The general purpose Bulletin 800Z Zero-Force Touch Buttons are
designed for use by machine control systems requiring the use of
two hands. An interlinked sensor surface weaves two capacitive
sensors in offset planes for superior product sensitivity.
The 800Z touch buttons are ergonomically designed for ease of
operation. No force is required to operate the switch; simply
touching the surface of the switch will initiate an output. The 800Z
can detect the hand though most industrial gloves.
The contour of the 800Z touch buttons serves two purposes; it
easily conforms to the shape of the hand while helping prevent
defeatability when two-hand control is needed.
Two bi-coloured diagnostic LEDs provide guidance during operation.
The power/fault LED blinks at different rates to provide diagnostic
information to the user. The 800Z detects the presence of a hand
during power-up, noise, and conductive film build-up over time.
Mounting
Cable
Features
•
•
•
•
Zero Force to operate
Ergonomic design
EMC protection
Diagnostic LEDs
Electrical Life
EM-Relay inductive load See Load Life Curves
Vibration
1.5mm (0.06in) 10-55Hz
Shock
100g,11ms half-sine
Load Life Curves for General Purpose Product Line
Relay Output—Maximum DC Load Breaking Capacity
300
200
100
DC Voltage
Relay Output—Electrical Endurance
10
250V AC
10
Resistive Load
Operations
6
50
40
30
20
10
0.1 0.2 0.5
10
5
cosϕ = 1
cosϕ = 0.7
cosϕ = 0.4
1
2
5
10
20
10
4
0
1
2
3
4
5
6
7
8
DC Current (A)
Switching Current (A)
11-2
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Product Selection
Mounting Hole
Size
Input Voltage Range and
Output Type
85...264V AC Input
Relay Output
Catalogue Number
Guard
6ft Cabled—5-Wire
5-Pin Mini QD
800Z-GF3Q5
800Z-GF3Q5B
800Z-GL3Q5
800Z-GL3Q5B
800Z-GF2Q5
800Z-GF2Q5B
800Z-GL2Q5
800Z-GL2Q5B
889D-F5AC-2
5-Pin Micro QD
800Z-GF3065
No Guard
800Z-GF3065B
Black Guard
30.5 mm
Mounting Hole
800Z-GL3065
No Guard
10...40V DC and 20...30V AC Input
Relay Output
800Z-GL3065B
Black Guard
800Z-GF2065
No Guard
85...264V AC Input
Relay Output
800Z-GF2065B
Black Guard
22.5 mm
Mounting Hole
800Z-GL2065
No Guard
10...40V DC and 20...30V AC Input
Relay Output
800Z-GL2065B
Black Guard
Recommended standard cordset, 2m (6.5ft). See pages 15-12 and 15-10 for additional lengths..
889N-F5AE-6F
Use the configurator below to build an 800Z touch button to suit your application.
800Z – G
a
Input Voltage and Output Type
Code
Description
Relay Output
Input: 10...40V DC and 20...30V AC
Output: Relay
Input: 85...264V AC Output: Relay
Transistor Output
10...30V DC; NPN (Sinking) Output
10...30V DC; PNP (Sourcing) Output
L
a
3
b
c
065
c
B
d
-
e
d
Guard Option
Code
Blank
B
Y
Description
No Guard
Black Guard
Yellow Guard
Electrical Connection
Code
Q4
064
124
244
Q5
065
125
245
Description
Sinking/Sourcing Output
➊
4-Pin QD
6 ft (1.8 m) Cabled
12 ft (3.6 m) Cabled
24 ft (7.2 m) Cabled
Relay Output
➋
5-Pin QD
1.8m (6ft) Cabled
3.6m (12ft) Cabled
7.2m (24ft) Cabled
Code
Blank
K1
K2
K3
L
F
N
P
e
Kit Option
➌
Description
No Kit
24V AC/DC Relay Kit
120V AC Relay Kit
240V AC Relay Kit
b
Mounting Hole Size
Code
2
3
Description
22.5mm (0.88in)
30.5mm (1.20in)
➊
These devices are transistor outputs.
➋
These devices have separate N.O. and N.C. output relays with a shared common.
➌
Safety relays should be used in two-hand control applications. Kits not available for solid-state (transistor output) devices. Kits include two identical touch buttons and one
MSR125HP safety relay with removeable terminals.
11-3
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Accessories
Description
Colour
Catalogue
Number
800Z-G3AG1
Yellow
These guards prevent accidental activation of the touch
button surface and protect it from damage. Can be used for
both the 22.5mm and 30.5mm mounting products.
Black
800Z-G3AG2
Guards
Mounting Ring Nut for 22.5mm holes.
Used on 22.5mm devices.
Plastic
800Z-G2AH1
Plastic Mounting Kit
Mounting Ring Nut for 30.5mm holes.
Used on 30.5mm devices.
