EEWORLDEEWORLDEEWORLD

Part Number

Search

325642U010JE1

Description
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 35 V, 1700 uF, THROUGH HOLE MOUNT
CategoryPassive components   
File Size323KB,4 Pages
ManufacturerETC
Download Datasheet Parametric View All

325642U010JE1 Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 35 V, 1700 uF, THROUGH HOLE MOUNT

325642U010JE1 Parametric

Parameter NameAttribute value
Maximum operating temperature125 Cel
Minimum operating temperature-55 Cel
negative deviation10 %
positive deviation75 %
Rated DC voltage urdc35 V
Processing package descriptionCAN, ROHS COMPLIANT
Lead-freeYes
EU RoHS regulationsYes
stateACTIVE
terminal coatingTIN OVER COPPER
Installation featuresTHROUGH HOLE MOUNT
Manufacturer Series325
capacitance1700 uF
packaging shapeCYLINDRICAL PACKAGE
Capacitor typeNON SOLID
Terminal shapeWIRE
equivalent series resistance63.8mohm
polarityPOLARIZED
ripple current1.2428A
leakage current121.9uA
Type 325/326,
–55 ºC to 125 ºC Long-Life, Switching Power Grade Radial
High Temperature and Ultra-Low ESR
The Types 325 and 326 are the ultra-wide-temperature, low-ESR
capacitors for switching power-supply outputs and automotive applications.
The 125 °C capability and exceptionally low ESRs enable high ripple-
current capability. With series inductance of 12 to 16 nH and ripple currents
to 27 amps one of these capacitors can save by replacing eight to ten of the
12.5 mm diameter capacitors routinely at the output of switching power
supplies. Type 325 has three leads for rugged, reverse-proof mounting, and
Type 326 has two leads
.
Highlights
2000 hour life test at 125 °C
Ripple Current to 27 amps
ESRs to 5 m
> 90% capacitance at –40 °C
Replaces multiple capacitors
Type 325
Type 326
Specifications
Operating Temperature:
Rated Voltage:
Capacitance:
Capacitance Tolerance:
Leakage Current:
Cold Impedance:
Ripple Current Multipliers:
–55 °C to 125 °C
6.3 to 63 Vdc –
880 µF to 46,000 µF
–10 +75%
≤0.5 √CV µA, 4 mA max, 5 minutes
–55 °C multiple of 25 °C Z ≤2.5 @ 120 Hz
≤20 from 20–100 kHz
Ambient Temperature
45ºC
1.39
120 Hz
see ratings
55ºC
1.3
65ºC
1.21
75ºC
1.11
85ºC
1.00
95ºC
0.88
105ºC
0.73
1 kHz
0.85
115ºC 125ºC
0.55
0.26
20-100 kHz
1.00
Frequency
360 Hz
0.76
400 Hz
0.77
Life Test:
Load Life:
Complies with the EU Directive
2002/95/EC requirement
restricting the use of Lead (Pb),
Mercury (Hg), Cadmium (Cd),
Hexavalent chromium (Cr(VI)),
PolyBrominated Biphenyls
(PBB) and PolyBrominated
Diphenyl Ethers (PBDE).
Shelf Life:
Outline Drawings
Vibration:
2000 h with rated voltage at 125 °C
∆ capacitance ± 10%
ESR 125 % of limit
DCL 100 % of limit
4000 h at full load at 85 °C
∆ capacitance ± 10%
ESR 200 % of limit
DCL 100 % of limit
500 h at 105 °C,
∆ capacitance ± 10%,
ESR 110% of limit,
DCL 200% of limit
10 to 55 Hz, 0.06” and 10 g max, 2 h each plane
CDM Cornell Dubilier
140 Technology Place
Liberty, SC 29657
Phone: (864)843-2277
Fax: (864)843-3800
www.cde.com
Can PWM DC-AC chopping achieve high-precision output?
PWM DC-AC complementary with dead zone and chopping, can high-precision PWM be used? Because there are fluctuations in the chopping process, is there any register counting during the chopping process?...
鹏飞公司 DSP and ARM Processors
A small question for a novice, looking for help
When I use platform builder 4.2 to customize the kernel, the following error always occurs. I am very depressed. I hope everyone can help me. I am new to embedded programming CVTRES : fatal error CVT1...
liaorentai Embedded System
Multiple porting solutions for μC/OS-II on LPC213X
μC/OS-II is a portable, deprivation-type real-time multitasking embedded system suitable for safety-critical applications. It is easy to learn and is very popular in engineering applications and embed...
笨笨尉 Embedded System
HelperA64 core board design summary
The summary is just to link several scattered posts together so that everyone can have a comparison and appreciate the progress and care of each design: First version: https://bbs.eeworld.com.cn/threa...
spacexplorer Embedded System
Please help me with the analog circuit problem
Hello everyone, my laboratory robot mainly uses a DC motor to drive climbing, but when going downhill, I want to use the reversible reaction of the DC motor to charge the battery. When the DC motor is...
hujian0809 Robotics Development
Please briefly explain the Gerber file
[url]http://jingyan.baidu.com/article/b87fe19e84fae5521935685e.html[/url] This Baidu tutorial is well written, but there are still some things I don’t understand, for example, in , there is a differen...
ZNF PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1860  1169  1425  585  1598  38  24  29  12  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号