Description
AC-DC Power Factor Correction Module, 2 Output, 250W, Hybrid, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size535KB,23 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LKP5742-7PD4B1 Overview

AC-DC Power Factor Correction Module, 2 Output, 250W, Hybrid, METAL, CASE K02, MODULE

LKP5742-7PD4B1 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage187 V
Nominal input voltage230 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage28.25 V
Minimum output voltage25.25 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output250 W
Fine-tuning/adjustable outputNO
Base Number Matches1
Cassette Style
AC-DC Converters
KP Series
250 Watt AC-DC Converters with PFC
Input voltage from 187...255 V AC
1 or 2 isolated outputs up to 56.5 V DC
4 kV AC I/O electric strength test voltage
• Power factor
>0.95,
harmonics
<IEC/EN61000-3-2
• Output power up to 280 Watt
• Input over- and undervoltage lock-out
• Efficient input filter and built-in surge and transient
suppression circuitry
• Fully isolated outputs
• Outputs open- and short-circuit proof
Safety according to IEC/EN 60950
LGA
KP Series
111
4.4"
3U
Summary
The KP series is an extension of the K series of AC-DC con-
verters with an increased output power level of up to 280 W
depending on the operating ambient temperature require-
ments. The KP converters are optimized for use in
230 V AC mains applications and feature high efficiency,
high reliability, low output voltage noise and excellent dy-
namic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occuring at the source lines. An input over- and
undervoltage lock-out curcuitry disables the outputs if the
input voltage is outside the specified range. The LKP types
include an inrush current limitation preventing circuit break-
ers and fuses from being damaged at switch-on.
The outputs are open- and short-circuit proof and are pro-
tected against overvoltages by means of a built-in suppres-
sor diode. The outputs can be inhibited by a logic signal
applied to the connector pin 18 (i). If the inhibit function is
not used pin 18 must be connected with pin 14 to enable
the outputs (fail safe).
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
80
3.2"
16 TE
168
6.6"
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950.
The case design allows operation up to an operating ambi-
ent temperature of 71°C with reduced output power. De-
pending on the ambient temperature requirements, how-
ever, the output power can be up to 280 W.
An internal temperature sensor generates an inhibit signal
which disables the outputs if the case temperature
T
C
ex-
ceeds the specified limit. The outputs are automatically re-
enabled when the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications. Especially for battery charger applica-
tions an external temperature sensor has been designed to
allow for temperature compensated battery charging.
The modules may either be plugged into 19" rack systems
according to DIN 41494 or be chassis mounted.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 14
Immunity to Environmental Conditions ........................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Description of Options .................................................... 20
Accessories .................................................................... 23
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 10
Edition 01/01.2001
1/23
Help with GPIO settings
I would like to ask you: I set the GPIO state to input, which is used to detect the high and low states of some current circuits. In addition to setting the corresponding GPIO state controller to "inp...
jiangyebula Embedded System
Show the process of WEBENCH design + negative 5v power supply design
Now some op amp chips use -5V to work. So to design a similar power supply 1. Fill in the design requirements2. Overall design3. Generate schematic4. Optimize the diagram...
william228 Analogue and Mixed Signal
Problems when installing STM8 software IAR
[color=#000000][font=宋体][size=5]When I first installed the program, I got the following error: Fatal Error[Cp001]: Copy protection check, No valid licens[/size][/font][font=宋体][size=5]e found for this...
歆玥 stm32/stm8
Suddenly I was caught by a bird.
A few days ago, due to some reasons, I didn't go to work on a weekday, so I went to the school. I went to the toilet. Suddenly I heard a sound. I turned around and saw that it was a magpie. It was sta...
ienglgge Talking
[TI's First Low Power Design Competition] Low Power Bluetooth Humidity Measurement
[i=s]This post was last edited by gkcn on 2014-12-24 22:46[/i] I'm sorry to post this so late. I've been busy with many things recently and have no time. This time, I actually planned to make a system...
gkcn Microcontroller MCU
Find the internal circuit of max2118
I'm studying the max2118 chip recently. Since I'm a beginner and do n't have much experience, is there anyone using it? Can you introduce the internal modules of this chip, the functions of each modul...
wwm101 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 597  454  1113  1352  2155  13  10  23  28  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号