Part Number

Search

D4C-5303

Description
Snap Acting/Limit Switch, SPDT, Momentary, 4.8mm, Wire Terminal, Crossroller Plunger Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size1MB,15 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

D4C-5303 Overview

Snap Acting/Limit Switch, SPDT, Momentary, 4.8mm, Wire Terminal, Crossroller Plunger Actuator, Panel Mount

D4C-5303 Parametric

Parameter NameAttribute value
MakerOMRON
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke4.8 mm
Actuator typeCROSSROLLER PLUNGER
body width16 mm
body height51.5 mm
Body length or diameter40 mm
Contact (AC) maximum rated R load.1A@125VAC
Maximum contact current (AC)0.1 A
Maximum contact voltage (AC)125 V
Electrical life200000 Cycle(s)
Manufacturer's serial numberD4C
Installation featuresPANEL MOUNT
Maximum operating force6.86 N
Maximum operating temperature70 °C
Minimum operating temperature-10 °C
Maximum pre-travel1.8 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
Base Number Matches1
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Sealing characteristics that meet IEC IP67 degree of
protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF cables with CE marking.
(Applicable only to standard models.)
CSM_D4C_DS_E_2_1
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1)(2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
1
The function simulation is correct, but it is not correct after downloading. Why?
I have encountered this situation several times. The simulation function is fine with modelsim, and the program is not complicated, but after burning it to the board, the function cannot be realized! ...
pinggougou FPGA/CPLD
What are the advantages and disadvantages of double-layer PCB and multi-layer PCB?
If you are interested, I hope you can share the characteristics, advantages and disadvantages of double-layer PCB and multi-layer PCB....
王小明A PCB Design
ZTXZTX talks about lead-acid battery maintenance
You will never learn without hands-on experience, and you will never improve without learning theories. The master will lead you to the door, and you must practice on your own. The problem is solved o...
zbz0529 Power technology
8086 address offset problem
Why is the address offset set to 4 bits? Because it has 20 address buses and the registers are 16 bits, so: 20-16=4? Then the 32-bit processor has a 32-bit address bus and a 32-bit register. Does it h...
lxy723 Embedded System
True 100m dual-mode Bluetooth
This Bluetooth module can transmit 100 meters in actual measurement, can transmit large amounts of data, and is stable and reliable.[b][color=#5E7384]This content was originally created by EEWORLD for...
freasycom2016 TI Wireless Connectivity
What is the difference and connection between the device GUID and the CUID in the inf file in driver development?
Looking forward to the experts’ help! Thank you!...
mtv0312 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 925  308  2235  1953  1406  19  7  45  40  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号