8.130
DD8.125 (Threaded)
Threaded
.075
.795
1.03
P
R
W
FL
-
BJ450PP
BJ450RP
BJ450WP
BJ450FLP
BJ3450P
BJ450PS
BJ450RS
BJ450WS
BJ450FLS
BJ3450S
Bulkhead Jack
Front mount, Solder pot
.437 HEX NUT
.047 DIA SAFETY
WIRE HOLES 2 PLACES
.438 HEX NUT
SOLDER POT
ACCEPTS .750
.026 MAX MAX
DIA COND.
Coupling
Type
3-lug
3-lug
3-lug
4-lug
Threaded
Key
Code
Intermediate Contact
Pin
Socket
.240
DIA
Mounting
Holes:
DD8.250
DD8.125 (Threaded)
.456
.795
.075
.3125-32UNEF-2A
1.03
P
R
W
FL
-
BJ457PP
BJ457RP
BJ457WP
BJ457FLP
BJ3457P
BJ457PS
BJ457RS
BJ457WS
BJ457FLS
BJ3457S
BJ457FLP-1 SHOWN
.030
Right Angle Cable Plug
All Crimp
1.46
SEALING
SLEEVE
Coupling
Type
3-lug
3-lug
3-lug
4-lug
Threaded
Key
Code
Intermediate Contact
Pin
Socket
1.10
MAX
;;;;;;;
;;;;;;;
;;;;;;;
(1.25)
.500 DIA
OVER KNURL
PLR455ACPP-201
P
R
W
FL
-
PLR455ACPP-
1
PLR455ACRP-
1
PLR455ACWP-
1
PLR455ACFLP-
1
PLR3455ACP-
1
PLR455ACPS-
1
PLR455ACRS-
1
PLR455ACWS-
1
PLR455ACFLS-
1
PLR3455ACS-
1
RFI Jack Caps & Bulkhead Jack Terminations
For use with 450 Series Plugs
Rear Mount
Coupling
Type
3-lug
3-lug
3-lug
4-lug
Threaded
1
Terminations
RFI Caps
RFI457-
3
RFI457-
3
RFI457-
3
RFI457FL-
3
RFI3457-
3
Intermediate Contact
Pin
Socket
TBJ451P-
3
-R
TBJ451P-
3
-R
TBJ451P-
3
-R
TBJ451FLP-
3
-R
TBJ3451P-
3
-R
3
TBJ451S-
3
-R
TBJ451S-
3
-R
TBJ451S-
3
-R
TBJ451FLS-
3
-R
TBJ3451S-
3
-R
- Refers to Cable Group Table see pages 91-133. "D" mounting holes see page 54
- For Chain options, see page 45.
Trompeter Products Catalog - T21 Military/Aerospace
ISO 9001
Registered
R
(800) 982-2629
Fax: (818) 706-1040
www.trompeter.com
GetProfileInt Issue
void CMyTracker::Construct() { AfxLockGlobals(CRIT_RECTTRACKER); static BOOL bInitialized; if (!bInitialized) { // sanity checks for assumptions we make in the code ASSERT(sizeof(((RECT*)NULL)->left) ...
wlm99111 Embedded System
I am a beginner in microcontrollers and don't quite understand the timer/counter interrupt problem!
I am a beginner of single-chip microcomputers, and I don't quite understand the timer interrupt problem! I don't know if I'm asking the right question! 1. If a program has 3 statements, 1, 2, and 3. I...
fengbingchun Embedded System
place
Good, I like it....
long522637636 Analog electronics
Learning simulation + oscillation
[i=s]This post was last edited by dontium on 2015-1-23 11:42[/i] [url=deyisupport./blog/b/signalchain/archive/2013/01/10/51390.aspx]Why operational amplifiers oscillate - A brief analysis of two commo...
huixianfxt Analogue and Mixed Signal
About COM serial port issues
There are four serial ports on the terminal, the addresses are 3f8, 2f8, 3e8, 2e8. I set the environment variables BSP_SERIAL2, BSP_SERIAL3, BSP_SERIAL4, and changed the serial port addresses to the a...
arthas Embedded System
Calibration Algorithm for AD Sampling Accuracy in DSP TMS320F2812 Programming
[i=s]This post was last edited by Jacktang on 2017-11-24 08:25[/i] The F2812 has an internal integrated ADC conversion module. This module is a 12-bit, pipelined analog-to-digital converter with a bui...
Jacktang DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2429  2547  2051  2105  2929  49  52  42  43  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号