See Performance Data: refer to page Important-2 of the A113
Industrial Controls
catalogue.
➋
Operating temperature below 0°C (32°F) are based on the absence of freezing
moisture and liquids.
➌
Per IEC 947-1.
➍
UL File & Guide Number E14840.
Silver nickel alloy
Fine silver
Palladium silver
Gold-plated over
alloy: spanner; gold- silver
plated silver nickel:
stationary contacts
Terminals:
Screw type Plated steel
Push-on type
Agency approvals
Approvals
UL listed
➍/CSA
certified
Standard conformity
UL508, UL486E
NEMA ICS-1 and
CSA22.2 #14,
ICS-2 IEC 204-1,
NEMA ICS-1 and
947; SEV 1005,
ICS-2 (1983), IEC
1093; VDE 0113,
144, IEC 947-1, IEC 0660 Part 201; BS
947-5, VDE 0550,
4794; CEE 24; UL
VDE 0660, Part 200 486E, UL 508,
CSA22.2 #14
6-14
Emergency Stop Devices
Push Buttons
800 E-Stops
Product Selection—22.5mm
2-Position Push-Pull Operators, Non Illuminated—Twist-to-Release, Push-Pull
40mm Trigger Action
Twist-to-Release Mushroom
40mm Twist-to-Release Mushroom
40mm Push-Pull Mushroom
800E-15YE112
Legend Plate for 40mm Ca
Colour
Operator Material
Plastic
Metal
40mm Mushroom Operator
Twist-to-Release — Round (Trigger Action)
!
Push-Pull Twist-to-Release — Round
➋
Push-Pull — Round
➋
Catalogue Number
800EP-MTS44
800EM-MTS44
800EP-MT4
800EM-MT4
800ES-MP24
800EM-MP24
Red
Plastic
Metal
Plastic
Metal
2-Position Trigger Action Operators, Non Illuminated—Key Release
➌
40mm Key Release Mushroom
60mm Key Release Mushroom
800E-16YE112
Legend Plate for 60mm Cap
Colour
2 Position Trigger Action
!
Mushroom Operator
Ronis Key Lock
Size
40mm—Round
60mm—Round
40mm—Round
60mm—Round
Catalogue Number
800EP-MKR44
800EP-MKR64
800EP-MKZ44
800EP-MKZ64
Red
Zadi Key Lock
Back-of-Panel Components, Non Illuminated Operators
Mounting Latch and
Contact Block Combination
Mounting
2-Across
Contact
➊➋
1 N.C. Late break
1 N.O. - 1 N.C. Late break
1 N.C. Late break
1 N.O. - 1 N.C. Late break
1 N.C. Self-monitoring
3-Across
800E-3LX01S
!
Trigger action operators are compliant with EN418 standards using standard N.C., N.C. Late Break, or N.C. Self-Monitoring contact blocks. Key Release operators are
IP66, Type 4/13.
➋
Emergency stop push buttons are compliant with EN 418 standard when using N.C. Late break (N.C.L.B.) contact blocks.
➌
Key release operators are IP66, Type 4 and 13.
2-Across
3-Across
Catalogue Number
800E-2LX01L
800E-2LX11L
800E-3LX01L
800E-3LX11L
800E-2LX01LS
3-Across
2-Across
6-15
Emergency Stop Devices
Push Buttons
800 E-Stops
Product Selection—22.5mm
2-Position Red Push-Pull Operators, Illuminated —Mushroom
➊
40mm Mushroom Push-Pull
60mm Jumbo Mushroom Push-Pull
800E-15YE112
Legend Plate for 40mm Cap
Operator Material
Plastic
Size
40mm
60mm
40mm
Catalogue Number
800ES-LMP24
800ES-LMJP24
800EM-LMP24
800EM-LMJP24
Metal
60mm
Back-of-Panel Components,
Illuminated Operators
2-Across
(5 ckts. max.)
3-Across
(4 ckts. max.)