Plastic
800Z-G3AH1
Plastic Mounting Kit
57mm (2.25in)
Extension
60-2681
30.5mm Swivel/Tilt Mounting Assembly
This bracket allows you to orient the touch button in any
position. It can be mounted on any vertical or horizontal
surface. Compatible with 30.5mm mounting only.
29mm (1.15in)
Extension
60-2439
Swivel Assembly
Shiny Metal
30.5mm to 22.5mm Hole Size Adaptor
This adaptor allows a 22.5mm push button operator to be
installed in a panel with existing 30.5mm mounting holes.
Black Metal
800E-AHA1
800E-AHA2
Adaptor
11-4
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Approximate Dimensions—mm (inches)
40.9
(1.61)
48.3
(1.90)
22mm
Version
Micro Quick
Disconnect
56.9
(2.24)
129.3 (5.09)
35.1
(1.38)
69.9 (2.75)
40.9
(1.61)
30mm
Version
Mini Quick
Disconnect
22mm
Version
Cable
40.9
(1.61)
22.4
(0.88)
129.3 (5.09)
110.3
(4.34)
39.4
(1.55)
General Purpose with Guards
40.9
(1.61)
30mm
Version
Cable
22.4
(0.88)
General Purpose
Typical Wiring Diagram
Electrical Connections: 10...40V DC and 20...30V AC Input Voltage (Relay Output); 85...264V AC Input Voltage (Relay Output)
Note:
Separate N.O. and N.C. output relays with shared common.
Brown (+) L1
Blue (-) L2
Black (N.O.)
White (N.C.)
Gray (Common)
5 Conductor Cabled (Relay Output) for 800Z-GL_ _ _
Electrical Connections: 10...30V DC Input Voltage (Transistor Output); 150mA max. per circuit output
(+)
(-)
(+)
(-)
Brown (+) Blue (-)
Load Black (N.O.)
White (N.C.)
Load
Brown (+) Blue (-)
Black (N.O.) Load
White (N.C.)
Load
4 Conductor Cabled Sinking (NPN)
4 Conductor Cabled Sourcing (NPN)
Applications Details
LED Blink Rate
** ** **
*** *** ***
**** **** ****
Diagnostic
Power Up
Noise Detection
Margin Detection
Description
Device touched during power-up. Device will resume 10 seconds after removal of hand.
Device detected an unacceptable level of noise (>20V/m). Device will resume once noise
subsides.
A conductive film is building up on the sensing surface. Device will resume once cleared.
[font=微软雅黑][color=#434343] [/color][color=#8b0000] [size=5]EEWORLD Forum WeChat public account is officially launched today! Scan the QR code below to join. [/size][/color] [backcolor=rgb(251, 255, 24...
Introduction: We know that when the characteristic impedance of the line is discontinuous, the signal will be reflected through the discontinuous point, causing the signal to overshoot and ring. When...
[i=s]This post was last edited by RF-刘海石 on 2017-8-9 19:34[/i] [size=5][color=#ff0000]First of all, when I guessed the question a few days ago, I said that there would definitely not be amplifiers lik...
I want to learn about the memory management of the ecos operating system recently. I feel lost when reading the source code. For the fixed-size memory block management, I only see the definition of th...
With the promotion of the construction of intelligent communities in the country, anti-theft systems have become essential equipment for intelligent communities. Especially in recent years, the urg...[Details]
5. Identifiers and keywords of C language
A complete PIC microcontroller C language program usually consists of six parts: include files (i.e. header files 1, variable definitions, variable de...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
1 Introduction
Building Automation System (BAS) is a distributed monitoring system (DCS) designed according to distributed information and control theory. It is the result of the mutual de...[Details]
1 Introduction
With the development of control, computer, communication, network technology, etc., a new control technology, namely fieldbus, has emerged in the field of industrial control...[Details]
We know that the inverter consists of two parts: the main circuit and the control circuit. Due to the nonlinearity of the main circuit (switching action), the inverter itself is a source of harmoni...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
Abstract: In recent years, with the establishment and grid-connected power generation of a large number of solar photovoltaic power stations at home and abroad, photovoltaic grid-connected inverter...[Details]
Temperature compensated quartz crystal oscillator (TCXO) is widely used as a high-precision frequency source in communication systems, radar navigation systems, precision measurement and control sy...[Details]
The future energy storage hotspot is not coal or iron ore, but lithium. This lightest metal in nature may be the heaviest resource in the future energy landscape. China launched an ambitious electr...[Details]
Measurement compatibility
It is very important to ensure the compatibility between the pressure sensor and its actual application. Before making a pressure sensor selection, the fo...[Details]
Introduction
my country's rapid economic growth is mainly due to the development of manufacturing and the acceleration of urbanization. However, urbanization cannot be achieved at the expense ...[Details]
At present,
the control system used in
automobiles
can be divided into three parts from the functional point of view:
sensor
unit, control unit and execution unit. Among them,
th...[Details]
Today's automotive application developers face numerous design challenges as modern cars add more electronic functionality, while the need for lower power consumption and smaller printed circuit bo...[Details]