* The Generator Model Number identified in the table is for standard C Series Configuration. Consult the factory for alternate configuration.
** UL2200 Offered
2
// /
/
40-JC6dt3
FACTS
//
//
//
//
//
//
//
//
//
//
EPA Tier 3 Certified
Engine-Generator Set Tested to ISO 8528-5 for
Transient Response
UL2200, CSA Listing Offered
Accepts Rated Load in One Step Per NFPA 110, Level 1
All engine-generator sets are prototype and factory tested
MTU Onsite Energy is a single source supplier
Global Product Support
2 Year Standard Warranty
Custom Design for Any Application
4024HF285 Diesel Engine
- 2.4 Liter Displacement
- Electronic Unit Pump Injection
//
//
//
//
- 4-Cycle
Complete Range of Accessories
Permanent Magnet Generator (PMG) - Optional
- Brushless, Rotating Field
- 300% Short Circuit Capability
- 2/3 Pitch Windings
Digital Control Panel(s)
- UL Recognized,
, NFPA 110
- Complete System Metering
- LCD Display
Cooling System
- Integral Set-Mounted
- Engine Driven Fan
STANDARD EQUIPmENT
//
Engine
Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
130°C Standby Temperature Rise
1 Bearing, Sealed
Flexible Coupling
Full Amortisseur Windings
125% Rotor Balancing
3-Phase Voltage Sensing
±1% Voltage Regulation
100% of Rated Load - One Step
3% Maximum Harmonic Content
Air Cleaner
Oil Pump
Full Flow Oil Filter
Jacket Water Pump
Thermostat
Exhaust Manifold – Dry
Blower Fan & Fan Drive
Radiator - Unit Mounted
Electric Starting Motor - 12V
Governor – Electric Isochronous
Base - Formed Steel
SAE Flywheel & Bell Housing
Charging Alternator - 12V
Battery Box & Cables
Flexible Fuel Connectors
Flexible Exhaust Connection
EPA Certified Engine
//
digital Control Panel(s)
//
generator
NEMA MG1, IEEE and ANSI standards compliance for temperature rise
and motor starting
Sustained short circuit current of up to 300% of the rated current for up
to 10 seconds
Self-Ventilated and Drip-Proof
Superior Voltage Waveform
Digital, Solid State, Volts-per-Hertz Regulator
No Load to Full Load Regulation
Digital Metering
Engine Parameters
Generator Protection Functions
Engine Protection
SAE J1939 Engine ECU Communications
Windows-Based Software
Multilingual Capability
Remote Communications to our RDP-110 Remote Annunciator
16 Programmable Contact Inputs
7 Contact Outputs
UL Recognized,
, CE Approved
Event Recording
IP 54 Front Panel Rating with Integrated Gasket
NFPA110 Level Compatible
3
// /
/
40-JC6dt3
APPLICATION DATA
//
Engine
John Deere
4024HF285
4-Cycle
4 In-Line
146 (2.4)
3.4 (8.6)
4.1 (10.5)
18.2:1
1,800
JDEC
80 (60)
74 (55)
±.25%
60 Hz
Dry
//
Fuel Consumption
STANDBY
3.7 (14)
2.8 (10.6)
1.9 (7.2)
PRIME
3.2 (12.1)
2.5 (9.5)
1.7 (6.4)
Manufacturer
Model
Type
Arrangement
Displacement: Cu In (lit)
Bore: in (cm)
Stroke: in (cm)
Compression Ratio
Rated RPM
Engine Governor
Max Power: Standby: bhp (kWm)
Max Power: Prime: bhp (kWm)
Regulation
Frequency
Air Cleaner
At 100% of Power Rating: gal/hr (lit/hr)
At 75% of Power Rating: gal/hr( lit/hr)
At 50% of Power Rating: gal/hr (lit/hr)
//
Cooling - radiator System
STANDBY
122 (50)
0.5 (0.12)
26 (100)
1,560 (27.4)
484 (8.5)
411 (7.2)
PRIME
122 (50)
0.5 (0.12)
26 (100)
1,326 (23.3)
412 (7.2)
336 (5.9)
Ambient Capacity of Radiator: °F (°C)
Maximum Allowable Static
Pressure on Rad. Exhaust: in. H
2
0 (kPa)
Water Pump Capacity: gpm (lit/min)
Heat Rejection to Coolant: BTUM (kW)
Heat Rejection to Air to Air: BTUM (kW)
Heat Radiated to Ambient: BTUM (kW)
//
Liquid Capacity (Lubrication)
//
Air requirements
STANDBY
140 (4)
4,511 (128)
PRIME
133 (3.8)
4,511 (128)
Total Oil System: gal (lit)
Engine Jacket Water Capacity: gal (lit)
System Coolant Capacity: gal (lit)
2.1 (7.9)
0.68 (2.6)
3 (11.4)
//
Electrical
12
750
Electric Volts DC
Cold Cranking Amps Under 0°F (-17.8°C)
Aspirating: *SCFM (m /min)
Air Flow Required for Rad.
