803-003-07M5-3SY

Description
Circular Connector, 3 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size263KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance  
Download Datasheet Parametric View All

803-003-07M5-3SY Overview

Circular Connector, 3 Contact(s), Aluminum Alloy, Female, Crimp Terminal, Receptacle,

803-003-07M5-3SY Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGlenair
Reach Compliance Codecompliant
Factory Lead Time17 weeks 1 day
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceELECTROLESS NICKEL
Shell materialALUMINUM ALLOY
Housing size5
Termination typeCRIMP
Total number of contacts3
Base Number Matches1
Series 803 “Mighty Mouse”
¼ Turn Bayonet Coupling
Series 803 Bayonet Crimp Receptacles
A
B
F
D
E
6–7
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
Push-To-Mate, ¼ Turn to Lock.
These quick-mating connectors feature
bayonet pins on the receptacle. Simply
push the connectors together, then
rotate the plug coupling nut 90° to lock
the connectors together.
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, elliptical flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose the integral
band platform for direct attachment
of a cable shield. Install a heat-shrink
boot, or overmold directly onto the
band platform. An accessory thread is
available for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 3 - 003
Series
803-003
Receptacle with
Banding Platform
for Direct
Attachment of
Cable Shield and
Overmold
-0 7
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
S
Contact Type
P
Pin
N
Shell Key
Position
N
Normal
Alternate
Key
Positions:
-07
Jam Nut
S
Socket
Standard #23 contacts
accept #22 through
#28 AWG wire. Special
contacts for #26 to #30
AWG are available. Use
the following contact
codes to specify these
contacts:
M
Aluminum / Electroless
Nickel
NF
-02
Flange Mount
Aluminum / Cadmium
with Olive Drab
Chromate
X
Y
Z
ZN
803-004
Receptacle with
Rear Accessory
Thread
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
G
Pin #2630
ZNU
-01
In-Line
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
H
Socket #2630
Z1
Stainless Steel /
Passivated
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
F-5
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Series 803
F
G
H
J
K
L
M
Simple remote control switch production
The characteristic of this remote control switch is that it does not require a special remote control mobile phone, and can be operated by the color TV remote control at home. It can very conveniently...
程序天使 RF/Wirelessly
Cable TV Management System Graduation Thesis
Please help me with the software, thanks...
xiaohuazhong5 Power technology
I'm a newbie and I don't understand the simple macro definition. Please help me.
#define _ADD_STR(a, b) a##b These a and b are parameters. What about this##...
smallbird Microcontroller MCU
I have compiled a set of methods for forming logic gate circuits using triodes. Universities generally don't teach this.
[color=#008000]Introduction: Sometimes we only need to implement a simple logic when building a circuit, but using a 4-gate integrated circuit to design it is too expensive and takes up too much space...
奋斗吧小鱼儿 Analog electronics
Single power supply to dual power supply
Dear experts: I am working on a design that uses 2 lithium batteries for power supply. I need to replace the power supply with a positive and negative dual power supply. This is my idea. I hope you ca...
leid333 Power technology
How to read circuit diagrams Recommended resources 5. Understanding mobile phone circuit diagrams
[align=center][size=5]How to read circuit diagrams Recommended resources V. [color=rgb(0, 0, 0)][backcolor=rgb(237, 235, 235)][font=微软雅黑]Understand mobile phone circuit diagrams[/font][/backcolor][/co...
tiankai001 Download Centre

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1372  871  2825  1204  509  28  18  57  25  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号