EEWORLDEEWORLDEEWORLD

Part Number

Search

TR2/S506-80MAV

Description
Electric Fuse, Time Delay Blow, 0.08A, 250VAC, 35A (IR), Through Hole
CategoryCircuit protection    Circuit protection   
File Size200KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

TR2/S506-80MAV Overview

Electric Fuse, Time Delay Blow, 0.08A, 250VAC, 35A (IR), Through Hole

TR2/S506-80MAV Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Fusing characteristicsTIME DELAY
body height21.1 mm
Body length or diameter5.54 mm
Circuit protection typeELECTRIC FUSE
JESD-609 codee3
Joule integral nominal
Manufacturer's serial numberS506
Installation featuresTHROUGH HOLE
method of packingTAPE AND REEL
physical size5.54mm x 21.1mm
Rated breaking capacity35 A
Rated current0.08 A
Rated voltage (AC)250 V
GuidelineBSI; CCC; CSA; IEC; IMQ; MITI; SEMKO; UL; VDE
surface mountNO
Terminal surfaceTIN
Terminal shapePIN WIRE
Base Number Matches1
5mm x 20mm Fuses
S506 Series, Time Delay, Glass Tube
Description
• Time delay, low breaking capacity
• Optional axial leads available
• 5mm x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Designed to IEC 60127-2 (32mA-10A)
S506 ELECTRICAL CHARACTERISTICS
2.1 In
2.75 In
4 In
10 In
In
max
min
max
min
max
min
max
32mA-100mA 2 min 200 ms 10 sec 40 ms 3 sec 10 ms 300 ms
125mA-6.3A 2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
8A-15A
2 min 600 ms 10 sec 150 ms 3 sec 20 ms 300 ms
RoHS
2002/95/EC
Dimensions
Drawing Not to Scale
Agency Information
• UL Recognized Card: (32mA-15A) Guide JDYX2,
File E19180
• CSA Component Acceptance: File 53787
• cURus Recognition: Guide JDYX8, File E19180
• SEMKO Approval, 32mA-10A
• VDE Approval, 32mA-10A
• BSI Approval, 32mA-10A
• IMQ Approval, 32mA-10A
• MITI Approval, 32mA-6.3A
• CCC Approval, 32mA-6.3A
Ordering
• Specify packaging, product, and option code
• For -R option, drop mA or A from product code
(i.e. S506-2-R)
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
Interrupting Rating
at Rated Voltage (50Hz)
AC
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
35A
40A
50A
63A
80A
100A
125A
125A
• Ratings above 6.3A have a 0.8mm diameter lead
• With TR2 packaging code, lead wire length is 19.05mm
SPECIFICATIONS
Product Code
S506-32mA
S506-40mA
S506-50mA
S506-63mA
S506-80mA
S506-100mA
S506-125mA
S506-160mA
S506-200mA
S506-250mA
S506-315mA
S506-400mA
S506-500mA
S506-630mA
S506-800mA
S506-1A
S506-1.25A
S506-1.6A
S506-2A
S506-2.5A
S506-3.15A
S506-4A
S506-5A
S506-6.3A
S506-8A
S506-10A
S506-12.5A
S506-15A
Typical DC
Cold Resistance
(ohms)*
21.0
13.90
9.24
6.96
4.42
2.74
1.97
1.27
1.00
0.640
0.450
0.308
0.183
0.186
0.128
0.062
0.045
0.038
0.028
0.023
0.017
0.012
0.008
0.008
0.006
0.004
0.004
0.004
Minimum
Pre-Arching I
2
t
(A
2
Sec) AC†
0.0014
0.0034
0.006
0.012
0.015
0.022
0.034
0.052
0.078
0.17
0.41
0.61
0.67
1.0
2.2
2.7
6.7
9.7
15
25
51
88
150
214
192
420
812
1029
Typical
Voltage
Drop (mV)‡
1050
920
800
760
580
490
390
320
340
270
250
210
140
150
75
80
70
70
68
68
66
66
66
60
55
54
45
73
Traditional Ferrule Fuses - Ferrule Type
* DC Cold Resistance (Measured at <10% of rated current)
† Minimum Pre-Arching I
2
t (Measured at 10 In and rated voltage)
‡ Typical Voltage Drop (Voltage drop was measured at 20°C ambient temperature at rated current)
OC-66
SDIO mode initialization fails
Hardware platform: EK-STM3210ESoftware platform: uVision4program uses V2.02 library, the program runs to Status = SD_Init(); error returns 0X03. The serial port can communicate normally. The following...
jielii stm32/stm8
AC is connected to the RS485 line? I still can't find the reason?
AC is connected to the RS485 line? Haven't found the reason yet? Recently, I tested that all the components on an RS485 line were damaged, and the chip was broken. Finally, I found that AC was connect...
adherevictor Test/Measurement
Keithley Series 3700 Setup and Communication
There are two options : either run individual ICL commands ( similar to sending individual SCPI commands ) or write test scripts in the Test Script Language. The Test Script Language ( TSL ) is a prog...
Jack_ma Test/Measurement
STM32 shutdown mode wake up dead
Recently, when using the key interrupt to wake up in the STM32 shutdown mode, pressing the key repeatedly will cause a freeze. After multiple tests, it is found that the interrupt can be entered befor...
wjd85 stm32/stm8
How does Freescale 56F8013 count the internal clock?
I can't find a way to set the timer to count the internal clock in CodeWarrior. I used to be able to directly query the value of the self-increment register when learning microcontrollers, but I can't...
幻想的火焰 NXP MCU
STM32 CAN is not working. Is it possible to remove the driver chip and directly connect the CAN TX of two STM32 chips to RX and RX to TX?
The STM32F013 chip CAN cannot be debugged. I want to confirm whether there is a problem with the hardware. I want to remove the CAN driver chip and directly connect the CAN TX of the two STM32 chips t...
wuyueye stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 505  947  2909  841  1327  11  20  59  17  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号