Part Number

Search

M83723/82W12124

Description
MIL Series Connector, 12 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle
CategoryThe connector    The connector   
File Size183KB,1 Pages
ManufacturerAero-Electric Connector
Websitehttps://www.aero-electric.com/index.html
Download Datasheet Parametric View All

M83723/82W12124 Overview

MIL Series Connector, 12 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle

M83723/82W12124 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codecompliant
Other featuresSTANDARD: MIL-DTL-83723 SERIES III, COMPATIBLE CONTACT: M39029/5-115
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Environmental characteristicsCORROSION RESISTANT; ENVIRONMENT RESISTANT; FLUID RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial numberM83723
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceCADMIUM PLATED
Shell materialALUMINUM ALLOY
Housing size12
Termination typeCRIMP
Total number of contacts12
Base Number Matches1
M83723/82, 83
Wall Mounting Receptacle
AE83382, 83
Threaded Coupling, Crimp Removable, Rear Release
1.340(34.04) MAX
CLASSES: “N” & “S” ONLY
A
B
MASTER
KEYWAY
1.248(31.70)
MAX
.072(1.83)
.728(18.49)
.052(1.32)
.708(17.98)
.290(7.37) MIN
FULL THREAD
.190(4.83) GROMMET
.130(3.30) EXTENSION
3 ACCESORY TEETH
EQUALLY SPACED
.290(7.37) MIN FULL THREAD
.160(4.06) GROMMET
.010(0.25) EXTENSION
MAX
GROMMET
F
MAX
GROMMET
F
4 MINOR KEYWAYS
D
MATING THREAD
4x
C
MOUNTING HOLES
FULL MATE
INDICATOR
COLOR: RED
E
ACCESSORY THREAD
BLUE COLOR BANDS
H
No. OF TEETH
CLASSES: “N” & “S” ONLY
E
ACCESSORY THREAD
PANEL THICKNESS:
.125(3.18) MAX
Page 93
Page 104
Pages 107 108
,
Page 87
Page 106
Page 102
MIL–DTL–
83723 S III
Completed Part Number
Contacts, Sealing Plugs and Tools
Insert Arrangements
Performance Specifications
Insert Availability and Contact Information
Polarization
A
Shell
Size
8
10
12
14
16
18
20
22
24
28
±.005
inch
.812
.937
1.031
1.125
1.250
1.343
1.437
1.562
1.703
2.000
±.13
mm
20.62
23.80
26.19
28.58
31.75
34.11
36.50
39.67
43.26
50.80
inch
.594
.719
.812
.906
.969
1.062
1.156
1.250
1.375
1.562
B
(TP)
mm
15.09
18.26
20.62
23.01
24.61
26.97
29.36
31.75
34.93
39.67
+.005
-.004
inch
.120
.120
.120
.120
.120
.120
.120
.120
.149
.149
C
+.13
-.10
mm
3.05
3.05
3.05
3.05
3.05
3.05
3.05
3.05
3.78
3.78
D
Mating Thread
Class 2A
9/16-24UNEF
11/16-24UNEF
7/8-20UNEF
15/16-20UNEF
1-1/16-18UNEF
1-3/16-18UNEF
1-5/16-18UNEF
1-7/16-18UNEF
1-9/16-18UNEF
1-13/16-16UN
E
Accessory Thread
Class 2A
1/2-20UNF
5/8-24UNEF
3/4-20UNEF
7/8-20UNEF
1-20UNEF
1-1/16-18UNEF
1-3/16-18UNEF
1-5/16-18UNEF
1-7/16-18UNEF
1-3/4-18UNS
F
Maximum
inch
.305
.405
.531
.665
.790
.869
.994
1.119
1.244
1.475
mm
7.75
10.29
13.49
16.89
20.07
22.07
25.25
28.42
31.60
37.47
H
No. of
Teeth
12
15
21
24
30
33
36
39
42
54
www.conesys.com
– 94 –
sales
@
aero-electric.com
Excuse me, how does the electric meter with both steps and peaks and valleys work?
Excuse me, how does the electric meter with both steps and peaks and valleys work?...
一沙一世 stm32/stm8
About the problem of MSP430's built-in IIC
According to the manual, when I use MSP430 as a master receiver, if I want to end the process after receiving the next data during an interrupt, I should write STP after reading BUF. In this case, wil...
zsh1995 Microcontroller MCU
A case study on low power design
[font=微软雅黑][color=#ff0000][backcolor=rgb(204, 232, 207)] [img]http://www.miractech.com/Upload/20151123001530yZDR.png[/img] [img]http://www.miractech.com/Upload/20151123001531KcEb.png[/img] [/backcolor...
qewnja Analog electronics
BMC Power Aegis Next-Generation Intelligent Firewall
BMC Power Aegis new generation intelligent firewall-----the only security gateway in China that corresponds to the level. Multiple security modules such as TMA (traffic control) and AMS (application m...
林临磷 Embedded System
Test your knowledge of MCU --- MCU basic knowledge test questions
[align=left]I. Fill in the blanks (15 points, 1 point for each blank) [/align][align=left]1. The P0-P4 ports of the MCS-51 microcontroller are all parallel I/O ports. In addition to data input and out...
tiankai001 MCU
Switching circuit!
There are two loads: one is a motor and the other is a music IC. A three-stage switch is required to be used as the power switch for the two loads. Please use discrete components to design a switching...
xiaoyuanlu Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2145  2283  756  1108  2364  44  46  16  23  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号