EEWORLDEEWORLDEEWORLD

Part Number

Search

UV28-12-A

Description
DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, 3/4 BRICK PACKAGE-11
CategoryPower/power management    The power supply circuit   
File Size1024KB,3 Pages
ManufacturerAstrodyne TDI
Download Datasheet Parametric View All

UV28-12-A Overview

DC-DC Regulated Power Supply Module, 1 Output, 240W, Hybrid, 3/4 BRICK PACKAGE-11

UV28-12-A Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerAstrodyne TDI
Parts packaging codeMODULE
package instruction,
Contacts11
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage32 V
Minimum input voltage20 V
Nominal input voltage28 V
JESD-30 codeR-XXMA-P11
JESD-609 codee0
length91.44 mm
Maximum load regulation0.2%
Number of functions1
Output times1
Number of terminals11
Maximum operating temperature100 °C
Minimum operating temperature-40 °C
Maximum output voltage13.2 V
Minimum output voltage10.8 V
Nominal output voltage12 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelINDUSTRIAL
Terminal surfaceTIN LEAD
Terminal formPIN/PEG
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output240 W
Fine-tuning/adjustable outputYES
width60.96 mm
Base Number Matches1
Astrodyne Corporation
35 Hampden Road
Tel: (508) 964-6300
Fx: (508) 339-0375
UV28
MICROVERTER
®
SERIES
28VDC INPUT
3/4 BRICK SINGLES
FULL BRICK TRIPLES
126-252 WATTS
DESCRIPTION
The µV28 Series are high density DC-DC
converters designed for use in telecom and
other centralized modular and distributed
power applications. The µV28 Series
use metal
PC boards, planar transformers,
and surface
mount construction to produce up to 252
watts in a tiny package.
FEATURES
• Miniature Size
• High Density – Up to 58 W/in.3
• Constant Frequency – 370KHZ
• Parallelable with Current Sharing
• Fault Tolerant – n+m Redundancy
• Extremely Low Thermal Resistance
• Output Good Signal
• Optional Sync Pin
• Non-Shutdown OVP
• Thermal Protection
• Current Limit/Short Circuit Protection
SINGLE OUTPUT
MODEL SELECTION
Model
µV28-2
µV28-3
µV28-5
µV28-8
µV28-12
µV28-15
µV28-24
µV28-28
µV28-T512
Output
Voltage
2.1V
3.3V
5V
8V
12V
15V
24V
28V
5V
12V
-12V
5V
15V
-15V
Output
Current
60A
50A
40A
30A
20A
16A
10A
9A
35A*
3A*
3A*
35A*
3A*
3A*
TRIPLE OUTPUT
µV28-T515
*Maximum Total Output Power 185 W.
Option: – A Output Good Deleted
– S Sync. Pin Option
www.astrodyne.com
www.roassoc.com
30
Astrodyne USA: 1-800-823-8082
Robot Manufacturing (III) Characteristics and Selection of Motors
[i=s] This post was last edited by paulhyde on 2014-9-15 09:22 [/i] The motor selection is crucial to the robot's performance...
Yound Robotics Development
Let me tell you something useful. Who knows how to set up a wireless router network?
I want to share a wireless network with my neighbors on the same floor. [align=center][/align] [align=left]It takes several wireless routers to cover the network. I want to use only one SSID and have ...
hightemplar Talking
Simple question about xdata unsigned char MYRAM _at_ 0xdfff
xdata unsigned char MYRAM _at_ 0xdfff After the definition, can MYRAM be changed in the program? For example, MYRAM++; I use a loop to write data to the off-chip data RAM in sequence. How can I implem...
xiaoyal Embedded System
How to diagnose terminal resistance failure in profibus
[align=center][font=punctuation, Microsoft YaHei, Tohoma][size=13.3333px][color=rgb(0, 0, 0)][font=Microsoft YaHei][color=#000000][size=26px]How to diagnose terminal resistance failure in profibus[/si...
hongkeanny Industrial Control Electronics
The problem caused by using char* as a parameter can be further explained.
void copywrite(char* string) { } void mystring(char* name) { copywrite(name); } 1 void main() { mystring("my name is"); } 2 void main() { char str[20]="my name is"; mystring(str); } Is there any diffe...
gongjun51201314 Embedded System
IFIX and S7-400 communicate using S7A
My system has multiple computers communicating with PLC. One of them is completely normal, but the others have the problems I mentioned below. IFIX communicates with 400, and the communication status ...
eeleader Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 215  1585  552  931  1046  5  32  12  19  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号