800-011-02M12-37HN

Description
Circular Connector, 37 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size214KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

800-011-02M12-37HN Overview

Circular Connector, 37 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

800-011-02M12-37HN Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceNICKEL
Shell materialALUMINUM ALLOY
Housing size12
Termination typeCRIMP
Total number of contacts37
Base Number Matches1
A
B
C
In-Line
Rear Panel Jam Nut Mount
Square Flange Mount
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
Series 800
Series 800 “Mighty Mouse”
Original UNF Threaded Coupling
Series 800 Receptacles – Crimp Termination
Integral Band Platform
for direct attachment of a cable
shield using a
BAND-IT®
strap. Install a boot, or overmold
onto the band platform. An accessory thread is available
for attaching strain reliefs and backshells.
Three Shell Options:
Jam nut with o-ring for rear panel
mounting, square flange or in-line receptacle for free-hanging
cables.
HOW TO ORDER
Sample Part Number
80 0- 0 11
Series
-0 1
Shell Style
M
Shell Material /
Finish
C
6-4
Shell Size- Insert
Arrangement
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contacts
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
N
Shell Key
Position
N
Normal
-01
In-Line
800-010
Receptacle with
Banding Platform
-02
Square Flange
for Front or Rear
Mounting
5-3
Aluminum / Black
6-1
Anodize
6-4
M
6-7
Aluminum / Electroless
7-1
Nickel
7-10
NF
8-13
Aluminum / Cadmium
9-4
with Olive Drab
9-19
Chromate
10-26
ZN
12-2
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
12-37
X
Pos. X
P
Pin
Y
Pos. Y
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
Z
Pos. Z
800-011
Receptacle with
Accessory Thread
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
-07
Jam Nut for Rear
Panel Mounting
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
C-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
[Help] W5300 UDP cannot receive data
dsp controls W5300 to use UDP to send and receive data with PC. W5300 has no problem with UDP sending, but cannot receive UDP packets from PC. The code is as follows. When debugging in CCS4.2, rxlen (...
warcraftiii Embedded System
Infineon Tmall flagship store is giving away gifts!
In order to expand online purchasing channels, help developers accelerate innovation, and buy reliable Infineon components, Infineon has entered Tmall Now, click here to log in to Infineon Tmall flags...
eric_wang Talking
Signal Generator Professional Knowledge Q&A
I hope it will be useful to everyone....
terrykgm MCU
Detailed explanation of digital filtering using single chip microcomputer
[size=4][color=#000000][backcolor=white] The main function of a single-chip microcomputer is to control peripheral devices and realize certain communications and data processing. However, in certain s...
Jacktang Microcontroller MCU
WinCE USB driver, ported from 5.0 to 4.2. What should I pay attention to?
I need to port the USB to serial port driver from ce5.0 to 4.2 system, and the time requirement is very tight. Is it difficult to port? What issues should I pay attention to? Thank you!...
yrfpla Embedded System
Why can't the application access address 0?
Why can't the application access address 0 (virtual address)? Aren't all virtual addresses 0x00000000 to 0xBFFFFFFF its own?...
gezich210 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2401  2086  2330  377  2636  49  42  47  8  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号