Cooled Unit: *SCFM (m
3
/min)
Air Flow Required for Heat
Exchanger/Remote Rad. based
on 25°F Rise: *SCFM (m
3
/min)
3
927 (26)
757 (22)
* Air density = 0.0739 lbm/ft
3
(1.184 kg/m
3
)
//
Fuel System
3/8” NPT
3/8” NPT
10 (3)
Diesel #2
21.7 (82)
//
Exhaust System
STANDBY
1,029 (554)
385 (10.9)
30 (7.5)
16 (4)
PRIME
1,008 (542)
354 (10)
30 (7.5)
16 (4)
Fuel Supply Connection Size
Fuel Return Connection Size
Maximum Fuel Lift: ft (m)
Recommended Fuel
Total Fuel Flow: gal/hr (lit/hr)
Gas Temp. (Stack): °F (°C)
Gas Volume at Stack
Temp: CFM (m
3
/min)
Maximum Allowable
Back Pressure: in. H
2
0 (kPa)
Minimum Allowable
Back Pressure: in. H
2
0 (kPa)
4
// /
/
40-JC6dt3
WEIGHTS AND DIMENSIONS
Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design.
System
OPU
dimensions (L x W x H)
82 x 34 x 48.38 in (2,080 x 860 x 1,230 mm)
Weight (less tank)
1,434 lb (650 kg)
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
SOUND DATA
unit type
OPU w/Critical Grade Muffler (dBA)
Sound Attenuated Enclosure (dBA)
Measurements for sound data are taken at 23 ft (7 m).
We know that although the screens of mobile phones are now made of wear-resistant glass, they are basically covered with protective films, otherwise small scratches will easily appear over time. The S...
[i=s]This post was last edited by ID.LODA on 2018-12-17 14:32[/i] [font=微软雅黑][size=4]Thank you very much for the evaluation opportunity provided by the community. [/size][/font][font=微软雅黑][size=4] [/s...
evn: ubuntu 10.04 arm-none-linux-gnueabi-gccgcc version 4.6.1 (Sourcery CodeBench Lite 2011.09-70) part of the log:In file included from route/link/can.c:32: ../include/netlink/route/link/can.h:33: wa...
I recently made a machine, using STM8105S4. It was OK during the small batch trial production. The second batch was more than 1,000 units. There was no problem during the production test. After instal...
The Sino-US trade war has already started. Trump's series of actions have had a negative impact on the global economy, such as increasing tariffs on Chinese companies and restricting domestic compa...[Details]
Designing for automotive LCD displays larger than 5" can be complex. The display source driver requires a supply rail called analog voltage device drain (AVDD) in the 10V to 15V range and two supply ...[Details]
In order to strengthen the management of new energy vehicle charging facilities in our city, prevent and reduce accidents, protect the lives and property of the people, and improve the public safet...[Details]
China Energy Storage Network News:
According to reports, in order to reduce carbon emissions, a group of Japanese technology and energy companies are launching a pilot project that aims to al...[Details]
1. Principle 1. Infrared emission protocol There are many infrared communication protocols. This experiment uses the NEC protocol. This protocol uses PWM modulation and uses pulse width to represen...[Details]
1. Test conditions Hardware: STM32L432KC Main frequency: 80MHz Compiler: IAR 8.20.1 Compiler options: High Speed no size constraints CRC generator polynomial: 0x782f 2. Test Method The softwar...[Details]
In the actual project development process, hardware circuits often need to be modified, and the modified parts need to modify the driver. Thinking about the coming and going of such requirements is t...[Details]
In simple terms, high-end chips solve many complex problems, mid-range chips solve a single complex problem, and low-end chips solve a simple problem. Let's learn more about the relevant content wi...[Details]
1. Photovoltaic inverter installation process
1. Preparation before installation
Are the product accessories, installation tools and parts complete? Is the installation environmen...[Details]
Today, under the guidance of a low-level expert, I learned how to configure the PWM module! Woof! First open the file configured last time, as follows: Then, we need to use TIM1 to set PWM: Then,...[Details]
0. Preparation First use st-link to connect the stm32 core board and PC for burning St-link Stm32 3.3V 3.3V GND GND SWDIO PART SWCLK DCLK Then connect with USB serial port board to v...[Details]
LAN8720 test code arrangement 1. Modified based on two projects, namely "Experiment 55 Network Communication Experiment" of Zhengdian Atom ATK and "STSW-STM32070" routine of ST official The hardware ...[Details]
I slightly changed the lyrics of Yu Quan's song "Running", which seems to be
a reflection of the current state of
Huawei Cloud
. At the annual Huawei Analyst Conference held on April 17,
Zh...[Details]
The application of millimeter wave technology in mobile communications also involves a series of technical problems, including the large propagation loss of millimeter waves and the susceptibility ...[Details]