D4N-2A22

Description
Snap Acting/Limit Switch, DPST, Momentary, 2.5A, 250VDC, Screw Terminal, Roller Lever Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size5MB,20 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

D4N-2A22 Online Shopping

Suppliers Part Number Price MOQ In stock  
D4N-2A22 - - View Buy Now

D4N-2A22 Overview

Snap Acting/Limit Switch, DPST, Momentary, 2.5A, 250VDC, Screw Terminal, Roller Lever Actuator, Panel Mount

D4N-2A22 Parametric

Parameter NameAttribute value
MakerOMRON
Reach Compliance Codeunknown
ECCN codeEAR99
Factory Lead Time14 weeks
Actuator typeROLLER LEVER
Other featuresP.T.= 27 DEG, O.T.= 67 DEG
body width30 mm
body height57.5 mm
Body length or diameter31 mm
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)2.5 A
Contact (DC) maximum rated R load2.5A@250VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)250 V
Electrical life300000 Cycle(s)
Manufacturer's serial numberD4N
Installation featuresPANEL MOUNT
Maximum operating force5 N
Maximum operating temperature70 °C
Minimum operating temperature-30 °C
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionDPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSCREW
Base Number Matches1
Safety Limit Switch
D4N
CSM_D4N_DS_E_6_1
Popular Safety Limit Switches
Providing a Full Lineup Conforming to
International Standards
• Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and
3NC contact forms.
(Slow-action models with MBB contacts are available.)
• M12-connector models are also available, saving on labor and
simplifying replacement.
• Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
• Conforms to EN115, EN81-1, and EN81-2 (slow-action models
only).
• Certified standards: UL, EN (TÜV), and CCC
Be sure to read the
“Safety Precautions”
on page 17.
Note:
Contact your sales representative for details on models
with safety standard certification.
Model Number Structure
Model Number Legend
1-Conduit Models
2-Conduit Models
D4N-@@@@
1 2
3
1. Conduit size
1: Pg13.5
2: G1/2
4: M20
9: M12 connector
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top Plunger
32: Top Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE: Fork lever lock (right operation)
LE: Fork lever lock (left operation)
D4N-@@@@
1 2
3
1. Conduit size
6: G1/2
8: M20
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top Plunger
32: Top Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
1
【Original】Design of temperature sensor based on platinum resistance
[url=http://blog.ednchina.com/freeeedoooom/189387/message.aspx]http://blog.ednchina.com/freeeedoooom/189387/message.aspx[/url]...
freeeedoooom Sensor
AD package library 767M
My own collection of package libraries, mainly official libraries, and some self-made ones, etc., for those who are useful. Tips: Be sure to confirm the package and pin definition when using. It is no...
leng_qian PCB Design
Does PDA have a CPU? How to get the CPU serial number?
Does PDA have a CPU? How to get the CPU serial number?...
yeca3000 Embedded System
ADI sample express tracking number announced!
Sister SOSO, I haven't received my ADI samples yet:puzzle:-------------------------------------------------- -------------------------------------------------- ----------------------------------------...
drjloveyou ADI Reference Circuit
Please help me add an alarm and a stopwatch to the clock.
Simulation diagramThis is only a clock function, I want to add a stopwatch and alarm clock#include #define uint unsigned int#define uchar unsigned charsbit rs=P2^0; //define LCD display control portsb...
wsxzk 51mcu
Show the process of WEBENCH design + low-pass filter
The design of these filter devices takes up a large part in the simulation process. Some manufacturers do not have such equipment. Due to factors such as the environment, software simulation is perfor...
pleasemissme Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1334  886  1787  2281  2667  27  18  36  46  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号