Mounting
Type
Incandescent
Volts
24 AC/DC
120 AC/DC
Catalogue Number
800E-2DL3
800E-2DL5
800E-2DL3R
800E-2DL5R
800E-3DL3
800E-3DL5
800E-3DL3R
800E-3DL5R
800E-2TL5
800E-2TL7
800E-2TL5R
800E-2TL7R
800E-3TL5
800E-3TL7
800E-3TL5R
800E-3TL7R
2-Across
24 AC/DC
LED (red)
120 AC
24 AC/DC
Incandescent
Full Voltage Power Module with Latch
3-Across
LED (red)
Incandescent
2-Across
LED (red)
Incandescent
3-Across
Transformer Power Module with Latch
2-Across
3-Across
120 AC/DC
24 AC/DC
120 AC
24 AC/DC
120 AC/DC
24 AC/DC
120 AC
24 AC/DC
120 AC/DC
24 AC/DC
LED (red)
120 AC
2-Across (3 ckts. max.)
3-Across
(2 ckts. max.)
2-Across
Late Break
!
800E-2X01L
1 N.C. Late break
800E-3X01L
3-Across
Contact Blocks
!
Emergency stop push buttons are compliant with EN 418 standard when using N.C.L.B. contact blocks.
6-16
Emergency Stop Devices
Push Buttons
800 E-Stops
!
Specifications—30.5mm
Electrical Ratings
Dielectric strength
Electrical design life cycles
Mechanical Ratings
Vibration
2200V for one minute
1,000,000 at max. rated load
10 to 2000Hz 1.52mm displacement
(peak-to-peak) max./10g max. (except
Logic Reed)
1/2 cycle sine wave for 11ms
≥25g
(contact fragility) and no damage at 100g
Type 1, 4, 4X, 12, 13; watertight/oiltight
IEC 529 IP66/65
Shock
Degree of protection
Mechanical design life
cycles
250,000 min.
(Push-pull/twist-to-release)
Contact operation
Shallow, mini, and low voltage contact
blocks: Slow, double make and break.
Typical operating forces
7.5lbs max. push or pull
2-position push-pull
Environment
Temperature range
Operating
➋
-40°C to +55°C (-40°F to +131°F)
Storage
-40°C to +85°C (-40°F to +185°F)
Standard Contact Ratings
Maximum thermal continuous current
I
th
10A AC/2.5A DC.
Bulletin 800T units with 800T-XA contacts have ratings as follows:
Max.
Opertnl.
Volts Ue
Utilization
Category
IEC
NEMA
A600
Rated Operational Currents
Volts Ue
120 to 600
72 to 120
24 to 72
28 to 600
24 to 28
➌
Make
Break
7200VA
720VA
60A
720VA
60A
10A
69VA
2.5A
AC 600
AC-15
DC 600
DC-13
Q600
!
Performance Data: see publication A113, page Important-2.
➋
Operating temperatures below freezing are based on the absence of moisture
and liquids.
➌
For applications below 24V/24mA, PenTUFF contacts are recommended.
6-17
Emergency Stop Devices
Push Buttons
800 E-Stops
Product Selection—30.5mm
Emergency Stop Operators — 2-Position Red Non Illuminated
2-Position Push-Pull
2-Position Push-Pull/Twist
Operator Position
Contacts Maintained Out Maintained In
Enclosure
Protection
Type 4 & 13
Release
Push-Pull
Catalogue Number
800T
-FX6D4
800T
-FXT6D4
N.C.L.B.
!
Closed Open
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
N.O. Open Closed
N.C.L.B.
!
Closed Open
Type 4 & 13
800T
-FXT6A1
Push-Pull/Twist
Type 4, 4X & 13
N.C.L.B.
!
Closed Open
N.C.L.B.
!
Closed Open
Push-Pull
Type 4 & 13
800T
-FXT6A5
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
S.M.C.B.
➊➋
Closed Open
Type 4 & 13
800TC-FXT6D4S
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
N.O. Open Closed
S.M.C.B.
