The general purpose Bulletin 800Z Zero-Force Touch Buttons are
designed for use by machine control systems requiring the use of
two hands. An interlinked sensor surface weaves two capacitive
sensors in offset planes for superior product sensitivity.
The 800Z touch buttons are ergonomically designed for ease of
operation. No force is required to operate the switch; simply
touching the surface of the switch will initiate an output. The 800Z
can detect the hand though most industrial gloves.
The contour of the 800Z touch buttons serves two purposes; it
easily conforms to the shape of the hand while helping prevent
defeatability when two-hand control is needed.
Two bi-coloured diagnostic LEDs provide guidance during operation.
The power/fault LED blinks at different rates to provide diagnostic
information to the user. The 800Z detects the presence of a hand
during power-up, noise, and conductive film build-up over time.
Mounting
Cable
Features
•
•
•
•
Zero Force to operate
Ergonomic design
EMC protection
Diagnostic LEDs
Electrical Life
EM-Relay inductive load See Load Life Curves
Vibration
1.5mm (0.06in) 10-55Hz
Shock
100g,11ms half-sine
Load Life Curves for General Purpose Product Line
Relay Output—Maximum DC Load Breaking Capacity
300
200
100
DC Voltage
Relay Output—Electrical Endurance
10
250V AC
10
Resistive Load
Operations
6
50
40
30
20
10
0.1 0.2 0.5
10
5
cosϕ = 1
cosϕ = 0.7
cosϕ = 0.4
1
2
5
10
20
10
4
0
1
2
3
4
5
6
7
8
DC Current (A)
Switching Current (A)
11-2
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Product Selection
Mounting Hole
Size
Input Voltage Range and
Output Type
85...264V AC Input
Relay Output
Catalogue Number
Guard
6ft Cabled—5-Wire
5-Pin Mini QD
800Z-GF3Q5
800Z-GF3Q5B
800Z-GL3Q5
800Z-GL3Q5B
800Z-GF2Q5
800Z-GF2Q5B
800Z-GL2Q5
800Z-GL2Q5B
889D-F5AC-2
5-Pin Micro QD
800Z-GF3065
No Guard
800Z-GF3065B
Black Guard
30.5 mm
Mounting Hole
800Z-GL3065
No Guard
10...40V DC and 20...30V AC Input
Relay Output
800Z-GL3065B
Black Guard
800Z-GF2065
No Guard
85...264V AC Input
Relay Output
800Z-GF2065B
Black Guard
22.5 mm
Mounting Hole
800Z-GL2065
No Guard
10...40V DC and 20...30V AC Input
Relay Output
800Z-GL2065B
Black Guard
Recommended standard cordset, 2m (6.5ft). See pages 15-12 and 15-10 for additional lengths..
889N-F5AE-6F
Use the configurator below to build an 800Z touch button to suit your application.
800Z – G
a
Input Voltage and Output Type
Code
Description
Relay Output
Input: 10...40V DC and 20...30V AC
Output: Relay
Input: 85...264V AC Output: Relay
Transistor Output
10...30V DC; NPN (Sinking) Output
10...30V DC; PNP (Sourcing) Output
L
a
3
b
c
065
c
B
d
-
e
d
Guard Option
Code
Blank
B
Y
Description
No Guard
Black Guard
Yellow Guard
Electrical Connection
Code
Q4
064
124
244
Q5
065
125
245
Description
Sinking/Sourcing Output
➊
4-Pin QD
6 ft (1.8 m) Cabled
12 ft (3.6 m) Cabled
24 ft (7.2 m) Cabled
Relay Output
➋
5-Pin QD
1.8m (6ft) Cabled
3.6m (12ft) Cabled
7.2m (24ft) Cabled
Code
Blank
K1
K2
K3
L
F
N
P
e
Kit Option
➌
Description
No Kit
24V AC/DC Relay Kit
120V AC Relay Kit
240V AC Relay Kit
b
Mounting Hole Size
Code
2
3
Description
22.5mm (0.88in)
30.5mm (1.20in)
➊
These devices are transistor outputs.
➋
These devices have separate N.O. and N.C. output relays with a shared common.
➌
Safety relays should be used in two-hand control applications. Kits not available for solid-state (transistor output) devices. Kits include two identical touch buttons and one
MSR125HP safety relay with removeable terminals.
11-3
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Accessories
Description
Colour
Catalogue
Number
800Z-G3AG1
Yellow
These guards prevent accidental activation of the touch
button surface and protect it from damage. Can be used for
both the 22.5mm and 30.5mm mounting products.
Black
800Z-G3AG2
Guards
Mounting Ring Nut for 22.5mm holes.
Used on 22.5mm devices.
Plastic
800Z-G2AH1
Plastic Mounting Kit
Mounting Ring Nut for 30.5mm holes.
Used on 30.5mm devices.
Plastic
800Z-G3AH1
Plastic Mounting Kit
57mm (2.25in)
Extension
60-2681
30.5mm Swivel/Tilt Mounting Assembly
This bracket allows you to orient the touch button in any
position. It can be mounted on any vertical or horizontal
surface. Compatible with 30.5mm mounting only.
29mm (1.15in)
Extension
60-2439
Swivel Assembly
Shiny Metal
30.5mm to 22.5mm Hole Size Adaptor
This adaptor allows a 22.5mm push button operator to be
installed in a panel with existing 30.5mm mounting holes.
