EEWORLDEEWORLDEEWORLD

Part Number

Search

88922-N122LF

Description
Board Connector, 48 Contact(s), 4 Row(s), Male, Straight, 0.079 inch Pitch, Press Fit Terminal, Locking, White Insulator, Receptacle, LEAD FREE
CategoryThe connector    The connector   
File Size717KB,7 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

88922-N122LF Overview

Board Connector, 48 Contact(s), 4 Row(s), Male, Straight, 0.079 inch Pitch, Press Fit Terminal, Locking, White Insulator, Receptacle, LEAD FREE

88922-N122LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid2128854065
package instructionLEAD FREE
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL8.6
Other featuresPOLARIZED
body width0.622 inch
subject depth0.67 inch
body length0.942 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedTin (Sn)
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleBLADE PIN-SKT
DIN complianceNO
Dielectric withstand voltage1400VAC V
Filter functionNO
IEC complianceNO
maximum insertion force12.0096 N
Insulation resistance1000000000 Ω
Insulator colorWHITE
insulator materialGLASS FILLED LIQUID CRYSTAL POLYMER
JESD-609 codee3
MIL complianceNO
Manufacturer's serial number88922
Plug contact pitch0.079 inch
Match contact row spacing0.079 inch
Mixed contactsNO
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number4
Number of rows loaded4
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
PCB contact row spacing2.0066 mm
polarization keyPOLARIZED HOUSING
Rated current (signal)1.5 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal pitch2 mm
Termination typePRESS FIT
Total number of contacts48
UL Flammability Code94V-0
Evacuation force-minimum value4.8928 N
1
2
3
4
PRODUCT NUMBER
SEE TABLE
22.00 REF
2.00 REF
1.40 REF
POS.1
12
2.30 REF
0.50 REF
D
C
B
A
17.00 REF
3.45 REF
6.00 REF
15.80 REF
11.50 REF
2.00 REF
CONTACT AREA
2.00 REF
A
23.93 REF
DIM A 0.1
SEE NOTE 8
DIM B REF
SEE NOTE 8
A
CONFIDENTIAL and PROPRIETARY information of FCI.
This document is the property of and embodies
to others without the written consent of FCI.
document may be used in any way or disclosed
No part of the information shown on this
mat'l code
--
ecn no.
dr
date
tolerances unless
otherwise specified
CUSTOMER
COPY
projection
title
www.fciconnect.com
ltr
0.X
linear
0.3
0.13
.051
2
AU
AV
-
AP
AR
AS
AT
V06-0569 DCH
DG09-0256
TER
-
-
V04-0913 HTB
V04-0990 DAI
V05-0053 TAB
V05-0368 DPU
revision
sheet
2006-06-13
2009-08-19
0.XX
.XXX
-
09/09/04
09/30/04
02/17/05
06/01/05
AV
1
AV
2
Pro/E
angles
dr
engr
chr
appd
Copyright FCI.
0
METRAL SIGNAL HEADER
2 MOD, 4 ROW PRESS-FIT
METRAL
code
dwg no
T.BRUNGARD
M.STRAWSER
M.STRAWSER
M.STRAWSER
11/19/99
11/19/99
11/19/99
02/29/00
scale
MM
product family
size
2:1
A
88922
cage code
213
sheet
1 of 7
B
sheet
AV
3
AV
4
AV
5
AV
6
AV
7
3
B
1
REV E - 2006-04-18
index
2
22526
4
PDM: Rev:AV
STATUS:
Released
Printed: Jan 17, 2011
.
I have a question, how to send the video data of the application (APP) to the TD (3G) module?
I have a question, how to send the video data of the application (APP) to the TD (3G) module?...
glenovo Embedded System
【Learning experience DLP】DLP introduction
DLP is the abbreviation of "Digital Light Procession", which means digital light processing. This technology requires digital processing of the image signal before projecting the light. It is a techno...
Sur TI Technology Forum
C6203B XBUS-XWE signal abnormal situation analysis after power-on reset
[table=98%] [tr][td][size=4][color=#000000][font=宋体]In our DSP system, a very strange phenomenon occurred: after the system was powered on and reset (cold reset), the -XWE/-XWAIT signal of the XBUS bu...
灞波儿奔 DSP and ARM Processors
How to disable menu function under WInCE
I used LoadMenu to load the menu, but the handle I got seems to be wrong, and I can't disable the menu. But I can use GetMenu, but this function doesn't work in WINCE. Please help, urgent...
shixing312 Embedded System
Does WinCE support directshow?
I searched the old posts on the forum and it said that video capture was not supported, but it could be played and stored. But that was a few years ago. Doesn't the current wince6 still support video ...
262476547 Embedded System
TMS320F2812 PWM program full Chinese analysis
[free]//#################################################################################### // // File name: Example_281xEvPwm.c // // Description: // Set up the event manager timers (TIMER1, TIMER2,...
寒江雪e Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1709  1589  490  2548  275  35  32  10  52  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号