PB15W-90-1F

Description
15A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET
CategoryThe connector    The connector   
File Size272KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance  
Download Datasheet Parametric View All

PB15W-90-1F Overview

15A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET

PB15W-90-1F Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; CSA
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings15A, 115/250VAC
Manufacturer's serial numberPB
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
Base Number Matches1
POWER LINE FILTER
PB Series
STRAIGHT, SNAP-IN/FLANGE MOUNT FILTER WITH IEC 60320
AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
50.1
30.3
22.5
40.0
28.5
4-R5
21.6
2-
3.3
40.0
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.9
47.4
41.8
54.0
FEATURES
The PB series, similar to PA and PASP series, offers filters with
IEC connector providing effective equipment protection of
line-to-ground noise up to 15 Amp, 250VAC. The compact
design filter with low leakage current is well suited for
applications that require strict national and international
emission standards. These filters are also available for
Medical application and offer extremely low Leakage current
to comply with UL544, UL2601 and CSA22.2 standards.
A ground choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
G
28.3
20.6
31.0
24.0
21.9
4-R2
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
28.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
3.6
51.8
40.9
28.3
20.6
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
7
[Show off] My DIY 0V voltage regulator
Purely handmade, a bit ugly :lol There are two potentiometers in the front, one for adjusting the output voltage and the other for adjusting the current limit. The output voltage is OK, I am quite sat...
dontium Analogue and Mixed Signal
What is the difference between BUSHound and virtual serial port?
In the example of debugging the virtual serial port, when the serial port debugging tool is used to send 64 bytes of data from the PC, the STM receives 128 data. However, when the same 64 bytes are se...
markov stm32/stm8
How is the embedded navigation system designed?
As the technological development continues to accelerate, more and more people are forced to work in a tight time and place. As the speed of urbanization continues to expand, not only the traffic netw...
灞波儿奔 Microcontroller MCU
About the msp-exp430fr5739 bought on Taobao. (The problem has been solved, thank you all~)
I bought an msp-exp430fr5739 development board on Taobao. I encountered a problem. I think there is something wrong with the development board. Of course, it is also possible that my skills are not go...
奥利奥奥 Microcontroller MCU
Learning CCS v5
I'm begging for a detailed Chinese tutorial on CCS v5! It would be even better if there were video resources!...
1372794486 Microcontroller MCU
ZigBee Communication Issues
A routing node is bound to multiple nodes. I want this routing node to send a command to these nodes. How should I send it and how should I write the destination address?...
mgf_xuexi RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1691  525  2644  1025  1833  35  11  54  21  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号