EEWORLDEEWORLDEEWORLD

Part Number

Search

FBP-700

Description
Electric Fuse, 700A, 700VAC, 700VDC, 200000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size70KB,3 Pages
ManufacturerEaton
Download Datasheet Parametric Compare View All

FBP-700 Overview

Electric Fuse, 700A, 700VAC, 700VDC, 200000A (IR), Inline/holder,

FBP-700 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
body height81 mm
Body length or diameter79.4 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size79.4mm x 81mm
Rated breaking capacity200000 A
Rated current700 A
Rated voltage (AC)700 V
Rated voltage (DC)700 V
GuidelineUL
surface mountNO
Terminal shapeTAB/BLADE
Base Number Matches1
Bussmann
®
Semiconductor Fuses
700 Volts AC/DC, 35-1000 Amps
FBP
CATALOG SYMBOL: FBP
700V AC, 700V DC
INTERRUPTING RATING 200,000 AMPERES
RMS SYMMETRICAL
U.L. RECOGNIZED
(GUIDE #JFHR2, FILE # E56412)
Catalog Numbers
FBP-35
FBP-40
FBP-50
FBP-60
FBP-70
FBP-80
FBP-90
FBP-100
FBP-125
FBP-150
FBP-175
FBP-200
FBP-250
FBP-300
FBP-350
FBP-400
FBP-450
FBP-500
FBP-600
FBP-700
FBP-800
FBP-900
FBP-1000
Ultra High Degree of Current Limitation and Low I
2
t.
• The heat energy of even low-level fault currents can quickly
destroy a semiconductor device.
* Buss FW type fuse limits peak let-thru current to a level
which is a fraction of the potential available short-circuit peak
current.
• Fast speed-of-response to build-up of short-circuit current
and the quickly decaying short-circuit current as the fuse
suppresses internal arcing together can limit the I
2
t let-thru to
values substantially lower than the I
2
t withstand of the semi-
conductor device.
Current Rating.
• Current rating is given in AC (rms) for an ambient tempera-
ture of 20ºC (68ºF).
• Although these fuses can be operated at 100% of rating,
good design practice dictates some derating (i.e. for ambient
temperature), typically this is 20%.
Voltage Rating.
• Rated voltage of Semiconductor fuses is given in terms of
A.C. operation, 60Hz.
• When used in D.C. circuits no voltage derating is required
provided the minimum interrupting capability is eight times
the fuse rating and the time constant does not exceed those
specified in U.L. 198L.
Total Clearing I
2
t.
• Maximum values of total clearing I
2
t are obtained at the rated
A.C. voltage, an arcing angle between 60º and 90º, at an
available symmetrical rms current of 100,000 amperes, and
at a power factor of less than 15%.
Arc Voltage.
• The arc voltage which develops across a fuse when it is
clearing a fault current must always exceed the system volt-
age.
• This arc voltage may reach a value which is twice that of the
system applied voltage.
12-17-98
SB98107
Rev. A
Form No. FBP
Page 1 of 3
BIF Doc #720041

FBP-700 Related Products

FBP-700
Description Electric Fuse, 700A, 700VAC, 700VDC, 200000A (IR), Inline/holder,
Is it Rohs certified? incompatible
Maker Eaton
Reach Compliance Code compliant
ECCN code EAR99
body height 81 mm
Body length or diameter 79.4 mm
Circuit protection type ELECTRIC FUSE
Installation features INLINE/HOLDER
physical size 79.4mm x 81mm
Rated breaking capacity 200000 A
Rated current 700 A
Rated voltage (AC) 700 V
Rated voltage (DC) 700 V
Guideline UL
surface mount NO
Terminal shape TAB/BLADE
Base Number Matches 1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 135  1602  1347  2830  403  3  33  28  57  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号