800TC-FX6A1S

Description
Push Buttons
File Size157KB,7 Pages
ManufacturerALLEN BRADLEY
Download Datasheet View All

800TC-FX6A1S Overview

Push Buttons

Emergency Stop Devices
Push Buttons
800 E-Stops
!
Specifications—22.5mm
Front of Panel (Operators)
Mechanical Ratings
Description
Vibration (assembled to
panel)
Shock
Degree of protection
Mechanical design life
(typical)
Plastic
(800EP/ES)
Metal
(800EM/EB)
Back of Panel Components
Electrical Ratings
Description
Standard contact block
ratings➋
2-Across Style
3-Across Style
NEMA, EEMAC
NEMA, A600,
A600, Q600, VDE
Q600, 600V AC;
0660; AC15, DC 13 AC15, DC 13 to
to IEC 947
IEC 947
10A max.
10A max. without
continuous current enclosure (40°C
to UL508, CSA22.2 (104°F) ambient) 6A
#14, IEC 947, VDE with enclosure
0660, part 200
(60°C (140°F))
Conforming to CENELEC EN50013
Min of (1) #20AWG #18 to #12AWG
Max of (2)
(0.75 to 2.5mm
2
)
#14AWG or (1)
Max (2) #14AWG
#12AWG
or (1) #12 AWG
2,200V for one minute
1,000,000 at 2A
Finger-safe conforming to IP2X
10 to 2000Hz, 1.52mm displacement
(peak-to-peak) max./10g max.
1/2 cycle sine wave for 11ms and no
damage at 100g
IP66 (NEMA Type 3, IP66 (NEMA Type 3,
3R, 4, 4X, 12, 13)
3R, 4, 12, 13)
500,000 cycles:
mushroom
100,000 cycles:
operators
mushroom key
operators (plastic),
push-pull/twist
50,000 cycles:
operators
mushroom key
operators (metal)
-25°C to +55°C (-13°F to +131°F)
-40°C to +70°C (85°C max. for 24 hours)
-40°F to +158°F (185°F max. for 24 hours)
Thermal current
Terminal marking
Wire capacity (screw
terminal)
Environmental
Temperature range
(operating): per IEC 947-1
Temperature range (short
term storage): per IEC
947-1
Materials
Bushings, mounting rings
Dielectric strength (min)
Electrical design life cycles
Electrical shock
protection: Per IEC 529
Mechanical Ratings
Vibration
Shock
Glass-filled
thermoplastic
polyester, rated
UL94 V-O
Glass-filled
thermoplastic
polyester, rated
UL94 V-O
Silicone rubber
Nitrile rubber
Die-cast zinc; dark
olive chromate
finish
Anodized aluminum
(EB, EM, ES line)
Bezels
Contact block mechanical
design
Contact operation
10 to 2000Hz
1.52mm
displacement (peak-
to-peak) max./10g
max. 6hr
1/2 cycle sine wave
for 11ms and no
damage at 100g min
5,000,000 cycles
10 to 150Hz
0.15mm
displacement (peak-
to-peak) max./2g
max. 6hr
1/2 cycle sine wave
for 11ms and no
damage at 50g max
Operating forces (typical)
Environmental
Temperature range
Operating
➋➌
Short term storage
Materials
Springs
Electrical contacts:
Standard
Low voltage
Seals: diaphragm style
Seals: lip and flat gasket
styles
Illuminated lenses
N.C. slow make, double break (positive
opening); N.C.L.B. late break, double
break (positive opening)
2.78N: all contact
2.6N: each N.C.
blocks
contact block
Transparent nylon Type 12
-25°C to +55°C (-13°F to +131°F)
-25°C to +55°C (70°C max for 24 hrs)
(-13°F to +131°F (158°F max for 24 hrs))
Stainless steel and zinc coated music wire
!
See Performance Data: refer to page Important-2 of the A113
Industrial Controls
catalogue.
Operating temperature below 0°C (32°F) are based on the absence of freezing
moisture and liquids.
Per IEC 947-1.
UL File & Guide Number E14840.
Silver nickel alloy
Fine silver
Palladium silver
Gold-plated over
alloy: spanner; gold- silver
plated silver nickel:
stationary contacts
Terminals:
Screw type Plated steel
Push-on type
Agency approvals
Approvals
UL listed
➍/CSA
certified
Standard conformity
UL508, UL486E
NEMA ICS-1 and
CSA22.2 #14,
ICS-2 IEC 204-1,
NEMA ICS-1 and
947; SEV 1005,
ICS-2 (1983), IEC
1093; VDE 0113,
144, IEC 947-1, IEC 0660 Part 201; BS
947-5, VDE 0550,
4794; CEE 24; UL
VDE 0660, Part 200 486E, UL 508,
CSA22.2 #14
6-14
Has anyone ever disassembled an Apple PRO charger?
There is no relevant information on the Internet. It is very frustrating. Has anyone ever disassembled the charger of Apple PRO? It is said that it is not closed by snaps, but it seems to be glued. So...
cardin6 Creative Market
Summary of some common USB 2.0 test problems
USB2.0 testing is the most common test for engineers. Its testing is very mature and has a very complete set of specifications. In actual work, some engineers still have some doubts about USB2.0 testi...
快羊加鞭 Download Centre
PCI9054, download FPGA local program, host computer freezes
As the title says: PCI9054, downloading FPGA local program, the host computer freezesThe FPGA program is written strictly according to the working principle of 9054. The simulation passes, but the hos...
飞天猪run FPGA/CPLD
Low-power wireless transmission technology required in the Internet of Things
[font=Microsoft True Black][color=#000000][size=16px] [/size][/color][/font] [font=Microsoft True Black][color=#000000][size=16px] [/ size][/color][/font] [font=Microsoft Blackbody][color=#000000][siz...
dontium RF/Wirelessly
What does it mean to prevent JTAG failure?
Define the button, why is it PB5? I see that many versions have different pins for the button settings? Please tell me, I'd be very grateful!// 定义KEY#define KEY_PERIPH SYSCTL_PERIPH_GPIOB#define KEY_P...
jinghong21 Microcontroller MCU
Smart clock with 8 alarm settings (with schematic diagram)
[color=#000000][font=宋体][size=10.5pt]Ordinary home clocks can only set one alarm time, but many people need to set different alarm times for different time periods such as weekdays, weekends, mornings...
Uxianzhang DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 500  499  937  736  27  11  19  15  1  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号