EEWORLDEEWORLDEEWORLD

Part Number

Search

PK01W-60-1MB

Description
Single Phase EMI Filter, 250V, 50/60HzHz,
CategoryAnalog mixed-signal IC    filter   
File Size529KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

PK01W-60-1MB Overview

Single Phase EMI Filter, 250V, 50/60HzHz,

PK01W-60-1MB Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresADDITIONAL COMPONENT BLEED RESISTOR
CertificationUL; CSA; VDE
filter typeSINGLE PHASE EMI FILTER
high17.5 mm
high potential2250 V
Maximum leakage current0.45 mA
length64.5 mm
Manufacturer's serial numberPK
Installation typePANEL MOUNT
working frequency50/60Hz Hz
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
physical sizeL64.5XB24.4XH17.5 (mm)/L2.539XB0.961XH0.689 (inch)
Rated current1 A
Rated voltage250 V
Base Number Matches1
PK Series
CHASSIS MOUNT, HIGH PERFORMANCE, MULTIPURPOSE,
SINGLE STAGE EMI/RFI LINE FILTER.
MECHANICAL DIMENSIONS
(Unit: mm)
A1, A2, A3
C
A
2x 4.8
D
B
E
10.0
G
DIMENSIONS
CASE
CODE A
B
C
F
G
D
E
24.4 45.0 17.5 64.5 54.1 8.5 49.6
A1
33.8 45.0 30.0 64.5 54.5 14.9 59.0
A2
46.5 51.8 30.0 70.9 60.9 14.9 71.7
A3
F
FEATURES
The PK series offers a wide variety of EMI filters in numerous
styles of packages and current ratings. The filters are effective
in reducing both Line-to-Line and Line-to-Ground noise up to
30 Amp at 250VAC. This series offers very low leakage
current suitable for medical and non-medical applications.
These filters are also available for Medical applications.
The absence of C(y) capacitors offers extremely low Leakage
current to comply with various industry standards especially
the medical equipment with Switching power supplies.
A Bleeder resistor can also be added to prevent excessive
voltages from developing across the filter capacitors when
there is no load.
51.5
B1
85.3
95.3
64.0
39.1
2x
4.8
(14.9)
(4.6)
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
G1
100.0
82.5
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 5A, 6A, 10A, 15A, 20A, 30A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
105.0
95.3
86.4
38.6
4X 6.5X4.0
50.8
(17.3)
(6.1)
Specifications subject to change without notice. Dimensions (mm).
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
35
Protel Tutorial
[i=s]This post was last edited by paulhyde on 2014-9-15 03:57[/i] Prepare for the next one and start with the basics!...
孤单南极 Electronics Design Contest
[Help] SIM300C sleep problem, why can't it connect to GPRS after sleep?
I am a novice, I hope you experts can help me~~~ I use SIM300C to transmit data via GPRS. After transmitting data once, I set the DTR pin to high level (the manual says that this can sleep). After tha...
z2661213 Embedded System
I would like to ask why the b ResetHandler in 44binit.s in S3C44b0 cannot jump
Hello everyone, I created a new project and added files on the S3C44b0 development board, and then compiled and simulated through ADS. As a result, I found that there was no response on the developmen...
rocky_z ARM Technology
The longer I stay up all night, the less sleepy I feel.
[i=s]This post was last edited by paulhyde on 2014-9-15 04:00[/i]The longer I stay up all night, the less sleepy I feel. It's the fourth day and it's almost over. Suddenly I feel like I still want to ...
jie900505 Electronics Design Contest
Pattern Classification, a foundational classic in the field of pattern recognition and scene analysis
[i=s]This post was last edited by tiankai001 on 2014-8-31 22:35[/i] [align=center][size=5] [/size][/align] [size=5][align=center]Pattern Classification[/align] [/size] [size=4] [color=#666666][font=Ar...
tiankai001 Download Centre
Capacitor Inductor
Does anyone have a diagram of the charge and discharge of capacitors and inductors?...
zhonghuadianzie Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1137  275  1178  2713  1037  23  6  24  55  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号