EEWORLDEEWORLDEEWORLD

Part Number

Search

800E-N169R

Description
Cable (Rope) Pull Switches
File Size172KB,6 Pages
ManufacturerALLEN BRADLEY
Download Datasheet View All

800E-N169R Overview

Cable (Rope) Pull Switches

Emergency Stop Devices
Cable (Rope) Pull Switches
Lifeline 4
Specifications
Standards
Approvals
Safety Contact
Designation/Utilization Cat.
A600/AC-15 (Ue)
(Ie)
N600/DC-13 (Ue)
(Ie)
Thermal Current (lth)
Minimum Current
Safety Contact Gap
Rtd. Insulation Voltage
Rtd. Impulse withstand
Voltage
Pollution Degree
Max. Actuation Frequency
Case Material
Eye Nut Material
Emergency Stop & Indicator
Material
Protection
Conduit Entry
Operating Temperature
Operation Force
Max Cable Span Between
Switches
Fixing
Mounting
Mechanical Life
Weight
Colour
EN60947-5-5, ISO13850, ISOTR 12100,
IEC 60947-5-1, EN 418
CE marked for all applicable directive,
cULus and BG
2 N.C. or 3 N.C. or 4 N.C. direct
opening action
600V 500V 240V 120V
1.2A 1.4A 3A 6A
600V 500V 250V 125V
0.4A 0.55A 1.1A 2.2A
10A
5V 5mA
>2 x 2mm (0.078in)
(Ui) 500V
(Uimp) 2500V
3
1 Cycle per sec
Heavy duty die cast alloy
Stainless Steel
Acetal
IP66
3 x M20, 3 x 1/2in NPT, quick-
disconnect style
-25°C to 80°C (-13°F to 176°F)
<125N (300mm deflection;
28.1lb deflection)
75m (246ft) standard model
75m to 125m extended length model
4 x M5
Any position
1,000,000
630g (1.38lb)
Yellow body, Red E-Stop button,
Blue reset button
Description
The Lifeline 4 cable/push button operated system can be installed
along or around awkward machinery such as conveyors and provide
a constant emergency stop access.
The Lifeline 4 is the only device of its kind to incorporate the
following features in one unit making it the most versatile cable
switch on the market.
1. The positive mode mechanism ensures that the contacts are
immediately latched open on actuation and can only be reset by
the intentional action of turning the blue reset knob. The design
also protects against nuisance tripping and the effects of thermal
expansion.
2. A mushroom head emergency stop button is included on the unit
to provide E-Stop access even at the extreme ends of the span.
3. The cable status indicator makes the system easy to set up and
maintain for spans up to 125 meters.
4. Four sets of contacts are provided: 2 N.C. + 2 N.O., 3 N.C. +
1 N.O., or 4 N.C. contacts.
5. Sealed to IP 66 with rugged construction using die cast alloy and
stainless steel to withstand harsh conditions.
Features
• Switches up to 125 meter span
• Universal mounting and operation
• Lid mounted emergency stop button, designed to conform to
EN418
• Switch lockout on cable pulled and cable slack
• Cable status indicator on switch lid
Lid mounted E-Stop button
A mushroom head emergency stop
button is included on the unit to
provide total E-Stop access even at
the extreme ends of the span.
Important:
It is recommended that the LRTS (Lifeline
Rope Tensioning System) should be used
with the Lifeline 4 cable rope switch.
Cable status indicator on
lid
The cable status indicator makes
the system easy to setup and
maintain for spans up to 125
meters.
6-8
Wolf culture laughs at beauty's fall into rogue culture (reprint)
On May 25, 2009, Xinhua News Agency’s Oriental Outlook Weekly published an article titled “The Business War Driving Force Behind the Frequency Conversion Chaos” which shook the Chinese air-conditionin...
兔子吃玉米 Talking
Newbies, please take a look at the S3C2440 used by TQ2440
I'm a new user, thanks for browsing. I bought a TQ2440 development board based on S3C2440. I have some basic knowledge of programming and I want to get started with embedded development. Now I sincere...
royal1990 Linux and Android
nk.bin stopped burning halfway through, and there was no error message. Help is needed if you are in a hurry!
I bought a tq2440 development board and made a development board based on it. The bootload and image I use now are all provided by tq2440. I use jlink to burn uboot into st39vf1601, and then start fro...
tancloud Embedded System
What is the function of 74LS373? Hope it is easy to understand
I checked Baidu and still don't understand it. [[i] This post was last edited by godyness on 2011-12-22 22:01 [/i]]...
godyness 51mcu
Problems with paste layer and solder layer
Pin 2 is a straight-in pad, and pin 8 is a surface mount pad. As shown in Figure 1, only open the silk screen layer and the top layer, then check the PCB board, and you will find that the green part o...
shaorc PCB Design
PIC Header Files
I wrote a project in MPLAB ICD and defined two header files. When simulating, it shows "can't open include file "main.h". What should I do?...
xzfx Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 679  1538  2763  804  547  14  31  56  17  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号