D4C-2403

Description
Snap Acting/Limit Switch, SPDT, Momentary, 4.8mm, Wire Terminal, Crossroller Plunger Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size1MB,15 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Download Datasheet Parametric View All

D4C-2403 Overview

Snap Acting/Limit Switch, SPDT, Momentary, 4.8mm, Wire Terminal, Crossroller Plunger Actuator, Panel Mount

D4C-2403 Parametric

Parameter NameAttribute value
MakerOMRON
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke4.8 mm
Actuator typeCROSSROLLER PLUNGER
body width16 mm
body height51.5 mm
Body length or diameter40 mm
Contact (AC) maximum rated R load.1A@125VAC
Maximum contact current (AC)0.1 A
Maximum contact voltage (AC)125 V
Electrical life200000 Cycle(s)
Manufacturer's serial numberD4C
Installation featuresPANEL MOUNT
Maximum operating force6.86 N
Maximum operating temperature70 °C
Minimum operating temperature-10 °C
Maximum pre-travel1.8 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
Base Number Matches1
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Sealing characteristics that meet IEC IP67 degree of
protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF cables with CE marking.
(Applicable only to standard models.)
CSM_D4C_DS_E_2_1
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1)(2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
1
PIC16C7X A/D Converter Control Scheme
PIC16C7X A/D converter control scheme detailed introduction...
frozenviolet Microchip MCU
Please advise on the frequency setting of FLASH timing control generator
I'm writing a FLASH driver recently and encountered the following problem. I'd like to ask for your help. jelline@126.com(1) Clock frequencyThe FLASH timing generator frequency is required to be betwe...
Jelline Microcontroller MCU
【Date with Spring】Beautiful Scenery of Suzhou
I went on a business trip to Jiangnan a while ago, and took some time to visit Suzhou. Unfortunately, my camera was not very good, and I couldn’t pick out many satisfactory pictures. I’ll post them he...
liongt Talking
TO220 package and heat sink fixing problem
As shown in the figure above, a large round hole is opened on the PCB board, through which the screw cap can be passed. First, shape the TO220 package, solder it, and then place it on the radiator, an...
呜呼哀哉 Analog electronics
ST's LIS3DH three-axis accelerometer three-axis acceleration data offset calibration problem
I'm wondering if anyone is using ST's LIS3DH three-axis accelerometer. I need to use it to do a small project at work, which involves the calibration of the three-axis acceleration. I see that other t...
quake702 Mobile and portable
USB bootloader
Currently working on the bootloader of MKL26Z256VLL4 of Frescal, the AES decryption function is also added. First, the data is received by USB communication, the received data is decrypted by AES, and...
masonz NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2120  1989  466  456  948  43  41  10  20  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号