EEWORLDEEWORLDEEWORLD

Part Number

Search

3331R102M6R3JS0

Description
-55 ⅹC to 105 ⅹC Ultra-Long-Life, Switching Power Grade Radial High Ripple and Ultra-Long Life
File Size357KB,5 Pages
ManufacturerETC
Download Datasheet View All

3331R102M6R3JS0 Overview

-55 ⅹC to 105 ⅹC Ultra-Long-Life, Switching Power Grade Radial High Ripple and Ultra-Long Life

Type 330
–55 °C to 105 °C Ultra-Long-Life, Switching Power Grade Radial
High Ripple and Ultra-Long Life
The Type 330 is the ultra-long-life version of the Type 300 capacitor.
With an astonishing, 50,000-hour
expected life operating
continuously at full load and 65 ºC the 330 is the choice for power
supply outputs and UPS battery stiffening. The exceptionally low
ESRs enable high ripple-current capability. With series inductance
of 12 to 16 nH and ripple currents to 16 amps one of these capacitors
can save by replacing three or four of the 12.5 mm diameter
capacitors routinely at the output of switching power supplies. Type
330 R delivers even lower ESR and higher ripple. Type 330 has three
leads for rugged, reverse-proof mounting. Two leads are available as
Types 331 and 331R.
Highlights
Specifications
Operating Temperature:
Rated Voltage:
Capacitance:
Capacitance Tolerance:
Leakage Current:
Cold Impedance:
Ripple Current Multipliers:
• Expected Life > 20 years @ 45 °C
• Ripple Current to 16 amps
• ESRs to 6
• > 90% capacitance at –40 °C
• Replaces multiple capacitors
–55 °C to +105 °C
6.3 to 250 Vdc
270 µF to 33,000 µF
6.3 to 100 Vdc; –10 + 75%, 160 to 250 Vdc; –10 + 50%
≤ 0.5 √CV µA, 4 mA max, 5 min.
–55 °C multiple of 25 °C Z ≤ 4 for 6.3 & 7.5 V, 3 for 10 to 50 V,
2 for > 50 V
Ambient Temperature
45 °C
1.66
55 °C
1.52
65 °C
1.37
75 °C
1.20
85 °C
1.00
95 °C
0.75
105 °C
0.36
Frequency
50 Hz 60 Hz 120 Hz
.77” Diameter
6.3 & 7.5 V
10 to 40 V
50V
63 & 75 V
100 to 250 V
.895” Diameter
6.3 & 7.5 V
10 to 40 V
50V
63 & 75 V
100 to 250 V
1.02” Diameter
6.3 & 7.5 V
10 to 40 V
50V
63 & 75 V
100 to 250 V
0.84
0.81
0.76
0.77
0.76
0.88
0.86
0.81
0.81
0.81
1.00
1.00
1.00
1.00
1.00
1.12
1.15
1.23
1.23
1.24
1.17
1.22
1.35
1.35
1.37
1.19
1.25
1.42
1.42
1.44
1.20
1.26
1.44
1.44
1.46
0.82
0.80
0.75
0.75
0.76
0.86
0.84
0.80
0.80
0.81
1.00
1.00
1.00
1.00
1.00
1.14
1.17
1.27
1.26
1.25
1.20
1.25
1.42
1.40
1.38
1.23
1.29
1.50
1.48
1.46
1.24
1.30
1.52
1.50
1.48
0.82
0.78
0.76
0.74
0.76
0.86
0.83
0.81
0.80
0.81
1.00
1.00
1.00
1.00
1.00
1.15
1.20
1.25
1.28
1.24
1.21
1.30
1.38
1.43
1.37
1.24
1.35
1.45
1.52
1.44
1.25
1.36
1.47
1.54
1.46
360 Hz 1 kHz 5 kHz 10 kHz & up
Complies with the EU Directive
2002/95/EC requirement
restricting the use of Lead (Pb),
Mercury (Hg), Cadmium (Cd),
Hexavalent chromium (Cr(VI)),
PolyBrominated Biphenyls
(PBB) and PolyBrominated
Diphenyl Ethers (PBDE).
Load Life:
Shelf Life:
10,000 h at full load at 85 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
500 h at 105 °C, capacitance, ESR and DCL, initial requirements
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864) 843-2277 • Fax: (864) 843-3800 • www.cde.com
MicroPython Hands-on (11) - Building the IDE environment for the control board
In order to lay a solid foundation and systematically learn MicroPython, I bought two control boards.This content is originally created by EEWORLD forum user eagler8 . If you want to reprint or use it...
eagler8 MicroPython Open Source section
Are the stm32F1** and stm32F2** firmware libraries the same?
As the title says,...
wonderglass stm32/stm8
Current amplifier circuit
If anyone has information on current amplifier circuits, please share it with me. Practical circuits are best. I have found several circuits, but the debugging results are not ideal. :handshake That's...
竹林中人 Analog electronics
Working principle of diode limiter circuit
[p=30, null, left][font=宋体][size=3][color=#000000] The most basic working state of a diode is conduction and cutoff. This characteristic can be used to form a limiting circuit. The so-called limiting ...
fish001 Analogue and Mixed Signal
One in one out project case
System design Each entrance and exit is managed by a computer. A computer is set up in the management office for authorization and management of entry and exit. The data is stored in the management of...
程序天使 Industrial Control Electronics
System beat problem
I have a question for you guys. Why is the CCLK system beat of 100MHZ 10ms? According to the calculation of system beat timer timing time = Fcclk/(STRRLOAD+1): Fcclk = 100MHZ The default value of STRR...
墨秋晓 NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1093  1266  1448  2401  301  23  26  30  49  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号