Black Metal
800E-AHA1
800E-AHA2
Adaptor
11-4
Two-Hand Control Devices
Zero-Force Touch Buttons
800Z General Purpose
Approximate Dimensions—mm (inches)
40.9
(1.61)
48.3
(1.90)
22mm
Version
Micro Quick
Disconnect
56.9
(2.24)
129.3 (5.09)
35.1
(1.38)
69.9 (2.75)
40.9
(1.61)
30mm
Version
Mini Quick
Disconnect
22mm
Version
Cable
40.9
(1.61)
22.4
(0.88)
129.3 (5.09)
110.3
(4.34)
39.4
(1.55)
General Purpose with Guards
40.9
(1.61)
30mm
Version
Cable
22.4
(0.88)
General Purpose
Typical Wiring Diagram
Electrical Connections: 10...40V DC and 20...30V AC Input Voltage (Relay Output); 85...264V AC Input Voltage (Relay Output)
Note:
Separate N.O. and N.C. output relays with shared common.
Brown (+) L1
Blue (-) L2
Black (N.O.)
White (N.C.)
Gray (Common)
5 Conductor Cabled (Relay Output) for 800Z-GL_ _ _
Electrical Connections: 10...30V DC Input Voltage (Transistor Output); 150mA max. per circuit output
(+)
(-)
(+)
(-)
Brown (+) Blue (-)
Load Black (N.O.)
White (N.C.)
Load
Brown (+) Blue (-)
Black (N.O.) Load
White (N.C.)
Load
4 Conductor Cabled Sinking (NPN)
4 Conductor Cabled Sourcing (NPN)
Applications Details
LED Blink Rate
** ** **
*** *** ***
**** **** ****
Diagnostic
Power Up
Noise Detection
Margin Detection
Description
Device touched during power-up. Device will resume 10 seconds after removal of hand.
Device detected an unacceptable level of noise (>20V/m). Device will resume once noise
subsides.
A conductive film is building up on the sensing surface. Device will resume once cleared.
Hey guys, I have an assignment to do, which is to use eight three-digit digital tubes to display the number of key presses. Can anyone recommend a solution? I think the difficulty of the problem is th...
Hello everyone!!! I am a worthless person! I send spam messages!!! I deserve to die!!! My wife gave birth to a child without an anus, and the child even had a small penis on its face!! My wife ran off...
Contactless sensing of the linear or rotational position of nearby objects in electrically and mechanically harsh environments is a common system requirement. Several approaches exist to meet this goa...
ConceptPWM signal is a digital signal with fixed period and indefinite duty cycle.If the counter of Timer_A works in up-counting mode, the output adopts output mode 7 (reset/set mode)and uses register...
Many netizens will definitely encounter various questions when learning TI Stellaris. This is a good communication platform. Whether you are an engineer or a student, you can raise any questions and l...
On August 24th, Tesla CEO Elon
Musk
revealed information about the upcoming FSD V14, claiming it will outperform human drivers. Tesla FSD lead Ashok stated last year that FSD version 12.5, ...[Details]
On August 23rd, Geely's subsidiary, Jiyao Tongxing, announced it has the industry's largest advanced production capacity for tandao
batteries
, with eight production bases across China. Jiy...[Details]
When you are happily watching NBA or football, your wife asks you to turn off the lights in the bedroom. Would you be depressed? Of course, unless you are not afraid of your wife.
Now you are ...[Details]
New energy pure electric vehicles generally accelerate faster than comparable fuel-powered vehicles, both from a standing start and while accelerating. Many believe this is simply due to the motor'...[Details]
Electric vehicles' 12V batteries don't rely on a generator to power them. Only gasoline-powered vehicles rely on the engine to drive a generator to generate electricity while driving, which is used...[Details]
1. Ease of Use: The HMI module should be designed to be simple and clear, allowing users to easily operate and configure the energy storage device.
2. Ease of Maintenance: The HMI module should...[Details]
On August 22, according to CNBC's report today, the National Highway Traffic Safety Administration (NHTSA) is launching an investigation into Tesla, and the latter is questioned whether it has fail...[Details]
On August 22, the Wall Street Journal reported on the 21st local time that the new US government does not plan to acquire equity in semiconductor wafer foundry giant TSMC and Micron, one of the thr...[Details]
Magna's integrated in-cabin perception system fuses vision and millimeter-wave radar data to detect the presence of passengers, identify stranded children, monitor driver fatigue and vital signs, a...[Details]
Lightweighting of automobiles is still a relatively unfamiliar term for automobiles. With the continuous improvement of environmental protection requirements, relevant regulations have also put for...[Details]
I recently read an article in the Wall Street Journal titled "We need the right to repair our gadgets" (reference original article: ). The author was very angry about the phenomenon of "planned obs...[Details]
The fracture mechanism is stress concentration, which typically occurs at the capacitor lead pins or pad connection points, as shown in the figure. Under vibration, the capacitor lead pins and pad ...[Details]
Batteries are a core component of new energy vehicles, accounting for over 40% of the total cost. This is also the area where automakers are most willing to tamper with costs. Since 2021, domestic ...[Details]
Lithium-ion batteries are a key component of electric vehicles. Their high energy density enables them to store a large amount of energy in a relatively compact and lightweight package, which is cr...[Details]
Traditionally, electrical energy is transmitted primarily through wires, requiring direct physical contact between the power source and the load. With the increasing number of electrical devices in...[Details]