➊➋
Closed Open
Type 4 & 13
800TC-FXT6A1S
Push-Pull/Twist
Type 4, 4X & 13
Push-Pull
S.M.C.B. Closed Open
S.M.C.B.
➊➋
Closed Open
Type 4 & 13
800TC-FXT6A5S
Push-Pull/Twist
Type 4, 4X & 13
Note:
Emergency stop push buttons are compliant with EN-418 and IEC 60947-5-5 Standards when using N.C.L.B. contact blocks.
➊
Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts
change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs.
➋
The Self-Monitoring Contact Block (S.M.C.B.) is composed of a N.C.L.B. contact wired in series with a N.O. monitoring contact. The N.O. monitoring contact automatically
closes when the S.M.C.B. is properly installed onto the E-Stop operator. If the S.M.C.B. is separated from the E-Stop operator, the N.O. monitoring contact will
I wrote a multi-function clock and automatic bell system, which can set 16 bell points (divided into 8 classes). I wrote more than 1500 lines. After compiling, I found code:7283. Is it because my prog...
[i=s]This post was last edited by yangjiaxu on 2018-11-22 01:21[/i] Thanks to the community and Cypress Semiconductor for their development board support. I received the development board the day befo...
This article takes USART1 as an example to describe the programming process of serial port interrupt.
1. Let's first talk about some library files involved in applying serial port interrupts.
First of...
The weather is very cold tonight this year. The mouse is as cold as the machine. What's hateful is that I have to continue using it until dawn, even though my hands are frozen! Webmaster's note: This ...
1. Equipment Overview
Shell-and-tube heat exchangers are a common heat exchange device used in chemical evaporation and heating equipment. Currently, the tubesheets of shell-and-tube heat exch...[Details]
Nios II is a configurable 16-/32-bit RISC processor. Combined with a rich set of peripheral-specific instructions and hardware acceleration units, it provides a highly flexible and powerful SOPC sy...[Details]
Since its invention in the mid-1940s, the microwave oven has evolved from a humble beginning to commercial use, entering homes in the 1960s and rapidly gaining popularity. Its basic functionality a...[Details]
Electric vehicles' 12V batteries don't rely on a generator to power them. Only gasoline-powered vehicles rely on the engine to drive a generator to generate electricity while driving, which is used...[Details]
Lightweighting of automobiles is still a relatively unfamiliar term for automobiles. With the continuous improvement of environmental protection requirements, relevant regulations have also put for...[Details]
With growing environmental awareness, the continuous improvement of three-electric technology and the increasing deployment of infrastructure such as charging stations, the electrification of new e...[Details]
On August 21, it was reported that Intel's new generation of AI chip Jaguar Shores was recently exposed for the first time.
According to photos shared by Andreas Schilling, the Jaguar Shores t...[Details]
introduction
As core electronic components used in vastly different fields, automotive-grade chips and mobile/consumer-grade chips exhibit significant differences in their...[Details]
introduction
With the development and widespread use of integrated circuits in power electronics design, electronic products are trending towards smaller sizes, more components, and greater fu...[Details]
Traditionally, electrical energy is transmitted primarily through wires, requiring direct physical contact between the power source and the load. With the increasing number of electrical devices in...[Details]
Blackfin® 16-/32-bit embedded processors offer high performance, low power consumption, flexible software features, and scalability, making them suitable for converged applications such as multi-fo...[Details]
The motor is a very important component for new energy vehicles. In terms of vehicle power, pure electric vehicles use electric motors instead of traditional diesel/gasoline engines. For electric v...[Details]
Using an electronic load is like thinking of it as a resistor that dissipates the power supply's output. The most straightforward mode is the CR constant resistance mode. In this mode, by setting a...[Details]
On August 19, Reuters reported that people familiar with the matter said that Nvidia is developing a new AI chip based on its latest Blackwell architecture for the Chinese market. The performance o...[Details]
Mathematical functions are very important and are used in many situations such as analog quantity processing and PID control.
(12) Calculate sine value instruction (SIN)
The "Calculate Si...[Details]